Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL48386
Application Type New
Code Version 2026
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Clopay Building Products Company
Address/Phone/Email 8585 Duke Blvd.
Mason, OH 45040
(513) 770-4641
jwheeler@clopay.com
 
Authorized Signature Ryan Thompson
RHThompson@clopay.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Exterior Doors
Subcategory Sectional Exterior Door Assemblies
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report James D. Wheeler
Florida License PE-91932
Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date 12/31/2030
Validated By Gary Pfuehler
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL48386_R0_COI_Certification_of_Independence_of_Validation_Entity-Gary_Pfuehler 2016-02-19.pdf
FL48386_R0_COI_Statement_of_Independence_of_Evaluation_Entity_JDW 260814.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ANSI/DASMA 1082005
ANSI/DASMA 1152005
ASTM E18862002
ASTM E19962002
ASTM E3302002
TAS 2011994
TAS 2031994
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL48386_R0_Equiv_Statement_on_Equivalency - E1886 - JDW 260814.pdf
FL48386_R0_Equiv_Statement_on_Equivalency - E330 - JDW 260814.pdf
 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 08/19/2026
Date Validated 09/04/2026
Date Pending FBC Approval 09/08/2026
Date Approved 10/13/2026
 
Summary of Products
          Page 1 / 3    
FL # Model, Number or Name Description
48386.1 001 W3-09 DSIE-1A171: 2050, 4050, 2051, 4051, 2053, 4053, 62, 62G, 62LG, 6130, 65, 65G, 6131, 64, 64G, 6133, 135, SDP38, 136, SFL38, 134, SRP38 Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 29 ga. min.) Single-Car (up to 9’0” wide) WINDCODE® W3 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +20/-21
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing (solid door) DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL48386_R0_II_101655-Rev15.pdf
 FL48386_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48386_R0_AE_CCER_260818-A-00.pdf
 Created by Independent Third Party: No
48386.2 002 W3-16 DSIE-1A171: 2050, 2051, 2053, 4050, 4051, 4053, 62, 64, 65, 62G, 62LG, 64G, SDP38, SFL38, SRP38, 134, 135, 136, 6130, 6131, 6133 Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 29 ga. min.) Single-Car (up to 9’0” wide) WINDCODE® W3 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +20/-21
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing (solid door) DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL48386_R0_II_101820-Rev16.pdf
 FL48386_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48386_R0_AE_CCER_260818-A-00.pdf
 Created by Independent Third Party: No
48386.3 003 W5-16 DSIE-1A171: 2050, 2051, 2053, 4050, 4051, 4053, 62, 64, 65, 62G, 62LG, 64G, SDP38, SFL38, SRP38, 134, 135, 136, 6130, 6131, 6133 Double-skin Insulated EPS (exterior skin 24 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, up to 14'2” wide
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +30/-30
 Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions.
Installation Instructions
 FL48386_R0_II_101595-B-Rev15.pdf
 FL48386_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48386_R0_AE_CCER_260818-A-00.pdf
 Created by Independent Third Party: No
48386.4 004 W5-16 DSIE-1A171: 2050, 2051, 2053, 4050, 4051, 4053, 62, 64, 65, 62G, 62LG, 64G, SDP38, SFL38, SRP38, 134, 135, 136, 6130, 6131, 6133 1-3/8" Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 29 ga. min.) Double-Car (9’2” to 16’0” wide) WINDCODE® W5 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +30/-30
 Other: Solid doors (no glazing) are impact-resistant (large missile impact).
Installation Instructions
 FL48386_R0_II_101595-A-Rev15.pdf
 FL48386_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48386_R0_AE_CCER_260818-A-00.pdf
 Created by Independent Third Party: No
48386.5 005 W5-16-HY DSIE-1A171: 2050, 2051, 2053, 4050, 4051, 4053, 62, 64, 65, 62G, 62LG, 64G, SDP38, SFL38, SRP38, 134, 135, 136, 6130, 6131, 6133 1-3/8" Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 29 ga. min.) Double-Car (9’2” to 16’0” wide) WINDCODE® W5 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +32/-32
 Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions.
