Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL17671-R11
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Clopay Building Products Company
Address/Phone/Email 8585 Duke Blvd.
Mason, OH 45040
(513) 770-4641
jwheeler@clopay.com
 
Authorized Signature Jim Wheeler
jwheeler@clopay.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Exterior Doors
Subcategory Sectional Exterior Door Assemblies
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report James D. Wheeler
Florida License PE-91932
Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date 12/31/2030
Validated By Gary Pfuehler
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL17671_R11_COI_Certification_of_Independence_of_Validation_Entity-Gary_Pfuehler.pdf
FL17671_R11_COI_Statement_of_Independence_of_Evaluation_Entity_JDW.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ANSI/DASMA 1082005
ANSI/DASMA 1152005
ASTM E18862005
ASTM E19962009
ASTM E3302002
TAS 2011994
TAS 2021994
TAS 2031994
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL17671_R11_Equiv_20200812 - FBC - ASTM 1886-1996 equiv.pdf
FL17671_R11_Equiv_20230712 - FBC - ASTM E330 equiv_s.pdf
 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 10/19/2025
Date Validated 10/20/2025
Date Pending FBC Approval 10/22/2025
Date Approved 12/09/2025
 
Summary of Products
          Page 1 / 2    
FL # Model, Number or Name Description
17671.1 001 W6-12 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224V, 224S, C4ST, C4SV, C4SS, C0ST, C0SS Ribbed Steel (min. 24 ga.) WINDCODE® W6 Sectional Door, up to 12’2” wide (Solid, no glazing)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +36 PSF/-42 PSF
 Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors are impact-resistant (large missile impact).
Installation Instructions
 FL17671_R11_II_104811-Rev03.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL17671_R11_AE_CBPC_150417-A.pdf
 Created by Independent Third Party: No
17671.2 002 W8-14 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224V, 224S, C4ST, C4SV, C4SS, C0ST, C0SS Ribbed Steel (min. 24 ga.) WINDCODE® W8 Sectional Door, up to 14’2” wide (Solid, no glazing)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +52 PSF/-58 PSF
 Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors are impact-resistant (large missile impact).
Installation Instructions
 FL17671_R11_II_104812-Rev02.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL17671_R11_AE_CBPC_150417-A.pdf
 Created by Independent Third Party: No
17671.3 003 W8-12 C-DSIU-1D477: 3717, C7X17, 3718, C7X18, 3720, C7X20, 240U, 3722, C0X22, 3724, C7X24, 244U, 3730 Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W8 Sectional Door, up to 12’2” wide with Optional Impact-Resistant Lites
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +52 PSF/-58 PSF
 Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
Installation Instructions
 FL17671_R11_II_104815-Rev06.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL17671_R11_AE_CBPC_150417-A-07.pdf
 Created by Independent Third Party: No
17671.4 004 W8-14 C-DSIU-1D477: 3717, C7X17, 3718, C7X18, 3720, C7X20, 240U, 3722, C0X22, 3724, C7X24, 244U, 3730 Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W8 Sectional Door, up to 14’2” wide with Optional Impact-Resistant Lites
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +52 PSF/-58 PSF
 Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
Installation Instructions
 FL17671_R11_II_104842-Rev07.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL17671_R11_AE_CBPC_150417-A-07.pdf
 Created by Independent Third Party: No
17671.5 005 W8-16 C-DSIU-1F477: 3720, C7X20, 240U, 3722, C0X22, 3724, C7X24, 244U, 3730 Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W8 Sectional Door, up to 16’2” wide with Optional Impact-Resistant Lites
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50 PSF/-58 PSF
 Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
Installation Instructions
 FL17671_R11_II_104900-Rev04.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL17671_R11_AE_CBPC_150417-A-07.pdf
 Created by Independent Third Party: No
17671.6 006 W4-18 PAN-2F153: 73, 1500, 75, 75L, 76, 76V, 190, 84A, 94, 96, 96V, 42, 48, 55, 42B, 48B, 55S, 4RST, 6RST, 4RSF, 4F, 6RSF, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV Steel Pan (min. 25 ga.) 16’2” to 18’2” wide WINDCODE® W4 Garage Door with Optional Impact-Resistant Lites
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +25 PSF/-27 PSF
 Other: Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
Installation Instructions
 FL17671_R11_II_104946-A-Rev03_s.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL17671_R11_AE_CBPC_150417-A.6.pdf
 Created by Independent Third Party: No
17671.7 007 W4-18 PAN-2F153: 73, 1500, 75, 75L, 76, 76V, 190, 84A, 94, 96, 96V, 42, 48, 55, 42B, 48B, 55S, 4RST, 6RST, 4RSF, 4F, 6RSF, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV Steel Pan (min. 25 ga.) 16’2” to 18’2” wide WINDCODE® W4 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +25 PSF/-27 PSF
 Other: Doors with standard glazing meet the wind load requirements of the building code but DO NOT meet the impact resistant requirement for windborne debris regions.
