| 47958.1 |
001 W4-09 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 |
Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9’0” wide) WINDCODE® W4 Garage Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25 PSF/-28 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC). |
Installation Instructions FL47958_R1_II_104947-Rev02.pdf FL47958_R1_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL47958_R1_AE_CCER_251214-B-00.pdf Created by Independent Third Party: No |
|
|
| 47958.2 |
002 W4-16 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 |
Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (9’2” to 16’0” wide) WINDCODE® W4 Garage Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +24 PSF/-26.5 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC). |
Installation Instructions FL47958_R1_II_104704-Rev02.pdf FL47958_R1_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL47958_R1_AE_CCER_251214-B-00.pdf Created by Independent Third Party: No |
|
|
| 47958.3 |
003 W4-18 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 |
Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) 16'2" to 18'0" wide WINDCODE® W4 Garage Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +24 PSF/-26 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC). |
Installation Instructions FL47958_R1_II_104887-Rev02.pdf FL47958_R1_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL47958_R1_AE_CCER_251214-B-00.pdf Created by Independent Third Party: No |
|
|
| 47958.4 |
004 W5-09 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9’0” wide) WINDCODE® W5 Garage Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +33 PSF/-37 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. |
Installation Instructions FL47958_R1_II_104866-Rev04.pdf FL47958_R1_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL47958_R1_AE_CCER_251214-B-00.pdf Created by Independent Third Party: No |
|
|
| 47958.5 |
005 W5-16 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 |
Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (9’2” to 16’0” wide) WINDCODE® W5 Garage Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +32 PSF/-32 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC). |
Installation Instructions FL47958_R1_II_104191-Rev04.pdf FL47958_R1_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL47958_R1_AE_CCER_251214-B-00.pdf Created by Independent Third Party: No |
|
|
| 47958.6 |
006 W3-09 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 |
Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9’0” wide) WINDCODE® W3 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +20/-21 Other: : The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC). |
Installation Instructions FL47958_R1_II_104175-Rev04.pdf FL47958_R1_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL47958_R1_AE_CCER_260814-A-00.pdf Created by Independent Third Party: No |
|
|
| 47958.7 |
007 W3-16 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 |
Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (9’2” to 16’0” wide) WINDCODE® W3 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +20/-21 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL47958_R1_II_104947-Rev02.pdf FL47958_R1_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL47958_R1_AE_CCER_260814-A-00.pdf Created by Independent Third Party: No |
|
|
| 47958.8 |
008 W5-09 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9’0” wide) WINDCODE® W5 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +33/-37 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL47958_R1_II_104866-B-Rev04.pdf FL47958_R1_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL47958_R1_AE_CCER_260814-A-00.pdf Created by Independent Third Party: No |
|
|
| 47958.9 |
009 W6-09 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 |
Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9’0” wide) WINDCODE® W6 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +37/-37 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL47958_R1_II_104180-Rev02.pdf FL47958_R1_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL47958_R1_AE_CCER_260814-A-00.pdf Created by Independent Third Party: No |
|
|
| 47958.10 |
010 W3-09 DSIU-1A471: GD1SU, GR1SU, GD1LU, GR1LU, AR1SU, AR1LU, ED1SU, ED1LU, 9132, HDPC13, 7132, 8135, MFC38U |
Gallery/Artistry/Expressions: 1-3/8" Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9’0” wide) WINDCODE® W3 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +20/-21 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL47958_R1_II_104424-Rev02.pdf FL47958_R1_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL47958_R1_AE_CCER_260814-A-00.pdf Created by Independent Third Party: No |
|
|
| 47958.11 |
011 W3-16 DSIU-1A471: GD1SU, GR1SU, GD1LU, GR1LU, AR1SU, AR1LU, ED1SU, ED1LU |
