Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL1421-R8
Application Type Editorial Change
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Wayne-Dalton, a division of Overhead Door Corporation
Address/Phone/Email 3395 Addison Drive
Pensacola, FL 32514
(330) 763-8121
dkornish@wayne-dalton.com
 
Authorized Signature Tyler Day
tyler_day@overheaddoor.com
 
Technical Representative Tyler Day
Address/Phone/Email 2501 S State Hwy. 121
Suite 200
Lewisville, TX 75067
(469) 549-7039
tyler_day@overheaddoor.com
 
Quality Assurance Representative Aaron Richardson
Address/Phone/Email 14512 Lincoln Way E
Dalton, OH 44618
(330) 828-3388
Aaron_Richardson@wayne-dalton.com
 
Category Exterior Doors
Subcategory Roll-Up Exterior Door Assemblies
 
Compliance Method Test Report
 
Testing Lab Architectural Testing, Inc. (an Intertek company) - York, PA
Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date 12/31/2026
Validated By John E. Scates, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL1421_R8_COI_Cert_of_Ind_Scates_2020_WDs.pdf
FL1421_R8_COI_COI - ATI.pdf
FL1421_R8_COI_HET Letter Independ.pdf
FL1421_R8_COI_Wayne_Dalton_Test_Report_Expiration_Letter.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ANSI/DASMA 1082017
TAS 2011994
TAS 2021994
TAS 2031994
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL1421_R8_Equiv_Equivalence of Standards_s.pdf
 
 
 
 
Product Approval Method Method 1 Option B
 
Date Submitted 08/15/2024
Date Validated 08/25/2024
Date Pending FBC Approval 08/28/2024
Date Approved 10/15/2024
 
