| 5678.1 | 
01 W4-09 C-DSIE-1F173: 3201, 3203, 250, 250G | 
Double-skin Insulated (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, up to 9’0” wide | 
Limits of Use  Approved for use in HVHZ: No  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +28 PSF/-29 PSF  Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). | 
Certification Agency Certificate  FL5678_R5_C_CAC_Letter with proof of contract and proof of inspection.pdf  FL5678_R5_C_CAC_W4_C_Listing_Intertek.pdf Quality Assurance Contract Expiration Date  05/21/2028 Installation Instructions  FL5678_R5_II_101758-Rev10.pdf  Verified By: Intertek Testing Services NA, Inc.  Created by Independent Third Party:  Evaluation Reports  Created by Independent Third Party:  | 
										
	
		| 
											 | 
| 5678.2 | 
02 W4-16 C-DSIE-1F173: 3201, 3203, 250, 250G | 
Double-skin Insulated (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, 9’2” to 16’0” wide
 | 
Limits of Use  Approved for use in HVHZ: No  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +25.5 PSF/-25.5 PSF  Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). | 
Certification Agency Certificate  FL5678_R5_C_CAC_Letter with proof of contract and proof of inspection.pdf  FL5678_R5_C_CAC_W4_C_Listing_Intertek.pdf Quality Assurance Contract Expiration Date  05/21/2028 Installation Instructions  FL5678_R5_II_101760-Rev08.pdf  Verified By: Intertek Testing Services NA, Inc.  Created by Independent Third Party:  Evaluation Reports  Created by Independent Third Party:  | 
										
	
		| 
											 | 
| 5678.3 | 
03 W4-09 C-PAN-2F141: 692, 652V | 
Steel Pan (min. 24 ga.) WINDCODE® W4 Sectional Door, up to 9’0” wide
 | 
Limits of Use  Approved for use in HVHZ: No  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +25 PSF/-32 PSF  Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). | 
Certification Agency Certificate  FL5678_R5_C_CAC_Letter with proof of contract and proof of inspection.pdf  FL5678_R5_C_CAC_W4_C_Listing_Intertek.pdf Quality Assurance Contract Expiration Date  05/21/2028 Installation Instructions  FL5678_R5_II_101762-Rev10.pdf  Verified By: Intertek Testing Services NA, Inc.  Created by Independent Third Party:  Evaluation Reports  Created by Independent Third Party:  | 
										
	
		| 
											 | 
| 5678.4 | 
04 W4-16 C-PAN-2F141: 692, 652V | 
Steel Pan (min. 24 ga.) WINDCODE® W4 Sectional Door, 9’2” to 16’0” wide
 | 
Limits of Use  Approved for use in HVHZ: No  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +24 PSF/-24.5 PSF  Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). | 
Certification Agency Certificate  FL5678_R5_C_CAC_Letter with proof of contract and proof of inspection.pdf  FL5678_R5_C_CAC_W4_C_Listing_Intertek.pdf Quality Assurance Contract Expiration Date  05/21/2028 Installation Instructions  FL5678_R5_II_101781-Rev09.pdf  Verified By: Intertek Testing Services NA, Inc.  Created by Independent Third Party:  Evaluation Reports  Created by Independent Third Party:  | 
										
	
		| 
											 | 
| 5678.5 | 
05 W4-12 C-DSIE-1F447: 3200, 3220, 240, 240G | 
Double-skin Insulated (exterior skin 24 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, up to 10’2” wide
 | 
Limits of Use  Approved for use in HVHZ: No  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +25 PSF/-28 PSF  Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC).
 | 
Certification Agency Certificate  FL5678_R5_C_CAC_Letter with proof of contract and proof of inspection.pdf  FL5678_R5_C_CAC_W4_C_Listing_Intertek.pdf Quality Assurance Contract Expiration Date  05/21/2028 Installation Instructions  FL5678_R5_II_101687-Rev10.pdf  Verified By: Intertek Testing Services NA, Inc.  Created by Independent Third Party:  Evaluation Reports  Created by Independent Third Party:  | 
										
	
		| 
											 | 
| 5678.6 | 
06 W4-20 C-DSIE-1F447: 3200, 3220, 240, 240G | 
Double-skin Insulated (exterior skin 24 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, 10’4” to 20’2” wide
 | 
Limits of Use  Approved for use in HVHZ: No  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +25 PSF/-28 PSF  Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC).
 | 
Certification Agency Certificate  FL5678_R5_C_CAC_Letter with proof of contract and proof of inspection.pdf  FL5678_R5_C_CAC_W4_C_Listing_Intertek.pdf Quality Assurance Contract Expiration Date  05/21/2028 Installation Instructions  FL5678_R5_II_101682-Rev09.pdf  Verified By: Intertek Testing Services NA, Inc.  Created by Independent Third Party:  Evaluation Reports  Created by Independent Third Party:  | 
										
