| 39697.1 |
01. 1500 .032 Alum Roof Panel / B-Deck |
MRS System 1500 1-1/2" Mechanically Seamed 0.032" Aluminum 16" Max. Width Roof Panel over B-Deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +0/-56 Other: Please see installation instructions and evaluation report for additional details and limits of use |
Installation Instructions FL39697_R2_II_1500-Alum-BDeck.pdf Verified By: Lucas A. Turner PE #58201 Created by Independent Third Party: Yes Evaluation Reports FL39697_R2_AE_EvalReport-1500-Alum-BDeck.pdf Created by Independent Third Party: Yes |
|
|
| 39697.2 |
02. 1500 24 ga Steel Roof Panel / B-Deck |
MRS System 1500 1-1/2" Mechanically Seamed 24 ga Galvalume Steel 16" Max. Width Roof Panel over B-Deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +0/-71 Other: Please see installation instructions and evaluation report for additional details and limits of use |
Installation Instructions FL39697_R2_II_1500-Stl-BDeck.pdf Verified By: Lucas A. Turner PE #58201 Created by Independent Third Party: Yes Evaluation Reports FL39697_R2_AE_EvalReport-1500-Stl-BDeck.pdf Created by Independent Third Party: Yes |
|
|
| 39697.3 |
03. 1500 24 ga Steel Roof Panel / Plywood |
MRS System 1500 1-1/2" Mechanically Seamed 24 ga Galvalume Steel 16" Max. Width Roof Panel over Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +0/-131 Other: Please see installation instructions and evaluation report for additional details and limits of use, and Design Pressures at various clip spacing. |
Installation Instructions FL39697_R2_II_1500-Stl-Ply.pdf Verified By: Lucas A. Turner PE #58201 Created by Independent Third Party: Yes Evaluation Reports FL39697_R2_AE_EvalReport-1500-Stl-Ply.pdf Created by Independent Third Party: Yes |
|
|
| 39697.4 |
04. 2000 .040 Alum Roof Panel / B-Deck |
MRS System 2000 1-3/4" Snaplock 0.040" Aluminum 16" Max. Width Roof Panel over B-Deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +0/-63.5 Other: Please see installation instructions and evaluation report for additional details and limits of use |
Installation Instructions FL39697_R2_II_2000-Alum-BDeck.pdf Verified By: Lucas A. Turner PE #58201 Created by Independent Third Party: Yes Evaluation Reports FL39697_R2_AE_EvalReport-2000-Alum-BDeck.pdf Created by Independent Third Party: Yes |
|
|
| 39697.5 |
05. 2000 .040 Alum Roof Panel / Plywood |
MRS System 2000 1-3/4" Snaplock 0.040" Aluminum 16" Max. Width Roof Panel over 1/2" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +0/-101 Other: Please see installation instructions and evaluation report for additional details and limits of use |
Installation Instructions FL39697_R2_II_2000-Alum-Ply.pdf Verified By: Lucas A. Turner PE #58201 Created by Independent Third Party: Yes Evaluation Reports FL39697_R2_AE_EvalReport-2000-Alum-Ply.pdf Created by Independent Third Party: Yes |
|
|
| 39697.6 |
06. 2000 24 ga Steel Roof Panel / B-Deck |
MRS System 2000 1-3/4" Snaplock 24 ga Galvalume Steel 16" Max. Width Roof Panel over B-Deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +0/-63.5 Other: Please see installation instructions and evaluation report for additional details and limits of use |
Installation Instructions FL39697_R2_II_2000-Stl-BDeck.pdf Verified By: Lucas A. Turner PE #58201 Created by Independent Third Party: Yes Evaluation Reports FL39697_R2_AE_EvalReport-2000-Stl-BDeck.pdf Created by Independent Third Party: Yes |
|
|
| 39697.7 |
07. 2000 24 ga Steel Roof Panel / Plywood |
MRS System 2000 1-3/4" Snaplock 24 ga Galvalume Steel 16" Max. Width Roof Panel over 1/2" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +0/-78.5 Other: Please see installation instructions and evaluation report for additional details and limits of use |
Installation Instructions FL39697_R2_II_2000-Stl-Ply.pdf Verified By: Lucas A. Turner PE #58201 Created by Independent Third Party: Yes Evaluation Reports FL39697_R2_AE_EvalReport-2000-Stl-Ply.pdf Created by Independent Third Party: Yes |
|
|
| 39697.8 |
08. 2500 .032 Alum Roof Panel / B-Deck |