Installation Instructions
 FL17671_R11_II_104946-B-Rev03_s.pdf
 Verified By: James D. Wheeler FL PE 91932
 Created by Independent Third Party: No
Evaluation Reports
 FL17671_R11_AE_CBPC_150417-A.6.pdf
 Created by Independent Third Party: No
17671.8 008 W5-20 DSIE-1F171: 4300, 4301, 4310, HDG, HDGL, HDGF, 66, 66G, 67, 67G, 68, SP200, SF200, SE200, 6200, 6201, 6203 Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (up to 20'2" wide) WINDCODE® W5 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +30 PSF/-33 PSF
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL17671_R11_II_104945-Rev03.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL17671_R11_AE_CBPC_150417-A.pdf
 Created by Independent Third Party: No
17671.9 009 W5-20 DSIE-1F471: GD2SP, GR2SP, GD2LP, GR2LP, AR2SP, AR2LP, ED2SP, ED2LP, 4302, HDGC, 6202, MFC68, 4305, HDGR, 6205, SFR68, MFR68 Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (up to 20'2" wide) WINDCODE® W5 Garage Door
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +30 PSF/-33 PSF
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL17671_R11_II_104944-Rev02.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL17671_R11_AE_CBPC_150417-A.pdf
 Created by Independent Third Party: No
17671.10 010 W9-09 PAN-2F143: 93, 84A, 94, 98, 4F, 4RST, 48, 48B Steel Pan (min. 24 ga.) Single-Car (up to 9’0” wide) WINDCODE® W9 Garage Door with Optional Impact-Resistant Lites
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +62 PSF/-72 PSF
 Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
Installation Instructions
 FL17671_R11_II_104847-Rev02.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL17671_R11_AE_CBPC_150417-A.pdf
 Created by Independent Third Party: No
17671.11 011 W4-09 C-DSIE-1F447: 3200, EX3200, EX3200L, EX3200N, 3220, EX3220, EX3220L, EX3220N, 240, 240G Double-skin Insulated EPS (exterior skin 24 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, up to 9'2” wide
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +25 PSF/-25 PSF
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL17671_R11_II_104994-Rev04.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL17671_R11_AE_CBPC_150417-A.pdf
 Created by Independent Third Party: No
17671.12 012 W4-09 C-DSIU-1D477: 3717, EX3717, EX3717L, EX3717N C7X17, 3718, C7X18, 3720, EX3720, EN3720L, EX3720N, C7X20, 240U, 3722, EX3722, EX3722L, EX3722N, C0X22, 3724, EX3724, EX3724L, EX3724N, C7X24, 244U, 3730 Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, up to 9’2” wide
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +25 PSF/-25 PSF
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL17671_R11_II_104993-Rev05.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL17671_R11_AE_CBPC_150417-A.pdf
 Created by Independent Third Party: No
17671.13 013 W4-14 C-DSIE-1F447: 3200, EX3200, EX3200L, EX3200N, 3220, EX3220, EX3220L, EX3220N, 240, 240G Double-skin Insulated EPS (exterior skin 24 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, up to 14'2” wide
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +25 PSF/-25 PSF
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL17671_R11_II_104791-Rev04.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL17671_R11_AE_CBPC_150417-A.pdf
 Created by Independent Third Party: No
17671.14 014 W4-14 C-DSIU-1D477:3717, EX3717, EX3717L, EX3717N, C7X17, 3718, EX3717, EX3718L, EX3718N, C7X18, 3720, EX3720, EX3720L, EX3720N, C7X20, 240U, 3722, EX3722, EX3722L, EX3722N, C0X22, 3724, EX3724, EX3724L, EX3724N, C7X24, 244U, 3730 Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, up to 14’2” wide
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +25 PSF/-25 PSF
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL17671_R11_II_104956-Rev05.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL17671_R11_AE_CBPC_150417-A.pdf
 Created by Independent Third Party: No
17671.15 015 W6-14 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224V, 224S, C4ST, C4SV, C4SS, C0ST, C0SS Ribbed Steel (min. 24 ga.) WINDCODE® W6 Sectional Door, up to 14’2” wide (Solid, no glazing)
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +38 PSF/-42 PSF
 Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors are impact-resistant (large missile impact).
Installation Instructions
 FL17671_R11_II_104924-Rev03.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL17671_R11_AE_CBPC_150417-A.pdf
 Created by Independent Third Party: No
17671.16 016 W4-16 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224V, 224S, C4ST, C4SV, C4SS, C0ST, C0SS Ribbed Steel (min. 24 ga.) WINDCODE® W4 Sectional Door, up to 16’2” wide
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +25 PSF/-25 PSF
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL17671_R11_II_105032-Rev01.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL17671_R11_AE_CBPC_170405-A.pdf
 Created by Independent Third Party: No
17671.17 017 W4-20 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224V, 224S, C4ST, C4SV, C4SS, C0ST, C0SS Ribbed Steel (min. 24 ga.) WINDCODE® W4 Sectional Door, up to 20’2” wide
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +25 PSF/-25 PSF
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL17671_R11_II_105077-Rev02.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL17671_R11_AE_CBPC_170405-A.pdf
 Created by Independent Third Party: No
17671.18 018 W4-24 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224V, 224S, C4ST, C4SV, C4SS, C0ST, C0SS Ribbed Steel (min. 24 ga.) WINDCODE® W4 Sectional Door, up to 24’2” wide
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +25 PSF/-25 PSF
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL17671_R11_II_105196-Rev02.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL17671_R11_AE_CBPC_170405-A.pdf
 Created by Independent Third Party: No
17671.19 019 W4-20 C-DSIE-1F447: 3200, 3220, 240, 240G Double-skin Insulated EPS (exterior skin 24 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, up to 20'2” wide
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +25 PSF/-28 PSF
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL17671_R11_II_105198-Rev02.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL17671_R11_AE_CBPC_170405-A.pdf
 Created by Independent Third Party: No
17671.20 020 W4-24 C-DSIE-1F447: 3200, 3220, 240, 240G Double-skin Insulated EPS (exterior skin 24 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, up to 24'2” wide
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +25 PSF/-25 PSF
 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
Installation Instructions
 FL17671_R11_II_105197-Rev02.pdf
 Verified By: Scott Hamilton FL PE 63286
 Created by Independent Third Party: No
Evaluation Reports
 FL17671_R11_AE_CBPC_170405-A.pdf
 Created by Independent Third Party: No
          Page 1 / 2    
 