	
		| 
											 | 
| 5678.7 | 
07 W4-24 C-DSIE-1F447: 3200, 3220, 240, 240G | 
Double-skin Insulated (exterior skin 24 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, 20’4” to 24’2” wide
 | 
Limits of Use  Approved for use in HVHZ: No  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +25 PSF/-25 PSF  Other: This Clopay Garage Door with C-channel reinforcements has been discontinued and replaced by a version with T-strut reinforcements.
Contact Clopay customer service for T-strut Approval Numbers and Drawings.
 | 
Certification Agency Certificate  FL5678_R5_C_CAC_Letter with proof of contract and proof of inspection.pdf  FL5678_R5_C_CAC_W4_C_Listing_Intertek.pdf Quality Assurance Contract Expiration Date  05/21/2028 Installation Instructions  FL5678_R5_II_DISCONTINUED.pdf  Verified By: Intertek Testing Services NA, Inc.  Created by Independent Third Party:  Evaluation Reports  Created by Independent Third Party:  | 
										
	
		| 
											 | 
| 5678.8 | 
08 W4-10 C-DSIU-1D477: 3717, C7X17, 3718, C7X18, 3720, C7X20, 240U, 3722, C0X22 | 
Double-skin Insulated (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, up to 10’2” wide
 | 
Limits of Use  Approved for use in HVHZ: No  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +25 PSF/-25 PSF  Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC).
 | 
Certification Agency Certificate  FL5678_R5_C_CAC_Letter with proof of contract and proof of inspection.pdf  FL5678_R5_C_CAC_W4_C_Listing_Intertek.pdf Quality Assurance Contract Expiration Date  05/21/2028 Installation Instructions  FL5678_R5_II_104040-Rev03.pdf  Verified By: Intertek Testing Services NA, Inc.  Created by Independent Third Party:  Evaluation Reports  Created by Independent Third Party:  | 
										
	
		| 
											 | 
| 5678.9 | 
09 W4-12 C-PAN-1E458: 525, 525V, 525S, 524, 524V, 524S, 520, 520S, 225, 225S, 224, 224S, C5EST, C5ST, C5ESV, C5SV, C5ESS, C5SS, C4ST C4SV, C4SS, C0ST, C0SS | 
Ribbed Steel (min. 25 ga.) WINDCODE® W4 Sectional Door, up to 12’2” wide
 | 
Limits of Use  Approved for use in HVHZ: No  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +25 PSF/-25 PSF  Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC).
 | 
Certification Agency Certificate  FL5678_R5_C_CAC_Letter with proof of contract and proof of inspection.pdf  FL5678_R5_C_CAC_W4_C_Listing_Intertek.pdf Quality Assurance Contract Expiration Date  05/21/2028 Installation Instructions  FL5678_R5_II_101856-Rev13.pdf  Verified By: Intertek Testing Services NA, Inc.  Created by Independent Third Party:  Evaluation Reports  Created by Independent Third Party:  | 
										
	
		| 
											 | 
| 5678.10 | 
10 W4-16 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224S, C4ST C4SV, C4SS, C0ST, C0SS | 
Ribbed Steel (min. 24 ga.) WINDCODE® W4 Sectional Door, 12’4” to 16’2” wide
 | 
Limits of Use  Approved for use in HVHZ: No  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +25 PSF/-25 PSF  Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC).
 | 
Certification Agency Certificate  FL5678_R5_C_CAC_Letter with proof of contract and proof of inspection.pdf  FL5678_R5_C_CAC_W4_C_Listing_Intertek.pdf Quality Assurance Contract Expiration Date  05/21/2028 Installation Instructions  FL5678_R5_II_101886-Rev13.pdf  Verified By: Intertek Testing Services NA, Inc.  Created by Independent Third Party:  Evaluation Reports  Created by Independent Third Party:  | 
										