MRS System 2500 2" Mechanically Seamed 0.032" Aluminum 16" Max. Width Roof Panel over B-Deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +0/-63.5 Other: Please see installation instructions and evaluation report for additional details and limits of use, and Design Pressures at various clip spacing. |
Installation Instructions FL39697_R2_II_2500-Alum-BDeck.pdf Verified By: Lucas A. Turner PE #58201 Created by Independent Third Party: Yes Evaluation Reports FL39697_R2_AE_EvalReport-2500-Alum-BDeck.pdf Created by Independent Third Party: Yes |
|
|
| 39697.9 |
09. 2500 .032 Alum Roof Panel / Plywood |
MRS System 2500 2" Mechanically Seamed 0.032" Aluminum 16" Max. Width Roof Panel over 1/2" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +0/-131 Other: Please see installation instructions and evaluation report for additional details and limits of use, and Design Pressures at various clip spacing. |
Installation Instructions FL39697_R2_II_2500-Alum-Ply.pdf Verified By: Lucas A. Turner PE #58201 Created by Independent Third Party: Yes Evaluation Reports FL39697_R2_AE_EvalReport-2500-Alum-Ply.pdf Created by Independent Third Party: Yes |
|
|
| 39697.10 |
10. 2500 24 ga Steel Roof Panel / B-Deck |
MRS System 2500 2" Mechanically Seamed 24 ga Galvalume Steel 16" Max. Width Roof Panel over B-Deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +0/-63.5 Other: Please see installation instructions and evaluation report for additional details and limits of use, and Design Pressures at various clip spacing. |
Installation Instructions FL39697_R2_II_2500-Stl-BDeck.pdf Verified By: Lucas A. Turner PE #58201 Created by Independent Third Party: Yes Evaluation Reports FL39697_R2_AE_EvalReport-2500-Stl-BDeck.pdf Created by Independent Third Party: Yes |
|
|
| 39697.11 |
11. 2500 24 ga Steel Roof Panel / Plywood |
MRS System 2500 2" Mechanically Seamed 24 ga Galvalume Steel 16" Max. Width Roof Panel over 1/2" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +0/-101 Other: Please see installation instructions and evaluation report for additional details and limits of use, and Design Pressures at various clip spacing. |
Installation Instructions FL39697_R2_II_2500-Stl-Ply.pdf Verified By: Lucas A. Turner PE #58201 Created by Independent Third Party: Yes Evaluation Reports FL39697_R2_AE_EvalReport-2500-Stl-Ply.pdf Created by Independent Third Party: Yes |
|
|
| 39697.12 |
12. 2500 .040 Alum Roof Panel / Purlins |
MRS System 2500 2" Mechanically Seamed 0.040" Aluminum 15-7/8" Max. Width Roof Panel over Purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: Please see installation instructions and evaluation report for additional details and limits of use, and Design Pressures at various purlin spacing. |
Installation Instructions FL39697_R2_II_2500-Alum-Purlin.pdf Verified By: Lucas A. Turner PE #58201 Created by Independent Third Party: Yes Evaluation Reports FL39697_R2_AE_EvalReport-2500-Alum-Purlins.pdf Created by Independent Third Party: Yes |
|
|
| 39697.13 |
13. 2500 24 ga Steel Roof Panel / Purlins |
MRS System 2500 2" Mechanically Seamed 24 ga Galvalume Steel 15-7/8" Max. Width Roof Panel over Purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: Please see installation instructions and evaluation report for additional details and limits of use, and Design Pressures at various purlin spacing. |
Installation Instructions FL39697_R2_II_2500-Stl-Purlin.pdf Verified By: Lucas A. Turner PE #58201 Created by Independent Third Party: Yes Evaluation Reports FL39697_R2_AE_EvalReport-2500-Stl-Purlins.pdf Created by Independent Third Party: Yes |
|
|
| 39697.14 |
14. Multi-Rib 26 ga Steel Roof Panel / Plywood |
14. MRS Multi-Rib 26 ga Galvalume Steel 36" Max. Width Roof Panel over Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: Please see installation instructions and evaluation report for additional details and limits of use, and Design Pressures at various anchor spacing. |
Installation Instructions FL39697_R2_II_MRib-Stl-Ply.pdf Verified By: Lucas A. Turner PE #58201 Created by Independent Third Party: Yes Evaluation Reports FL39697_R2_AE_EvalReport-MultiRib-Stl-Ply.pdf Created by Independent Third Party: Yes |