Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL41886-R10
Application Type Editorial Change
Code Version 2023
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer MI Windows and Doors
Address/Phone/Email 650 West Market Street
Gratz, PA 17030
(941) 480-1601
jrosowski@pgtindustries.com
 
Authorized Signature Brent Sitlinger
bsitlinger@miwd.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Windows
Subcategory Single Hung
 
Compliance Method Certification Mark or Listing
 
Certification Agency Fenestration and Glazing Industry Alliance (formerly AAMA)
Validated By Steven M. Urich, PE
  Validation Checklist - Hardcopy Received
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA/WDMA/CSA 101/I.S.2/A4402011
AAMA/WDMA/CSA 101/I.S.2/A4402017
 
Equivalence of Product Standards
Certified By

 
 
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 10/21/2025
Date Validated 10/21/2025
Date Pending FBC Approval
Date Approved 10/22/2025
 
Summary of Products
          Page 1 / 2    
FL # Model, Number or Name Description
41886.1 3540 SH 36x74 Fin Frame
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +35/-50
 Other: LC-PG35.
Certification Agency Certificate
 FL41886_R10_C_CAC_APC(11355)C7327.01-109-47-R1_3540 SH(041227) - 1.pdf
Quality Assurance Contract Expiration Date
 04/12/2027
Installation Instructions
 FL41886_R10_II_08-03347B.pdf
 Verified By: Luis R. Lomas, PE PE-62514
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41886_R10_AE_514337B.pdf
 Created by Independent Third Party: Yes
41886.2 3540 SH 40x66 Fin Frame
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +35/-47
 Other: R-PG35
Certification Agency Certificate
 FL41886_R10_C_CAC_APC(21882)28734.05-106-12-R0_3540 SH(050329).pdf
Quality Assurance Contract Expiration Date
 05/03/2029
Installation Instructions
 FL41886_R10_II_08-03349C.pdf
 Verified By: Luis R. Lomas, PE PE-62514
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41886_R10_AE_514339C.pdf
 Created by Independent Third Party: Yes
41886.3 3540 SH 44x63 Fin Frame
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +40/-47
 Other: R-PG40
Certification Agency Certificate
 FL41886_R10_C_CAC_MI Windows - 3540 SH (Fin) (5) Apr. 2025 (ext.5).pdf
Quality Assurance Contract Expiration Date
 05/26/2030
Installation Instructions
 FL41886_R10_II_08-03350B.pdf
 Verified By: Luis R. Lomas, PE PE-62514
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41886_R10_AE_514340B.pdf
 Created by Independent Third Party: Yes
41886.4 3540 SH 44x72 Fin Frame
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +35/-47
 Other: R-PG35
Certification Agency Certificate
 FL41886_R10_C_CAC_APC(11591)D0214.01-109-47-R0_3540 SH(080127) - 4.pdf
Quality Assurance Contract Expiration Date
 08/01/2027
Installation Instructions
 FL41886_R10_II_08-03351B.pdf
 Verified By: Luis R. Lomas, PE PE-62514
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41886_R10_AE_514341B.pdf
 Created by Independent Third Party: Yes
41886.5 3540 SH 44x84 Fin and Finless Frame
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +30/-30
 Other: R-PG30
Certification Agency Certificate
 FL41886_R10_C_CAC_APC(20272)11398.07-106-12-R1_3540 SH(041427).pdf
Quality Assurance Contract Expiration Date
 04/14/2027
Installation Instructions
 FL41886_R10_II_27488.08-1001 (Rev 1) - 3540 SH 44x84 Non-Impact Installations 2020 FBC R1.pdf
 Verified By: Michael D. Stremmel, PE PE-65868
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41886_R10_AE_27488.08-107-16-R0 - MI Windows and Doors 3540 SH 44x84.pdf
 Created by Independent Third Party: Yes
41886.6 3540 SH 52x84 Fin Frame
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +25/-25
 Other: R-PG25
Certification Agency Certificate
 FL41886_R10_C_CAC_MI Windows - 3540 SH (Fin Finless) (1) Apr. 2025 (ext.5).pdf
