Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL41985-R2
Application Type Revision
Code Version 2026
Application Status Applied For
 
Comments
Archived
 
Product Manufacturer Alliance Steel Inc.
Address/Phone/Email 3333 South Council Road
Oklahoma City, OK 73179
(405) 745-7500
kshedd@allianceokc.com
 
Authorized Signature Keith Shedd
kshedd@allianceokc.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Panel Walls
Subcategory Siding
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Bala Sockalingam
Florida License PE-62240
Quality Assurance Entity Farabaugh Engineering and Testing, LLC
Quality Assurance Contract Expiration Date 12/31/2029
Validated By Yoosef Lavi, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL41985_R2_COI_CertificateIndependence.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
AISI S1002020
ASTM E15922017
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 10/15/2026
Date Validated
 
Summary of Products
FL # Model, Number or Name Description
41985.1 FW-120 Min 24 ga., max 12" wide, 1.5" deep concealed fastened wall panels
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +120/-103.5
 Other: Allowable load of +120/-103.5 psf for 22 ga. FW-120 at support spacing of 24" o.c.
Installation Instructions
 FL41985_R2_II_EvaluationReportC3088_1.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41985_R2_AE_EvaluationReportC3088_1.pdf
 Created by Independent Third Party: Yes
41985.2 PBA Panel Min. 26 ga., 36" wide, through fastened panel over open supports
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: N/A
 Other: See evaluation report for limitations and load tables.
Installation Instructions
 FL41985_R2_II_EvaluationReportC3088_2.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41985_R2_AE_EvaluationReportC3088_2.pdf
 Created by Independent Third Party: Yes
41985.3 PBM Panel Min. 26 ga., 36" wide, through fastened panel over open supports
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +N/A/-118.9
 Other: Outward load of 118.9 psf at support spacing of 24" o.c.
Installation Instructions
 FL41985_R2_II_EvaluationReportC3088_3.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41985_R2_AE_EvaluationReportC3088_3.pdf
 Created by Independent Third Party: Yes
41985.4 PBR Panel Min. 26 ga., 36" wide, through fastened panel over open supports
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +N/A/-193.8
 Other: Outward load of 193.8 psf at support spacing of 24" o.c. for Fastener Pattern 2.
Installation Instructions
 FL41985_R2_II_EvaluationReportC3088_4.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL41985_R2_AE_EvaluationReportC3088_4.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824