Summary of Products
FL # Model, Number or Name Description
1421.1 DS 350 Commercial Sheet Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +37/-37
 Other: Round panel profile. 10' wide. Steel, concrete, and grout-filled CMU jambs.
Installation Instructions
 FL1421_R8_II_035-0015_035-0016.pdf
 Verified By: John E. Scates, P.E. FL 51737
Test Reports
 PTID_1421_R1_T_ATI 01-46385-04.pdf
1421.2 DS 350 Commercial Sheet Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +28/-28
 Other: Round panel profile. 12' wide. Steel, concrete, and grout-filled CMU jambs.
Installation Instructions
 FL1421_R8_II_035-0014_035-0016.pdf
 Verified By: John E. Scates, P.E. FL 51737
Test Reports
 FL1421_R8_TR_ATI 01-46385-05.pdf
1421.3 DS 350 Commercial Sheet Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +28/-28
 Other: Round panel profile. 16' wide. Steel, concrete, and grout-filled CMU jambs.
Installation Instructions
 FL1421_R8_II_035-0013_035-0016.pdf
 Verified By: John E. Scates, P.E. FL 51737
Test Reports
 FL1421_R8_TR_ATI 01-46385-06.pdf
1421.4 DS 350 Commercial Sheet Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +44/-44
 Other: Square panel profile. 10' wide. Steel, concrete, and grout-filled CMU jambs.
Installation Instructions
 FL1421_R8_II_035-011_035-0012.pdf
 Verified By: John E. Scates, P.E. FL 51737
Test Reports
 FL1421_R8_TR_ATI 01-46385-01.pdf
1421.5 DS 350 Commercial Sheet Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +40/-40
 Other: Square panel profile. 12' wide. Steel, concrete, and grout-filled CMU jambs.
Installation Instructions
 FL1421_R8_II_035-0010_035-0012.pdf
 Verified By: John E. Scates, P.E. FL 51737
Test Reports
 FL1421_R8_TR_ATI 01-46385-02.pdf
1421.6 DS 350 Commercial Sheet Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +34/-34
 Other: Square panel profile, 16' wide. Steel, concrete, and grout-filled CMU jambs.
Installation Instructions
 FL1421_R8_II_035-0009_035-0012.pdf
 Verified By: John E. Scates, P.E. FL 51737
Test Reports
 FL1421_R8_TR_ATI 01-46385-03.pdf
1421.7 DS 75 Commercial Sheet Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +34/-34
 Other: Square panel profile, 10' wide. Steel, concrete, and grout-filled CMU jambs.
Installation Instructions
 FL1421_R8_II_035-0007_035-0008.pdf
 Verified By: John E. Scates, P.E. FL 51737
Test Reports
 FL1421_R8_TR_ATI 01-46384-01.pdf
1421.8 DS 75 Commercial Sheet Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +30/-34
 Other: Round panel profile, 10' wide. Steel, concrete, and grout-filled CMU jambs.
Installation Instructions
 FL1421_R8_II_701-0542_701-0543_701-0544.pdf
 Verified By: John E. Scates, P.E. FL 51737
Test Reports
 FL1421_R8_TR_HETI-01-1117-1118-T111-Full.pdf
1421.9 Models 800 & 800C (also includes HC & ADV Models) Commercial Rolling Steel Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +31/-31
 Other: Flat or insulated slat. 16' wide. Steel, concrete, and grout-filled CMU jambs.
Installation Instructions
 FL1421_R8_II_035-0003.pdf
 Verified By: John E. Scates, P.E. FL 51737
Test Reports
 FL1421_R8_TR_ATI 01-46389-02.pdf
1421.10 Models 800 & 800C (also includes HC & ADV Models) Commercial Rolling Steel Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +37/-37
 Other: Flat or insulated slat. 16' wide. Steel, concrete, and grout-filled CMU jambs.
Installation Instructions
 FL1421_R8_II_035-0004.pdf
 Verified By: John E. Scates, P.E. FL 51737
Test Reports
 FL1421_R8_TR_ATI 01-46389-03.pdf
1421.11 Models 800 & 800C (also includes HC & ADV Models) Commercial Rolling Steel Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +37/-37
 Other: Flat or insulated slat. 22' wide. Steel, concrete, and grout-filled CMU jambs.
Installation Instructions
 FL1421_R8_II_035-0006.pdf
 Verified By: John E. Scates, P.E. FL 51737
Test Reports
 FL1421_R8_TR_ATI 01-46389-04.pdf
1421.12 Models 800 & 800C (also includes HC & ADV Models) Commercial Rolling Steel Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +47/-47
 Other: Flat or insulated slat. 10' wide. Steel, concrete, and grout-filled CMU jambs.
Installation Instructions
 FL1421_R8_II_035-0002.pdf
 Verified By: John E. Scates, P.E. FL 51737
Test Reports
 FL1421_R8_TR_ATI_01-46388-01.pdf
1421.13 Models 800 & 800C (also includes HC & ADV Models) Commercial Rolling Steel Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +47/-47
 Other: Flat or insulated slat. 16' wide. Steel, concrete, and grout-filled CMU jambs.
Installation Instructions
 FL1421_R8_II_035-0005.pdf
 Verified By: John E. Scates, P.E. FL 51737
Test Reports
 FL1421_R8_TR_ATI_01-46387-01.pdf
1421.14 Models 800 & 800C (also includes HC & ADV Models) Commercial Rolling Steel Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +44/-44
 Other: Flat or insulated slat. 10' wide. Steel, concrete, and grout-filled CMU jambs.
Installation Instructions
 FL1421_R8_II_035-0001.pdf
 Verified By: John E. Scates, P.E. FL 51737
Test Reports
 FL1421_R8_TR_ATI 01-46389-01.pdf
1421.15 Models 800 & 800C (also includes HC & ADV Models) HVHZ Commercial Rolling Steel Door
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +47/-47
 Other: Flat or insulated slat. 10' wide. Steel and concrete jambs. HVHZ. (Reference NOA 18-0815.09)
Installation Instructions
 FL1421_R8_II_035-0031.pdf
 Verified By: John E. Scates, P.E. FL 51737
Test Reports
 FL1421_R8_TR_f7667 01-109-18-r0 - 800 Series NOA 10.pdf
1421.16 Models 800 & 800C (also includes HC & ADV Models) HVHZ Commercial Rolling Steel Door
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +55/-55
 Other: Flat or insulated slat. 22' wide. Steel and concrete jambs. HVHZ. (Reference NOA 18-0815.08)
Installation Instructions
 FL1421_R8_II_035-0036.pdf
 Verified By: John E. Scates, P.E. FL 51737
Test Reports
 FL1421_R8_TR_f7663 03-109-18-r0 - 800 Series NOA 22.pdf
1421.17 Models 800 & 800C (also includes HC & ADV Models) HVHZ Commercial Rolling Steel Door
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +47/-47
 Other: Flat or insulated slat. 16' wide. Steel and concrete jambs. HVHZ. (Reference NOA 18-0815.07)
Installation Instructions
 FL1421_R8_II_035-0032.pdf
 Verified By: John E. Scates, P.E. FL 51737
Test Reports
 FL1421_R8_TR_f7666 01-109-18-r0 - 800 Series NOA 16.pdf
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824