Double-skin Insulated Intellicore (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (9'2" to 16'0" wide) WINDCODE® W3 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +20/-21 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL47958_R1_II_104425-Rev02.pdf FL47958_R1_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL47958_R1_AE_CCER_260814-A-00.pdf Created by Independent Third Party: No |
|
|
| 47958.12 |
012 W5-09 DSIU-1A471: GD1SU, GR1SU, GD1LU, GR1LU, AR1SU, AR1LU, ED1SU, ED1LU, 9132, HDPC13, 7132, 8135, MFC38U |
Gallery/Artistry/Expressions: 1-3/8" Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9’0” wide) WINDCODE® W5 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +30/-32 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL47958_R1_II_104426-Rev01.pdf FL47958_R1_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL47958_R1_AE_CCER_260814-A-00.pdf Created by Independent Third Party: No |
|
|
| 47958.13 |
013 W5-16 DSIU-1A471: GD1SU, GR1SU, GD1LU, GR1LU, AR1SU, AR1LU, ED1SU, ED1LU |
Double-skin Insulated Intellicore (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (9'2" to 16'0" wide) WINDCODE® W5 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +30/-30 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL47958_R1_II_104427-Rev02.pdf FL47958_R1_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL47958_R1_AE_CCER_260814-A-00.pdf Created by Independent Third Party: No |
|
|
| 47958.14 |
014 W4-09 DSIU-1F171: 9200, 9201, 9203, HDP20, HDPF20, HDPL20, 7200, 7201, 7203, 8200, 8201, 8203 |
Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9'0" wide) WINDCODE® W4 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +28/-29 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL47958_R1_II_104183-Rev04.pdf FL47958_R1_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL47958_R1_AE_CCER_260814-A-00.pdf Created by Independent Third Party: No |
|
|
| 47958.15 |
015 W4-16 DSIU-1F171: 9200, 9201, 9203, HDP20, HDPF20, HDPL20, 7200, 7201, 7203, 8200, 8201, 8203 |
Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (9'2" to 16'0" wide) WINDCODE® W4 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25.5/-25.5 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL47958_R1_II_104169-Rev04.pdf FL47958_R1_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL47958_R1_AE_CCER_260814-A-00.pdf Created by Independent Third Party: No |
|
|
| 47958.16 |
016 W4-18 DSIU-1F171: 9200, 9201, 9203, HDP20, HDPF20, HDPL20, 7200, 7201, 7203, 8200, 8201, 8203 |
Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) 16'2" to 18'0" wide WINDCODE® W4 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25/-25 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL47958_R1_II_104260-Rev04.pdf FL47958_R1_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL47958_R1_AE_CCER_260814-A-00.pdf Created by Independent Third Party: No |
|
|
| 47958.17 |
017 W5-09 DSIU-1F171: 9200, 9201, 9203, HDP20, HDPF20, HDPL20, 7200, 7201, 7203, 8200, 8201, 8203 |
Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9'0" wide) WINDCODE® W5 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-32 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL47958_R1_II_104188-Rev03.pdf FL47958_R1_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL47958_R1_AE_CCER_260814-A-00.pdf Created by Independent Third Party: No |
|
|
| 47958.18 |
018 W6-09 DSIU-1F171: 9200, 9201, 9203, HDP20, HDPF20, HDPL20, 7200, 7201, 7203, 8200, 8201, 8203 |
Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9'0" wide) WINDCODE® W6 Garage Door with Optional Impact-Resistant Lites
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +38/-44 Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
|
Installation Instructions FL47958_R1_II_104184-A-Rev05.pdf FL47958_R1_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL47958_R1_AE_CCER_260814-A-00.pdf Created by Independent Third Party: No |
|
|
| 47958.19 |
019 W6-09 DSIU-1F171: 9200, 9201, 9203, HDP20, HDPF20, HDPL20, 7200, 7201, 7203, 8200, 8201, 8203 |
Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9'0" wide) WINDCODE® W6 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +38/-44 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL47958_R1_II_104184-B-Rev05.pdf FL47958_R1_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL47958_R1_AE_CCER_260814-A-00.pdf Created by Independent Third Party: No |
|
|
| 47958.20 |
020 W6-16 DSIU-1F171: 9200, 9201, 9203, HDP20, HDPF20, HDPL20, 7200, 7201, 7203, 8200, 8201, 8203 |
Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (9'2" to 16'2" wide) WINDCODE® W6 Garage Door with Optional Impact-Resistant Lites
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +37/-41 Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
|
Installation Instructions FL47958_R1_II_104234-A-Rev02.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL47958_R1_AE_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf FL47958_R1_AE_CCER_260814-A-00.pdf Created by Independent Third Party: No |