Quality Assurance Contract Expiration Date
 05/26/2030
Installation Instructions
 FL41886_R10_II_08-03354B.pdf
 Verified By: Luis R. Lomas, PE PE-62514
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41886_R10_AE_514344B.pdf
 Created by Independent Third Party: Yes
41886.7 3540 SH 36x74 Finless Frame
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +35/-50
 Other: LC-PG35
Certification Agency Certificate
 FL41886_R10_C_CAC_APC(11437)C7326.01-109-47-R0_3540 SH(082827) - 7.pdf
Quality Assurance Contract Expiration Date
 08/28/2027
Installation Instructions
 FL41886_R10_II_08-01252E1.pdf
 Verified By: Luis R. Lomas, PE PE-62514
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41886_R10_AE_511854E.pdf
 Created by Independent Third Party: Yes
41886.8 3540 SH 44x72 Finless Frame
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +35/-47
 Other: LC-PG35
Certification Agency Certificate
 FL41886_R10_C_CAC_APC(11439)C7326.01-109-47-R0_3540 SH(082827) - 8.pdf
Quality Assurance Contract Expiration Date
 08/28/2027
Installation Instructions
 FL41886_R10_II_08-01247E.pdf
 Verified By: Luis R. Lomas, PE PE-62514
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41886_R10_AE_511849E.pdf
 Created by Independent Third Party: Yes
41886.9 3540 SH 48x96 Finless Frame
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +30/-30
 Other: LC-PG30
Certification Agency Certificate
 FL41886_R10_C_CAC_APC(11438)C7326.01-109-47-R0_3540 SH(082827) - 9.pdf
Quality Assurance Contract Expiration Date
 08/28/2027
Installation Instructions
 FL41886_R10_II_08-03353C.pdf
 Verified By: Luis R. Lomas, PE PE-62514
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41886_R10_AE_514343C.pdf
 Created by Independent Third Party: Yes
41886.10 3540 SH 52x62 Finless Frame
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +35/-35
 Other: R-PG35
Certification Agency Certificate
 FL41886_R10_C_CAC_APC(11536)D0206.01-109-47-R0_3540 SH(082727) - 10.pdf
Quality Assurance Contract Expiration Date
 08/27/2027
Installation Instructions
 FL41886_R10_II_08-02269D.pdf
 Verified By: Luis R. Lomas, PE PE-62514
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41886_R10_AE_513015D.pdf
 Created by Independent Third Party: Yes
41886.11 3540 SH 52x72 Finless Frame
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +30/-30
 Other: R-PG30
Certification Agency Certificate
 FL41886_R10_C_CAC_APC(10818)C7325.01-109-47-R0_3540 SH(041227) - 11.pdf
Quality Assurance Contract Expiration Date
 04/12/2027
Installation Instructions
 FL41886_R10_II_08-02270D.pdf
 Verified By: Luis R. Lomas, PE PE-62514
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41886_R10_AE_513016D.pdf
 Created by Independent Third Party: Yes
41886.12 3540 SH 52x84 Finless Frame
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +25/-25
 Other: R-PG25
Certification Agency Certificate
 FL41886_R10_C_CAC_MI Windows - 3540 SH (Fin Finless) (1) Apr. 2025 (ext.5).pdf
Quality Assurance Contract Expiration Date
 05/26/2030
Installation Instructions
 FL41886_R10_II_08-01514D.pdf
 Verified By: Luis R. Lomas PE-62514
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41886_R10_AE_512141D.pdf
 Created by Independent Third Party: Yes
41886.13 3540 SH 48x72 Fin Frame
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +35/-35
 Other: R-PG35
Certification Agency Certificate
 FL41886_R10_C_CAC_APC(12775)A2726.01-109-47_3540 SH(072029).pdf
Quality Assurance Contract Expiration Date
 07/20/2029
Installation Instructions
 FL41886_R10_II_08-03352B.pdf
 Verified By: Luis R. Lomas PE-62514
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41886_R10_AE_514342B.pdf
 Created by Independent Third Party: Yes
41886.14 3540 SH 48x84 Fin and Finless Frame
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +30/-30