	
		| 
											 | 
| 5678.11 | 
11 W4-20 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224S, C4ST C4SV, C4SS, C0ST, C0SS | 
Ribbed Steel (min. 24 ga.) WINDCODE® W4 Sectional Door, 16’4” to 20’2” wide
 | 
Limits of Use  Approved for use in HVHZ: No  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +25 PSF/-25 PSF  Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC).
 | 
Certification Agency Certificate  FL5678_R5_C_CAC_Letter with proof of contract and proof of inspection.pdf  FL5678_R5_C_CAC_W4_C_Listing_Intertek.pdf Quality Assurance Contract Expiration Date  05/21/2028 Installation Instructions  FL5678_R5_II_102126-Rev11.pdf  Verified By: Intertek Testing Services NA, Inc.  Created by Independent Third Party:  Evaluation Reports  Created by Independent Third Party:  | 
										
	
		| 
											 | 
| 5678.12 | 
12 W4-24 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224S, C4ST C4SV, C4SS, C0ST, C0SS | 
Ribbed Steel (min. 24 ga.) WINDCODE® W4 Sectional Door, 20’4” to 24’2” wide
 | 
Limits of Use  Approved for use in HVHZ: No  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +25 PSF/-25 PSF  Other: This Clopay Garage Door with C-channel reinforcements has been discontinued and replaced by a version with T-strut reinforcements.
Contact Clopay customer service for T-strut Approval Numbers and Drawings.
 | 
Certification Agency Certificate  FL5678_R5_C_CAC_Letter with proof of contract and proof of inspection.pdf  FL5678_R5_C_CAC_W4_C_Listing_Intertek.pdf Quality Assurance Contract Expiration Date  05/21/2028 Installation Instructions  FL5678_R5_II_DISCONTINUED.pdf  Verified By: Intertek Testing Services NA, Inc.  Created by Independent Third Party:  Evaluation Reports  Created by Independent Third Party:  | 
										
	
		| 
											 | 
| 5678.13 | 
13 W4-24 C-AL-1F499: 902, 903, C2AL, C3AL | 
Service Station WINDCODE® W4 Sectional Door, up to 24’2” wide
 | 
Limits of Use  Approved for use in HVHZ: No  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +25 PSF/-25 PSF  Other: This Clopay Garage Door with C-channel reinforcements has been discontinued and replaced by a version with T-strut reinforcements.
Contact Clopay customer service for T-strut Approval Numbers and Drawings.
 | 
Certification Agency Certificate  FL5678_R5_C_CAC_Letter with proof of contract and proof of inspection.pdf  FL5678_R5_C_CAC_W4_C_Listing_Intertek.pdf Quality Assurance Contract Expiration Date  05/21/2028 Installation Instructions  FL5678_R5_II_DISCONTINUED.pdf  Verified By: Intertek Testing Services NA, Inc.  Created by Independent Third Party:  Evaluation Reports  Created by Independent Third Party:  | 
										
	
		| 
											 | 
| 5678.14 | 
14 W5-16 C-DSIE-1F447: 3200, 3220, 240, 240G | 
Double-skin Insulated (exterior skin 24 ga. min.; interior skin 27 ga. min.) WINDCODE® W5 Sectional Door, up to 16’2” wide
 | 
Limits of Use  Approved for use in HVHZ: No  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +30 PSF/-32 PSF  Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC).
 | 
Certification Agency Certificate  FL5678_R5_C_CAC_Letter with proof of contract and proof of inspection.pdf  FL5678_R5_C_CAC_W5_C_Listing_Intertek.pdf Quality Assurance Contract Expiration Date  05/21/2028 Installation Instructions  FL5678_R5_II_200040-Rev15.pdf  Verified By: Intertek Testing Services NA, Inc.  Created by Independent Third Party:  Evaluation Reports  Created by Independent Third Party:  | 
										
	
		| 
											 | 
| 5678.15 | 
15 W5-22 C-DSIE-1F447: 3200, 3220, 240, 240G | 
Double-skin Insulated (exterior skin 24 ga. min.; interior skin 27 ga. min.) WINDCODE® W5 Sectional Door, 16’4” to 22’2” wide
 | 
Limits of Use  Approved for use in HVHZ: No  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +30 PSF/-30 PSF  Other: This Clopay Garage Door with C-channel reinforcements has been discontinued and replaced by a version with T-strut reinforcements.
Contact Clopay customer service for T-strut Approval Numbers and Drawings.
 | 
Certification Agency Certificate  FL5678_R5_C_CAC_Letter with proof of contract and proof of inspection.pdf  FL5678_R5_C_CAC_W5_C_Listing_Intertek.pdf Quality Assurance Contract Expiration Date  05/21/2028 Installation Instructions  FL5678_R5_II_DISCONTINUED.pdf  Verified By: Intertek Testing Services NA, Inc.  Created by Independent Third Party:  Evaluation Reports  Created by Independent Third Party:  | 
										
