| 21067.1 |
300-309/5800/7540 Drawing 411416 |
9' Max Width x 14' Max Height. Only available with glazed top section. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +12.80/-14.80 Other: Doors with glazing shall not be used in the wind-borne debris region unless protected or unless structure is designed as partially enclosed or door is replacement door |
Installation Instructions FL21067_R6_II_411416-rB_s.pdf FL21067_R6_II_JambConnectionSupplement-OHD-411526-P01_sFL.pdf FL21067_R6_II_TrackSuppl-OHD-411059-rC_sFL.pdf Verified By: John E. Scates FLORIDA PE 51737 Created by Independent Third Party: Yes Evaluation Reports FL21067_R6_AE_Eval_Rept_OHD_301_5800_s.pdf Created by Independent Third Party: Yes |
|
|
| 21067.2 |
300-309/5800/7540 Drawing 411417 |
9' Max Width x 14' Max Height. Solid Only-No Glazing Available |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +22.90/-26.30 Other: |
Installation Instructions FL21067_R6_II_411417-rB_s.pdf FL21067_R6_II_JambConnectionSupplement-OHD-411526-P01_sFL.pdf FL21067_R6_II_TrackSuppl-OHD-411059-rC_sFL.pdf Verified By: John E. Scates FLORIDA PE 51737 Created by Independent Third Party: Yes Evaluation Reports FL21067_R6_AE_Eval_Rept_OHD_301_5800_s.pdf Created by Independent Third Party: Yes |
|
|
| 21067.3 |
300-309/5800/7540 Drawing 411418 |
9' Max Width x 14' Max Height. Only available with glazed top section. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +22.90/-26.30 Other: Doors with glazing shall not be used in the wind-borne debris region unless protected or unless structure is designed as partially enclosed or door is replacement door |
Installation Instructions FL21067_R6_II_411418-rB_s.pdf FL21067_R6_II_JambConnectionSupplement-OHD-411526-P01_sFL.pdf FL21067_R6_II_TrackSuppl-OHD-411059-rC_sFL.pdf Verified By: John E. Scates FLORIDA PE 51737 Created by Independent Third Party: Yes Evaluation Reports FL21067_R6_AE_Eval_Rept_OHD_301_5800_s.pdf Created by Independent Third Party: Yes |
|
|
| 21067.4 |
300-309/5800/7540 Drawing 411419 |
9' Max Width x 14' Max Height. Solid Only-No Glazing Available |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +26.90/-30.80 Other: |
Installation Instructions FL21067_R6_II_411419-rB_s.pdf FL21067_R6_II_JambConnectionSupplement-OHD-411526-P01_sFL.pdf FL21067_R6_II_TrackSuppl-OHD-411059-rC_sFL.pdf Verified By: John E. Scates FLORIDA PE 51737 Created by Independent Third Party: Yes Evaluation Reports FL21067_R6_AE_Eval_Rept_OHD_301_5800_s.pdf Created by Independent Third Party: Yes |
|
|
| 21067.5 |
300-309/5800/7540 Drawing 411420 |
9' Max Width x 14' Max Height. Only available with glazed top section. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +26.90/-30.80 Other: Doors with glazing shall not be used in the wind-borne debris region unless protected or unless structure is designed as partially enclosed or door is replacement door. |
Installation Instructions FL21067_R6_II_411420-rB_s.pdf FL21067_R6_II_JambConnectionSupplement-OHD-411526-P01_sFL.pdf FL21067_R6_II_TrackSuppl-OHD-411059-rC_sFL.pdf Verified By: John E. Scates FLORIDA PE 51737 Created by Independent Third Party: Yes Evaluation Reports FL21067_R6_AE_Eval_Rept_OHD_301_5800_s.pdf Created by Independent Third Party: Yes |
|
|
| 21067.6 |
300-309/5800/7540 Drawing 411421 |
9' Max Width x 14' Max Height. Solid Only-No Glazing Available |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +31.20/-35.80 Other: |
Installation Instructions FL21067_R6_II_411421-rB_s.pdf FL21067_R6_II_JambConnectionSupplement-OHD-411526-P01_sFL.pdf FL21067_R6_II_TrackSuppl-OHD-411059-rC_sFL.pdf Verified By: John E. Scates FLORIDA PE 51737 Created by Independent Third Party: Yes Evaluation Reports FL21067_R6_AE_Eval_Rept_OHD_301_5800_s.pdf Created by Independent Third Party: Yes |
|
|
| 21067.7 |
300-309/5800/7540 Drawing 411422 |
9' Max Width x 14' Max Height. Only available with glazed top section. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +31.20/-35.80 Other: Doors with glazing shall not be used in the wind-borne debris region unless protected or unless structure is designed as partially enclosed or door is replacement door. |