 Other: LC-PG30
Certification Agency Certificate
 FL41886_R10_C_CAC_APC(15761,15789)G0969.01-109-47,G0970.01-109-47_3540 SH(071926) - 14.pdf
Quality Assurance Contract Expiration Date
 07/19/2026
Installation Instructions
 FL41886_R10_II_08-03569B.pdf
 Verified By: Luis R. Lomas PE-62514
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41886_R10_AE_514651B.pdf
 Created by Independent Third Party: Yes
41886.15 3540 SH 48x85 Finless Frame
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +25/-25
 Other: LC-PG25
Certification Agency Certificate
 FL41886_R10_C_CAC_APC(11440)C7326.01-109-47-R0_3540 SH(082827) - 16.pdf
Quality Assurance Contract Expiration Date
 08/28/2027
Installation Instructions
 FL41886_R10_II_08-01246C.pdf
 Verified By: Luis R. Lomas PE-62514
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41886_R10_AE_511848C.pdf
 Created by Independent Third Party: Yes
41886.16 3540 SH 36x84 Finless Frame
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +50/-50
 Other: LC-PG40
Certification Agency Certificate
 FL41886_R10_C_CAC_APC(18108)1795.03-106-12-R3_3540 OR SH(030829).pdf
Quality Assurance Contract Expiration Date
 03/08/2029
Installation Instructions
 FL41886_R10_II_27488.06-1001 (Rev 2) - 3540 SH 36x84 Oriel Non-Impact Installations.pdf
 Verified By: Michael D. Stremmel, PE PE-65868
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41886_R10_AE_27488.06-107-16-R1 - MI Windows and Doors 3540 SH 36x84 Oriel.pdf
 Created by Independent Third Party: Yes
41886.17 3540 SH 52x62 Fin Frame
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +35/-35
 Other: R-PG35
Certification Agency Certificate
 FL41886_R10_C_CAC_APC(17188)1405.04-106-11-R0_3540 SH(120527) - 19.pdf
Quality Assurance Contract Expiration Date
 12/05/2027
Installation Instructions
 FL41886_R10_II_27488.01-1001 (Rev1) - 3540 SH Non-Impact Installations 2023 FBC.pdf
 Verified By: Michael D. Stremmel, PE PE-65868
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41886_R10_AE_27488.01-107-16 MI Windows and Doors 3540 SH 2023 FBC.pdf
 Created by Independent Third Party: Yes
41886.18 3540 SH 36x84 Fin Frame
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +35/-35
 Other: LC-PG35
Certification Agency Certificate
 FL41886_R10_C_CAC_APC(18225)G1596.01-109-47-R0_3540 SH 36X84(080526).pdf
Quality Assurance Contract Expiration Date
 08/05/2026
Installation Instructions
 FL41886_R10_II_29583.01-1001 - 3540 SH 36x84 Non-Impact Installations.pdf
 Verified By: Michael D Stremmel, PE PE-65868
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41886_R10_AE_29583.01-107-16-R0 (3540 SH 36x84).pdf
 Created by Independent Third Party: Yes
41886.19 3540 Triple SH 108x84 Fin Frame
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +35/-35
 Other: LC-PG35
Certification Agency Certificate
 FL41886_R10_C_CAC_APC(15747)G1596.01-109-47_3540 TPL SH(080526).pdf
Quality Assurance Contract Expiration Date
 08/05/2026
Installation Instructions
 FL41886_R10_II_30566.01-1001 - 3540 Triple Single Hung ‌Installation Drawings.pdf
 Verified By: Michael D Stremmel, PE PE-65868
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41886_R10_AE_30566.01-107-16-R0.pdf
 Created by Independent Third Party: Yes
41886.20 3540 Triple SH 120x84 Fin Frame
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +20/-20
 Other: R-PG20
Certification Agency Certificate
 FL41886_R10_C_CAC_APC(18082)1724.04-106-12-R0_3540 TPL SH(102428).pdf
Quality Assurance Contract Expiration Date
 10/24/2028
Installation Instructions
 FL41886_R10_II_08-03522A.pdf
 Verified By: Luis R. Lomas PE-62514
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41886_R10_AE_514576A.pdf
 Created by Independent Third Party: Yes
          Page 1 / 2    
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex