FL # FL48404
Application Type New
Code Version 2026
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Clopay Building Products Company
Address/Phone/Email 8585 Duke Blvd.
Mason, OH 45040
(513) 770-4641
jwheeler@clopay.com
 
Authorized Signature Jim Wheeler
jwheeler@clopay.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Exterior Doors
Subcategory Sectional Exterior Door Assemblies
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report James D. Wheeler
Florida License PE-91932
Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date 12/31/2030
Validated By Gary Pfuehler
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL48404_R0_COI_Certification_of_Independence_of_Validation_Entity-Gary_Pfuehler 2016-02-19.pdf
FL48404_R0_COI_Statement_of_Independence_of_Evaluation_Entity_JDW 260814.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ANSI/DASMA 1082005
ANSI/DASMA 1152005
ASTM E18862002
ASTM E19962002
ASTM E3302002
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL48404_R0_Equiv_Statement_on_Equivalency - E1886 - JDW 260814.pdf
FL48404_R0_Equiv_Statement_on_Equivalency - E330 - JDW 260814.pdf
 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 08/20/2026
Date Validated 09/04/2026
Date Pending FBC Approval 09/08/2026
Date Approved 10/13/2026
 
Summary of Products
          Page 1 / 2    
FL # Model, Number or Name Description
48404.1 001 W2-09 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224V, 224S, C4ST, C4SV, C4SS, C0ST, C0SS Ribbed Steel (min. 24 ga.) WINDCODE® W2 Sectional Door, up to 9’2” wide
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +18/-20
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL48404_R0_II_105410-Rev04.pdf
 FL48404_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48404_R0_AE_CCER_260801-A-00.pdf
 Created by Independent Third Party: No
48404.2 002 W4-09 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224V, 224S, C4ST, C4SV, C4SS, C0ST, C0SS Ribbed Steel (min. 24 ga.) WINDCODE® W4 Sectional Door, up to 9’2” wide
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +25/-25
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL48404_R0_II_105412-Rev01.pdf
 FL48404_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48404_R0_AE_CCER_260801-A-00.pdf
 Created by Independent Third Party: No
48404.3 003 W4-16 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224V, 224S, C4ST, C4SV, C4SS, C0ST, C0SS Ribbed Steel (min. 24 ga.) WINDCODE® W4 Sectional Door, up to 16’2” wide
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +25/-25
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL48404_R0_II_105032-Rev01.pdf
 FL48404_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48404_R0_AE_CCER_260801-A-00.pdf
 Created by Independent Third Party: No
48404.4 004 W4-20 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224V, 224S, C4ST, C4SV, C4SS, C0ST, C0SS Ribbed Steel (min. 24 ga.) WINDCODE® W4 Sectional Door, up to 20’2” wide
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +25/-25
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL48404_R0_II_105077-Rev02.pdf
 FL48404_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48404_R0_AE_CCER_260801-A-00.pdf
 Created by Independent Third Party: No
48404.5 005 W4-24 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224V, 224S, C4ST, C4SV, C4SS, C0ST, C0SS Ribbed Steel (min. 24 ga.) WINDCODE® W4 Sectional Door, up to 24’2” wide
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +25/-25
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL48404_R0_II_105196-Rev02.pdf
 FL48404_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48404_R0_AE_CCER_260801-A-00.pdf
 Created by Independent Third Party: No
48404.6 006 W5-08 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224S, C4ST C4SV, C4SS, C0ST, C0SS Ribbed Steel (min. 24 ga.) WINDCODE® W5 Sectional Door, up to 8’2” wide
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +30/-30
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL48404_R0_II_101874-Rev13.pdf
 FL48404_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48404_R0_AE_CCER_260801-A-00.pdf
 Created by Independent Third Party: No
48404.7 007 W5-10 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224S, C4ST C4SV, C4SS, C0ST, C0SS Ribbed Steel (min. 24 ga.) WINDCODE® W5 Sectional Door, 8’4” to 10’2” wide
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +30/-30
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL48404_R0_II_101875-Rev12.pdf
 FL48404_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48404_R0_AE_CCER_260801-A-00.pdf
 Created by Independent Third Party: No
48404.8 008 W5-12 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224S, C4ST C4SV, C4SS, C0ST, C0SS Ribbed Steel (min. 24 ga.) WINDCODE® W5 Sectional Door, 10’4” to 12’2” wide
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +30/-30
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL48404_R0_II_101869-Rev13.pdf
 FL48404_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48404_R0_AE_CCER_260801-A-00.pdf
 Created by Independent Third Party: No
48404.9 009 W5-16 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224V, 224S, C4ST, C4SV, C4SS, C0ST, C0SS Ribbed Steel (min. 24 ga.) WINDCODE® W5 Sectional Door, up to 16’2” wide
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +32/-32
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL48404_R0_II_105033-Rev02.pdf
 FL48404_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48404_R0_AE_CCER_260801-A-00.pdf
 Created by Independent Third Party: No
48404.10 010 W5-22 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224V, 224S, C4ST, C4SV, C4SS, C0ST, C0SS Ribbed Steel (min. 24 ga.) WINDCODE® W5 Sectional Door, up to 22’2” wide
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +30/-30
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL48404_R0_II_105064-Rev02.pdf
 FL48404_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48404_R0_AE_CCER_260801-A-00.pdf
 Created by Independent Third Party: No
48404.11 011 W6-10 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224S, C4ST, C4SV, C4SS, C0ST, C0SS Ribbed Steel (min. 24 ga.) WINDCODE® W6 Sectional Door, up to 10’2” wide
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +37/-44
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL48404_R0_II_102445-B-Rev10.pdf
 FL48404_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48404_R0_AE_CCER_260801-A-00.pdf
 Created by Independent Third Party: No
48404.12 012 W6-12 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224S, C4ST C4SV, C4SS, C0ST, C0SS Ribbed Steel (min. 24 ga.) WINDCODE® W6 Sectional Door, 10’4” to 12’2” wide
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +37/-42
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL48404_R0_II_102446-Rev10pdf.pdf
 FL48404_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48404_R0_AE_CCER_260801-A-00.pdf
 Created by Independent Third Party: No
48404.13 013 W4-12 C-PAN-1E458: 525, 525V, 525S, 524, 524V, 524S, 520, 520S, 225, 225S, 224, 224S, C5EST, C5ST, C5ESV, C5SV, C5ESS, C5SS, C4ST C4SV, C4SS, C0ST, C0SS Ribbed Steel (min. 25 ga.) WINDCODE® W4 Sectional Door, up to 12’2” wide
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +25/-25
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL48404_R0_II_101856-Rev13.pdf
 FL48404_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48404_R0_AE_CCER_260801-A-00.pdf
 Created by Independent Third Party: No
48404.14 014 W5-09 C-PAN-1E458: 525, 525V, 525S, 225, 225S,C5EST, C5ST, C5ESV, C5SV, C5ESS, C5SS Ribbed Steel (min. 25 ga.) WINDCODE® W5 Sectional Door, up to 9’2” wide
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +30/-30
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL48404_R0_II_105676-Rev00.pdf
 FL48404_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48404_R0_AE_CCER_260801-A-00.pdf
 Created by Independent Third Party: No
48404.15 015 W4-09 C-PAN-2F141: 692, 652V Steel Pan (min. 24 ga.) WINDCODE® W4 Sectional Door, up to 9’0” wide
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +25/-32
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL48404_R0_II_101762-Rev10.pdf
 FL48404_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48404_R0_AE_CCER_260801-A-00.pdf
 Created by Independent Third Party: No
48404.16 016 W4-16 C-PAN-2F141: 692, 652V Steel Pan (min. 24 ga.) WINDCODE® W4 Sectional Door, 9’2” to 16’0” wide
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +24/-24.5
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL48404_R0_II_101781-Rev09.pdf
 FL48404_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48404_R0_AE_CCER_260801-A-00.pdf
 Created by Independent Third Party: No
48404.17 017 W6-10 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224S, C4ST, C4SV, C4SS, C0ST, C0SS Ribbed Steel (min. 24 ga.) WINDCODE® W6 Sectional Door, up to 10’2” wide (Solid, no glazing)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +37/-42
 Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors are impact-resistant (large missile impact).
Installation Instructions
 FL48404_R0_II_102445-A-Rev10.pdf
 FL48404_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48404_R0_AE_CCER_260801-A-00.pdf
 Created by Independent Third Party: No
48404.18 018 W6-12 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224V, 224S, C4ST, C4SV, C4SS, C0ST, C0SS Ribbed Steel (min. 24 ga.) WINDCODE® W6 Sectional Door, up to 12’2” wide (Solid, no glazing)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +36/-42
 Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors are impact-resistant (large missile impact).
Installation Instructions
 FL48404_R0_II_104811-Rev03.pdf
 FL48404_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48404_R0_AE_CCER_260801-A-00.pdf
 Created by Independent Third Party: No
48404.19 019 W6-14 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224V, 224S, C4ST, C4SV, C4SS, C0ST, C0SS Ribbed Steel (min. 24 ga.) WINDCODE® W6 Sectional Door, up to 14’2” wide (Solid, no glazing)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +38/-42
 Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors are impact-resistant (large missile impact).
Installation Instructions
 FL48404_R0_II_104924-Rev03.pdf
 FL48404_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48404_R0_AE_CCER_260801-A-00.pdf
 Created by Independent Third Party: No
48404.20 020 W6-16 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224S, C4ST, C4SV, C4SS, C0ST, C0SS Ribbed Steel (min. 24 ga.) WINDCODE® W6 Sectional Door, up to 16’2” wide (Solid, no glazing)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +38/-42
 Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors are impact-resistant (large missile impact).
Installation Instructions
 FL48404_R0_II_104858-Rev02.pdf
 FL48404_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL48404_R0_AE_CCER_260801-A-00.pdf
 Created by Independent Third Party: No
          Page 1 / 2    
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex