| 16848.1 |
001 W6-10 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224S, C4ST, C4SV, C4SS, C0ST, C0SS |
Ribbed Steel (min. 24 ga.) WINDCODE® W6 Sectional Door, up to 10’2” wide (Solid, no glazing)
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +37 PSF/-42 PSF Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors are impact-resistant (large missile impact).
|
Installation Instructions FL16848_R8_II_102445-A-Rev10.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL16848_R8_AE_CBPC_140220-B.pdf Created by Independent Third Party: No |
|
|
| 16848.2 |
002 W6-10 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224S, C4ST, C4SV, C4SS, C0ST, C0SS |
Ribbed Steel (min. 24 ga.) WINDCODE® W6 Sectional Door, up to 10’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +37 PSF/-44 PSF Other: Doors with standard glazing meet the wind load requirements of the building code but DO NOT meet the impact resistant requirement for windborne debris regions.
|
Installation Instructions FL16848_R8_II_102445-B-Rev10.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL16848_R8_AE_CBPC_140220-B.pdf Created by Independent Third Party: No |
|
|
| 16848.3 |
003 W6-16 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224S, C4ST, C4SV, C4SS, C0ST, C0SS |
Ribbed Steel (min. 24 ga.) WINDCODE® W6 Sectional Door, up to 16’2” wide (Solid, no glazing)
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +38 PSF/-42 PSF Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
|
Installation Instructions FL16848_R8_II_104858-Rev02.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL16848_R8_AE_CBPC_140220-B.pdf Created by Independent Third Party: No |
|
|
| 16848.4 |
004 W8-12 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224S, C4ST, C4SV, C4SS, C0ST, C0SS |
Ribbed Steel (min. 24 ga.) WINDCODE® W8 Sectional Door, up to 12’2” wide (Solid, no glazing)
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +52 PSF/-58 PSF Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors are impact-resistant (large missile impact).
|
Installation Instructions FL16848_R8_II_104813-Rev01.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL16848_R8_AE_CBPC_140220-B.pdf Created by Independent Third Party: No |
|
|
| 16848.5 |
005 W6-10 C-DSIU-1D477: 3717, C7X17, 3718, C7X18, 3720, C7X20, 240U, 3722, C0X22, 3724, C7X24, 244U, 3730 |
Double-skin Insulated (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W6 Sectional Door, up to 10’2” wide with Optional Impact-Resistant Lites
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +37 PSF/-44 PSF Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
|
Installation Instructions FL16848_R8_II_104039-A-Rev08.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL16848_R8_AE_CBPC_140220-B-04.pdf Created by Independent Third Party: No |
|
|
| 16848.6 |
006 W6-10 C-DSIU-1D477: 3717, C7X17, 3718, C7X18, 3720, C7X20, 240U, 3722, C0X22, 3724, C7X24, 244U, 3730 |
Double-skin Insulated (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W6 Sectional Door, up to 10’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +37 PSF/-44 PSF Other: Doors with standard glazing meet the wind load requirements of the building code but DO NOT meet the impact resistant requirement for windborne debris regions.
|
Installation Instructions FL16848_R8_II_104039-B-Rev07.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL16848_R8_AE_CBPC_140220-B.3.pdf Created by Independent Third Party: No |
|
|
| 16848.7 |
007 W6-14 C-DSIU-1D477: 3717, C7X17, 3718, C7X18, 3720, C7X20, 240U, 3722, C0X22, 3724, C7X24, 244U, 3730 |
Double-skin Insulated (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W6 Sectional Door, up to 14’2” wide with Optional Impact-Resistant Lites
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +36 PSF/-40 PSF Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
|
Installation Instructions FL16848_R8_II_104861-A-Rev03.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL16848_R8_AE_CBPC_140220-B-04.pdf Created by Independent Third Party: No |
|
|
| 16848.8 |
008 W6-14 C-DSIU-1D477: 3717, C7X17, 3718, C7X18, 3720, C7X20, 240U, 3722, C0X22, 3724, C7X24, 244U, 3730 |
Double-skin Insulated (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W6 Sectional Door, up to 14’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +36 PSF/-40 PSF Other: Doors with standard glazing meet the wind load requirements of the building code but DO NOT meet the impact resistant requirement for windborne debris regions.
|
Installation Instructions FL16848_R8_II_104861-B-Rev02.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL16848_R8_AE_CBPC_140220-B.3.pdf Created by Independent Third Party: No |
|
|
| 16848.9 |
009 W6-16 C-DSIU-1D477: 3717, C7X17, 3718, C7X18, 3720, C7X20, 240U, 3722, C0X22, 3724, C7X24, 244U, 3730 |
Double-skin Insulated (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W6 Sectional Door, up to 16’2” wide with Optional Impact-Resistant Lites
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +37 PSF/-42 PSF Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
|
Installation Instructions FL16848_R8_II_104801-A-Rev05.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL16848_R8_AE_CBPC_140220-B-04.pdf Created by Independent Third Party: No |
|
|
| 16848.10 |
010 W6-16 C-DSIU-1D477: 3717, C7X17, 3718, C7X18, 3720, C7X20, 240U, 3722, C0X22, 3724, C7X24, 244U, 3730 |
Double-skin Insulated (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W6 Sectional Door, up to 16’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +37 PSF/-42 PSF Other: Doors with standard glazing meet the wind load requirements of the building code but DO NOT meet the impact resistant requirement for windborne debris regions.
|
Installation Instructions FL16848_R8_II_104801-B-Rev04.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL16848_R8_AE_CBPC_140220-B.3.pdf Created by Independent Third Party: No |
|
|
| 16848.11 |
011 W6-18 C-DSIU-1D477: 3717, C7X17, 3718, C7X18, 3720, C7X20, 240U, 3722, C0X22, 3724, C7X24, 244U, 3730 |
Double-skin Insulated (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W6 Sectional Door, up to 18’2” wide with Optional Impact-Resistant Lites
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +36 PSF/-40 PSF Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
|
Installation Instructions FL16848_R8_II_104826-A-Rev04.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL16848_R8_AE_CBPC_140220-B-04.pdf Created by Independent Third Party: No |
|
|
| 16848.12 |
012 W6-18 C-DSIU-1D477: 3717, C7X17, 3718, C7X18, 3720, C7X20, 240U, 3722, C0X22, 3724, C7X24, 244U, 3730 |
Double-skin Insulated (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W6 Sectional Door, up to 18’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +36 PSF/-40 PSF Other: Doors with standard glazing meet the wind load requirements of the building code but DO NOT meet the impact resistant requirement for windborne debris regions.
|
Installation Instructions FL16848_R8_II_104826-B-Rev03.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL16848_R8_AE_CBPC_140220-B.3.pdf Created by Independent Third Party: No |