Installation Instructions
 FL48386_R0_II_102185-B-Rev14.pdf
 FL48386_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48386_R0_AE_CCER_260818-A-00.pdf
 Created by Independent Third Party: No
48386.6 006 W5-16-HY DSIE-1A171: 2050, 2051, 2053, 4050, 4051, 4053, 62, 64, 65, 62G, 62LG, 64G, SDP38, SFL38, SRP38, 134, 135, 136, 6130, 6131, 6133 1-3/8" Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 29 ga. min.) Double-Car (9’2” to 16’0” wide) WINDCODE® W5 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +32/-32
 Other: Solid doors (no glazing) are impact-resistant (large missile impact).
Installation Instructions
 FL48386_R0_II_102185-A-Rev14.pdf
 FL48386_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48386_R0_AE_CCER_260818-A-00.pdf
 Created by Independent Third Party: No
48386.7 007 W6-09 DSIE-1A171: 2050, 2051, 2053, 4050, 4051, 4053, 62, 64, 65, 62G, 62LG, 64G, SDP38, SFL38, SRP38, 134, 135, 136, 6130, 6131, 6133 1-3/8" Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 29 ga. min.) Single-Car (up to 9’0” wide) WINDCODE® W6 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +36/-37
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing (solid door) DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL48386_R0_II_101654-A-Rev18.pdf
 FL48386_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48386_R0_AE_CCER_260818-A-00.pdf
 Created by Independent Third Party: No
48386.8 008 W6-09 DSIE-1A171: 2050, 2051, 2053, 4050, 4051, 4053, 62, 64, 65, 62G, 62LG, 64G, SDP38, SFL38, SRP38, 134, 135, 136, 6130, 6131, 6133 Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 29 ga. min.) Single-Car (up to 9’0” wide) WINDCODE® W6 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +36/-44
 Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions.
Installation Instructions
 FL48386_R0_II_104814-B-Rev01.pdf
 FL48386_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48386_R0_AE_CCER_260818-A-00.pdf
 Created by Independent Third Party: No
48386.9 009 W6-09 DSIE-1A171: 2050, 2051, 2053, 4050, 4051, 4053, 62, 64, 65, 62G, 62LG, 64G, SDP38, SFL38, SRP38, 134, 135, 136, 6130, 6131, 6133 Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 29 ga. min.) Single-Car (up to 9’0” wide) WINDCODE® W6 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +36/-44
 Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors (no glazing) are impact-resistant (large missile impact).
Installation Instructions
 FL48386_R0_II_104814-A-Rev01.pdf
 FL48386_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48386_R0_AE_CCER_260818-A-00.pdf
 Created by Independent Third Party: No
48386.10 010 W4-09 DSIE-1F171: 4300, 4301, 4310, 4400, 4401, HDG, HDGL, HDGF, 66, 66G, 67, 67G, 68, SP200, SF200, SE200, 6200, 6201, 6203 2" Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9'0" wide) WINDCODE® W4 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +28/-29
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing (solid door) DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL48386_R0_II_101652-B-Rev12.pdf
 FL48386_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48386_R0_AE_CCER_260818-A-00.pdf
 Created by Independent Third Party: No
48386.11 011 W4-09 DSIE-1F171: 4300, 4301, 4310, 4400, 4401, HDG, HDGL, HDGF, 66, 66G, 67, 67G, 68, SP200, SF200, SE200, 6200, 6201, 6203 2" Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9'0" wide) WINDCODE® W4 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +28/-29
 Other: Solid doors (no glazing) or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
Installation Instructions
 FL48386_R0_II_101652-A-Rev12.pdf
 FL48386_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48386_R0_AE_CCER_260818-A-00.pdf
 Created by Independent Third Party: No
48386.12 012 W4-16 DSIE-1F171: 4300, 4301, 4310, 4400, 4401, HDG, HDGL, HDGF, 66, 66G, 67, 67G, 68, SP200, SF200, SE200, 6200, 6201, 6203 2" Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (9'2" to 16'0" wide) WINDCODE® W4 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +25.5/-25.5
 Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions.
Installation Instructions
 FL48386_R0_II_101481-B-Rev15.pdf
 FL48386_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48386_R0_AE_CCER_260818-A-00.pdf
 Created by Independent Third Party: No
48386.13 013 W4-16 DSIE-1F171: 4300, 4301, 4310, 4400, 4401, HDG, HDGL, HDGF, 66, 66G, 67, 67G, 68, SP200, SF200, SE200, 6200, 6201, 6203 2" Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (9'2" to 16'0" wide) WINDCODE® W4 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +25/-25
 Other: Solid doors (no glazing) or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
Installation Instructions
 FL48386_R0_II_101481-A-Rev15.pdf
 FL48386_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48386_R0_AE_CCER_260818-A-00.pdf
 Created by Independent Third Party: No
48386.14 014 W4-18 DSIE-1F171: 4300, 4301, 4310, 4400, 4401, HDG, HDGL, HDGF, 66, 66G, 67, 67G, 68, SP200, SF200, SE200, 6200, 6201, 6203 2" Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) 16'2" to 18'0" wide WINDCODE® W4 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +25/-25
 Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions.