Installation Instructions FL21067_R6_II_411422-rB_s.pdf FL21067_R6_II_JambConnectionSupplement-OHD-411526-P01_sFL.pdf FL21067_R6_II_TrackSuppl-OHD-411059-rC_sFL.pdf Verified By: John E. Scates FLORIDA PE 51737 Created by Independent Third Party: Yes Evaluation Reports FL21067_R6_AE_Eval_Rept_OHD_301_5800_s.pdf Created by Independent Third Party: Yes |
|
|
| 21067.8 |
300-309/5800/7540 Drawing 411423 |
9' Max Width x 14' Max Height. Solid Only-No Glazing Available |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35.70/-41.00 Other: |
Installation Instructions FL21067_R6_II_411423-rB_s.pdf FL21067_R6_II_JambConnectionSupplement-OHD-411526-P01_sFL.pdf FL21067_R6_II_TrackSuppl-OHD-411059-rC_sFL.pdf Verified By: John E. Scates FLORIDA PE 51737 Created by Independent Third Party: Yes Evaluation Reports FL21067_R6_AE_Eval_Rept_OHD_301_5800_s.pdf Created by Independent Third Party: Yes |
|
|
| 21067.9 |
300-309/5800/7540 Drawing 411424 |
9' Max Width x 14' Max Height. Solid Only-No Glazing Available |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +45.30/-51.20 Other: |
Installation Instructions FL21067_R6_II_411424-rH_s.pdf FL21067_R6_II_JambConnectionSupplement-OHD-411526-P01_sFL.pdf FL21067_R6_II_TrackSuppl-OHD-411059-rC_sFL.pdf Verified By: John E. Scates FLORIDA PE 51737 Created by Independent Third Party: Yes Evaluation Reports FL21067_R6_AE_Eval_Rept_OHD_301_5800_s.pdf Created by Independent Third Party: Yes |
|
|
| 21067.10 |
300-309/5800/7540 Drawing 411425 |
10' Max Width x 14' Max Height. Solid Only-No Glazing Available |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +12.80/-14.80 Other: |
Installation Instructions FL21067_R6_II_411425-rB_s.pdf FL21067_R6_II_JambConnectionSupplement-OHD-411526-P01_sFL.pdf FL21067_R6_II_TrackSuppl-OHD-411059-rC_sFL.pdf Verified By: John E. Scates FLORIDA PE 51737 Created by Independent Third Party: Yes Evaluation Reports FL21067_R6_AE_Eval_Rept_OHD_301_5800_s.pdf Created by Independent Third Party: Yes |
|
|
| 21067.11 |
300-309/5800/7540 Drawing 411426 |
10' Max Width x 14' Max Height. Only available with glazed top section. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +12.80/-14.80 Other: Doors with glazing shall not be used in the wind-borne debris region unless protected or unless structure is designed as partially enclosed or door is replacement door. |
Installation Instructions FL21067_R6_II_411426-rB_s.pdf FL21067_R6_II_JambConnectionSupplement-OHD-411526-P01_sFL.pdf FL21067_R6_II_TrackSuppl-OHD-411059-rC_sFL.pdf Verified By: John E. Scates FLORIDA PE 51737 Created by Independent Third Party: Yes Evaluation Reports FL21067_R6_AE_Eval_Rept_OHD_301_5800_s.pdf Created by Independent Third Party: Yes |
|
|
| 21067.12 |
300-309/5800/7540 Drawing 411427 |
10' Max Width x 14' Max Height. Solid Only-No Glazing Available |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +19.20/-22.00 Other: |
Installation Instructions FL21067_R6_II_411427-rB_s.pdf FL21067_R6_II_JambConnectionSupplement-OHD-411526-P01_sFL.pdf FL21067_R6_II_TrackSuppl-OHD-411059-rC_sFL.pdf Verified By: John E. Scates FLORIDA PE 51737 Created by Independent Third Party: Yes Evaluation Reports FL21067_R6_AE_Eval_Rept_OHD_301_5800_s.pdf Created by Independent Third Party: Yes |
|
|
| 21067.13 |
300-309/5800/7540 Drawing 411428 |
10' Max Width x 14' Max Height. Only available with glazed top section. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +19.20/-22.00 Other: Doors with glazing shall not be used in the wind-borne debris region unless protected or unless structure is designed as partially enclosed or door is replacement door. |
Installation Instructions FL21067_R6_II_411428-rB_s.pdf FL21067_R6_II_JambConnectionSupplement-OHD-411526-P01_sFL.pdf FL21067_R6_II_TrackSuppl-OHD-411059-rC_sFL.pdf Verified By: John E. Scates FLORIDA PE 51737 Created by Independent Third Party: Yes Evaluation Reports FL21067_R6_AE_Eval_Rept_OHD_301_5800_s.pdf Created by Independent Third Party: Yes |
|
|
| 21067.14 |
300-309/5800/7540 Drawing 411429 |
10' Max Width x 14' Max Height. Solid Only-No Glazing Available. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +22.90/-26.30 Other: |
Installation Instructions FL21067_R6_II_411429-rB_s.pdf FL21067_R6_II_JambConnectionSupplement-OHD-411526-P01_sFL.pdf FL21067_R6_II_TrackSuppl-OHD-411059-rC_sFL.pdf Verified By: John E. Scates FLORIDA PE 51737 Created by Independent Third Party: Yes Evaluation Reports FL21067_R6_AE_Eval_Rept_OHD_301_5800_s.pdf Created by Independent Third Party: Yes |
|
|
| 21067.15 |
300-309/5800/7540 Drawing 411430 |
10' Max Width x 14' Max Height. Only available with glazed top section. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +22.90/-26.30 Other: Doors with glazing shall not be used in the wind-borne debris region unless protected or unless structure is designed as partially enclosed or door is replacement door. |
Installation Instructions FL21067_R6_II_411430-rB_s.pdf FL21067_R6_II_JambConnectionSupplement-OHD-411526-P01_sFL.pdf FL21067_R6_II_TrackSuppl-OHD-411059-rC_sFL.pdf Verified By: John E. Scates FLORIDA PE 51737 Created by Independent Third Party: Yes Evaluation Reports FL21067_R6_AE_Eval_Rept_OHD_301_5800_s.pdf Created by Independent Third Party: Yes |
|
|
| 21067.16 |
300-309/5800/7540 Drawing 411431 |
10' Max Width x 14' Max Height. Solid Only-No Glazing Available. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +26.90/-30.80 Other: |
Installation Instructions FL21067_R6_II_411431-rB_s.pdf FL21067_R6_II_JambConnectionSupplement-OHD-411526-P01_sFL.pdf FL21067_R6_II_TrackSuppl-OHD-411059-rC_sFL.pdf Verified By: John E. Scates FLORIDA PE 51737 Created by Independent Third Party: Yes Evaluation Reports FL21067_R6_AE_Eval_Rept_OHD_301_5800_s.pdf Created by Independent Third Party: Yes |
|
|
| 21067.17 |
300-309/5800/7540 Drawing 411432 |
10' Max Width x 14' Max Height. Only available with glazed top section. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +26.90/-30.80 Other: Doors with glazing shall not be used in the wind-borne debris region unless protected or unless structure is designed as partially enclosed or door is replacement door. |
Installation Instructions FL21067_R6_II_411432-rB_s.pdf FL21067_R6_II_JambConnectionSupplement-OHD-411526-P01_sFL.pdf FL21067_R6_II_TrackSuppl-OHD-411059-rC_sFL.pdf Verified By: John E. Scates FLORIDA PE 51737 Created by Independent Third Party: Yes Evaluation Reports FL21067_R6_AE_Eval_Rept_OHD_301_5800_s.pdf Created by Independent Third Party: Yes |
|
|
| 21067.18 |
300-309/5800/7540 Drawing 411433 |
10' Max Width x 14' Max Height. Solid Only-No Glazing Available |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +31.20/-35.80 Other: |
Installation Instructions FL21067_R6_II_411433-rB_s.pdf FL21067_R6_II_JambConnectionSupplement-OHD-411526-P01_sFL.pdf FL21067_R6_II_TrackSuppl-OHD-411059-rC_sFL.pdf Verified By: John E. Scates FLORIDA PE 51737 Created by Independent Third Party: Yes Evaluation Reports FL21067_R6_AE_Eval_Rept_OHD_301_5800_s.pdf Created by Independent Third Party: Yes |
|
|
| 21067.19 |
300-309/5800/7540 Drawing 411434 |
16' Max Width x 14' Max Height. Only available with glazed top section. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +12.40/-13.80 Other: Doors with glazing shall not be used in the wind-borne debris region unless protected or unless structure is designed as partially enclosed or door is replacement door. |
Installation Instructions FL21067_R6_II_411434-rB_s.pdf FL21067_R6_II_JambConnectionSupplement-OHD-411526-P01_sFL.pdf FL21067_R6_II_TrackSuppl-OHD-411059-rC_sFL.pdf Verified By: John E. Scates FLORIDA PE 51737 Created by Independent Third Party: Yes Evaluation Reports FL21067_R6_AE_Eval_Rept_OHD_301_5800_s.pdf Created by Independent Third Party: Yes |
|
|
| 21067.20 |
300-309/5800/7540 Drawing 411435 |
16' Max Width x 14' Max Height. Solid Only-No Glazing Available |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +15.30/-17.00 Other: |
Installation Instructions FL21067_R6_II_411435-rB_s.pdf FL21067_R6_II_JambConnectionSupplement-OHD-411526-P01_sFL.pdf FL21067_R6_II_TrackSuppl-OHD-411059-rC_sFL.pdf Verified By: John E. Scates FLORIDA PE 51737 Created by Independent Third Party: Yes Evaluation Reports FL21067_R6_AE_Eval_Rept_OHD_301_5800_s.pdf Created by Independent Third Party: Yes |