	
		| 
											 | 
| 5678.16 | 
16 W5-14 C-DSIU-1D477: 3717, C7X17, 3718, C7X18, 3720, C7X20, 240U, 3722, C0X22 | 
Double-skin Insulated (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W5 Sectional Door, up to 14’2” wide
 | 
Limits of Use  Approved for use in HVHZ: No  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +30 PSF/-34 PSF  Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC).
 | 
Certification Agency Certificate  FL5678_R5_C_CAC_Letter with proof of contract and proof of inspection.pdf  FL5678_R5_C_CAC_W5_C_Listing_Intertek.pdf Quality Assurance Contract Expiration Date  05/21/2028 Installation Instructions  FL5678_R5_II_104044-Rev04.pdf  Verified By: Intertek Testing Services NA, Inc.  Created by Independent Third Party:  Evaluation Reports  Created by Independent Third Party:  | 
										
	
		| 
											 | 
| 5678.17 | 
17 W5-08 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224S, C4ST C4SV, C4SS, C0ST, C0SS | 
Ribbed Steel (min. 24 ga.) WINDCODE® W5 Sectional Door, up to 8’2” wide
 | 
Limits of Use  Approved for use in HVHZ: No  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +30 PSF/-30 PSF  Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC).
 | 
Certification Agency Certificate  FL5678_R5_C_CAC_Letter with proof of contract and proof of inspection.pdf  FL5678_R5_C_CAC_W5_C_Listing_Intertek.pdf Quality Assurance Contract Expiration Date  05/21/2028 Installation Instructions  FL5678_R5_II_101874-Rev13.pdf  Verified By: Intertek Testing Services NA, Inc.  Created by Independent Third Party:  Evaluation Reports  Created by Independent Third Party:  | 
										
	
		| 
											 | 
| 5678.18 | 
18 W5-10 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224S, C4ST C4SV, C4SS, C0ST, C0SS | 
Ribbed Steel (min. 24 ga.) WINDCODE® W5 Sectional Door, 8’4” to 10’2” wide
 | 
Limits of Use  Approved for use in HVHZ: No  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +30 PSF/-30 PSF  Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC).
 | 
Certification Agency Certificate  FL5678_R5_C_CAC_Letter with proof of contract and proof of inspection.pdf  FL5678_R5_C_CAC_W5_C_Listing_Intertek.pdf Quality Assurance Contract Expiration Date  05/21/2028 Installation Instructions  FL5678_R5_II_101875-Rev12.pdf  Verified By: Intertek Testing Services NA, Inc.  Created by Independent Third Party:  Evaluation Reports  Created by Independent Third Party:  | 
										
	
		| 
											 | 
| 5678.19 | 
19 W5-12 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224S, C4ST C4SV, C4SS, C0ST, C0SS | 
Ribbed Steel (min. 24 ga.) WINDCODE® W5 Sectional Door, 10’4” to 12’2” wide
 | 
Limits of Use  Approved for use in HVHZ: No  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +30 PSF/-30 PSF  Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC).
 | 
Certification Agency Certificate  FL5678_R5_C_CAC_Letter with proof of contract and proof of inspection.pdf  FL5678_R5_C_CAC_W5_C_Listing_Intertek.pdf Quality Assurance Contract Expiration Date  05/21/2028 Installation Instructions  FL5678_R5_II_101869-Rev12.pdf  Verified By: Intertek Testing Services NA, Inc.  Created by Independent Third Party:  Evaluation Reports  Created by Independent Third Party:  | 
										
	
		| 
											 | 
| 5678.20 | 
20 W5-16 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224S, C4ST C4SV, C4SS, C0ST, C0SS | 
Ribbed Steel (min. 24 ga.) WINDCODE® W5 Sectional Door, 12’4” to 16’2” wide
 | 
Limits of Use  Approved for use in HVHZ: No  Approved for use outside HVHZ: Yes  Impact Resistant: N/A  Design Pressure: +32 PSF/-32 PSF  Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC).
 | 
Certification Agency Certificate  FL5678_R5_C_CAC_Letter with proof of contract and proof of inspection.pdf  FL5678_R5_C_CAC_W5_C_Listing_Intertek.pdf Quality Assurance Contract Expiration Date  05/21/2028 Installation Instructions  FL5678_R5_II_101885-Rev15.pdf  Verified By: Intertek Testing Services NA, Inc.  Created by Independent Third Party:  Evaluation Reports  Created by Independent Third Party:  |