Installation Instructions
 FL48386_R0_II_101247-B-Rev21.pdf
 FL48386_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48386_R0_AE_CCER_260818-A-00.pdf
 Created by Independent Third Party: No
48386.15 015 W4-18 DSIE-1F171: 4300, 4301, 4310, 4400, 4401, HDG, HDGL, HDGF, 66, 66G, 67, 67G, 68, SP200, SF200, SE200, 6200, 6201, 6203 2" Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) 16'2" to 18'0" wide WINDCODE® W4 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +25/-25
 Other: Solid doors (no glazing) or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
Installation Instructions
 FL48386_R0_II_101247-A-Rev21.pdf
 FL48386_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48386_R0_AE_CCER_260818-A-00.pdf
 Created by Independent Third Party: No
48386.16 016 W5-20 DSIE-1F171: 4300, 4301, 4310, HDG, HDGL, HDGF, 66, 66G, 67, 67G, 68, SP200, SF200, SE200, 6200, 6201, 6203 Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (up to 20'2" wide) WINDCODE® W5 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +32/-37
 Other: Doors with standard glazing meet the wind load requirements of the building code but DO NOT meet the impact resistant requirement for windborne debris regions.
Installation Instructions
 FL48386_R0_II_104945-Rev03.pdf
 FL48386_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48386_R0_AE_CCER_260818-A-00.pdf
 Created by Independent Third Party: No
48386.17 017 W6-09 DSIE-1F171: 4400, 4401, 4300, 4301, 4310, HDG, HDGL, HDGF, 66, 66G, 67, 67G, 68, SP200, SF200, SE200, 6200, 6201, 6203 Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9'0" wide) WINDCODE® W6 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +38/-44
 Other: Doors with standard glazing meet the wind load requirements of the building code but DO NOT meet the impact resistant requirement for windborne debris regions.
Installation Instructions
 FL48386_R0_II_101526-B-Rev22.pdf
 FL48386_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48386_R0_AE_CCER_260818-A-00.pdf
 Created by Independent Third Party: No
48386.18 018 W6-09 DSIE-1F171: 4400, 4401, 4300, 4301, 4310, HDG, HDGL, HDGF, 66, 66G, 67, 67G, 68, SP200, SF200, SE200, 6200, 6201, 6203 Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9'0" wide) WINDCODE® W6 Garage Door with Optional Impact-Resistant Lites
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +38/-44
 Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors (no glazing) or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
Installation Instructions
 FL48386_R0_II_101526-A-Rev22.pdf
 FL48386_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48386_R0_AE_CCER_260818-A-00.pdf
 Created by Independent Third Party: No
48386.19 019 W6-16 DSIE-1F171: 4300, 4301, 4310, HDG, HDGL, HDGF, 66, 66G, 67, 67G, 68, SP200, SF200, SE200, 6200, 6201, 6203 Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (9'2" to 16'2" wide) WINDCODE® W6 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +38/-42
 Other: Doors with standard glazing meet the wind load requirements of the building code but DO NOT meet the impact resistant requirement for windborne debris regions.
Installation Instructions
 FL48386_R0_II_104724-B-Rev06.pdf
 FL48386_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48386_R0_AE_CCER_260818-A-00.pdf
 Created by Independent Third Party: No
48386.20 020 W6-16 DSIE-1F171: 4300, 4301, 4310, HDG, HDGL, HDGF, 66, 66G, 67, 67G, 68, SP200, SF200, SE200, 6200, 6201, 6203 Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (9'2" to 16'2" wide) WINDCODE® W6 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +38/-42
 Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors (no glazing) or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
Installation Instructions
 FL48386_R0_II_104724-A-Rev06.pdf
 FL48386_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48386_R0_AE_CCER_260818-A-00.pdf
 Created by Independent Third Party: No
          Page 1 / 3    
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts: