| 17671.1 |
001 W6-12 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224V, 224S, C4ST, C4SV, C4SS, C0ST, C0SS |
Ribbed Steel (min. 24 ga.) WINDCODE® W6 Sectional Door, up to 12’2” wide (Solid, no glazing)
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +36 PSF/-42 PSF Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors are impact-resistant (large missile impact).
|
Installation Instructions FL17671_R11_II_104811-Rev03.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL17671_R11_AE_CBPC_150417-A.pdf Created by Independent Third Party: No |
|
|
| 17671.2 |
002 W8-14 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224V, 224S, C4ST, C4SV, C4SS, C0ST, C0SS |
Ribbed Steel (min. 24 ga.) WINDCODE® W8 Sectional Door, up to 14’2” wide (Solid, no glazing)
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +52 PSF/-58 PSF Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors are impact-resistant (large missile impact).
|
Installation Instructions FL17671_R11_II_104812-Rev02.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL17671_R11_AE_CBPC_150417-A.pdf Created by Independent Third Party: No |
|
|
| 17671.3 |
003 W8-12 C-DSIU-1D477: 3717, C7X17, 3718, C7X18, 3720, C7X20, 240U, 3722, C0X22, 3724, C7X24, 244U, 3730 |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W8 Sectional Door, up to 12’2” wide with Optional Impact-Resistant Lites
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +52 PSF/-58 PSF Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
|
Installation Instructions FL17671_R11_II_104815-Rev06.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL17671_R11_AE_CBPC_150417-A-07.pdf Created by Independent Third Party: No |
|
|
| 17671.4 |
004 W8-14 C-DSIU-1D477: 3717, C7X17, 3718, C7X18, 3720, C7X20, 240U, 3722, C0X22, 3724, C7X24, 244U, 3730 |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W8 Sectional Door, up to 14’2” wide with Optional Impact-Resistant Lites
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +52 PSF/-58 PSF Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
|
Installation Instructions FL17671_R11_II_104842-Rev07.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL17671_R11_AE_CBPC_150417-A-07.pdf Created by Independent Third Party: No |
|
|
| 17671.5 |
005 W8-16 C-DSIU-1F477: 3720, C7X20, 240U, 3722, C0X22, 3724, C7X24, 244U, 3730 |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W8 Sectional Door, up to 16’2” wide with Optional Impact-Resistant Lites
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50 PSF/-58 PSF Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
|
Installation Instructions FL17671_R11_II_104900-Rev04.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL17671_R11_AE_CBPC_150417-A-07.pdf Created by Independent Third Party: No |
|
|
| 17671.6 |
006 W4-18 PAN-2F153: 73, 1500, 75, 75L, 76, 76V, 190, 84A, 94, 96, 96V, 42, 48, 55, 42B, 48B, 55S, 4RST, 6RST, 4RSF, 4F, 6RSF, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV |
Steel Pan (min. 25 ga.) 16’2” to 18’2” wide WINDCODE® W4 Garage Door with Optional Impact-Resistant Lites
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +25 PSF/-27 PSF Other: Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
|
Installation Instructions FL17671_R11_II_104946-A-Rev03_s.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL17671_R11_AE_CBPC_150417-A.6.pdf Created by Independent Third Party: No |
|
|
| 17671.7 |
007 W4-18 PAN-2F153: 73, 1500, 75, 75L, 76, 76V, 190, 84A, 94, 96, 96V, 42, 48, 55, 42B, 48B, 55S, 4RST, 6RST, 4RSF, 4F, 6RSF, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV |
Steel Pan (min. 25 ga.) 16’2” to 18’2” wide WINDCODE® W4 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25 PSF/-27 PSF Other: Doors with standard glazing meet the wind load requirements of the building code but DO NOT meet the impact resistant requirement for windborne debris regions.
|
Installation Instructions FL17671_R11_II_104946-B-Rev03_s.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL17671_R11_AE_CBPC_150417-A.6.pdf Created by Independent Third Party: No |
|
|
| 17671.8 |
008 W5-20 DSIE-1F171: 4300, 4301, 4310, HDG, HDGL, HDGF, 66, 66G, 67, 67G, 68, SP200, SF200, SE200, 6200, 6201, 6203 |
Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (up to 20'2" wide) WINDCODE® W5 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +30 PSF/-33 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL17671_R11_II_104945-Rev03.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL17671_R11_AE_CBPC_150417-A.pdf Created by Independent Third Party: No |
|
|
| 17671.9 |
009 W5-20 DSIE-1F471: GD2SP, GR2SP, GD2LP, GR2LP, AR2SP, AR2LP, ED2SP, ED2LP, 4302, HDGC, 6202, MFC68, 4305, HDGR, 6205, SFR68, MFR68 |
Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (up to 20'2" wide) WINDCODE® W5 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +30 PSF/-33 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL17671_R11_II_104944-Rev02.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL17671_R11_AE_CBPC_150417-A.pdf Created by Independent Third Party: No |
|
|
| 17671.10 |
010 W9-09 PAN-2F143: 93, 84A, 94, 98, 4F, 4RST, 48, 48B |
Steel Pan (min. 24 ga.) Single-Car (up to 9’0” wide) WINDCODE® W9 Garage Door with Optional Impact-Resistant Lites
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +62 PSF/-72 PSF Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
|
Installation Instructions FL17671_R11_II_104847-Rev02.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL17671_R11_AE_CBPC_150417-A.pdf Created by Independent Third Party: No |
|
|
| 17671.11 |
011 W4-09 C-DSIE-1F447: 3200, EX3200, EX3200L, EX3200N, 3220, EX3220, EX3220L, EX3220N, 240, 240G |
Double-skin Insulated EPS (exterior skin 24 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, up to 9'2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-25 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL17671_R11_II_104994-Rev04.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL17671_R11_AE_CBPC_150417-A.pdf Created by Independent Third Party: No |
|
|
| 17671.12 |
012 W4-09 C-DSIU-1D477: 3717, EX3717, EX3717L, EX3717N C7X17, 3718, C7X18, 3720, EX3720, EN3720L, EX3720N, C7X20, 240U, 3722, EX3722, EX3722L, EX3722N, C0X22, 3724, EX3724, EX3724L, EX3724N, C7X24, 244U, 3730 |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, up to 9’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-25 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL17671_R11_II_104993-Rev05.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL17671_R11_AE_CBPC_150417-A.pdf Created by Independent Third Party: No |
|
|
| 17671.13 |
013 W4-14 C-DSIE-1F447: 3200, EX3200, EX3200L, EX3200N, 3220, EX3220, EX3220L, EX3220N, 240, 240G |
Double-skin Insulated EPS (exterior skin 24 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, up to 14'2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-25 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL17671_R11_II_104791-Rev04.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL17671_R11_AE_CBPC_150417-A.pdf Created by Independent Third Party: No |
|
|
| 17671.14 |
014 W4-14 C-DSIU-1D477:3717, EX3717, EX3717L, EX3717N, C7X17, 3718, EX3717, EX3718L, EX3718N, C7X18, 3720, EX3720, EX3720L, EX3720N, C7X20, 240U, 3722, EX3722, EX3722L, EX3722N, C0X22, 3724, EX3724, EX3724L, EX3724N, C7X24, 244U, 3730 |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, up to 14’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-25 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL17671_R11_II_104956-Rev05.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL17671_R11_AE_CBPC_150417-A.pdf Created by Independent Third Party: No |
|
|
| 17671.15 |
015 W6-14 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224V, 224S, C4ST, C4SV, C4SS, C0ST, C0SS |
Ribbed Steel (min. 24 ga.) WINDCODE® W6 Sectional Door, up to 14’2” wide (Solid, no glazing)
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +38 PSF/-42 PSF Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors are impact-resistant (large missile impact). |
Installation Instructions FL17671_R11_II_104924-Rev03.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL17671_R11_AE_CBPC_150417-A.pdf Created by Independent Third Party: No |
|
|
| 17671.16 |
016 W4-16 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224V, 224S, C4ST, C4SV, C4SS, C0ST, C0SS |
Ribbed Steel (min. 24 ga.) WINDCODE® W4 Sectional Door, up to 16’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-25 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL17671_R11_II_105032-Rev01.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL17671_R11_AE_CBPC_170405-A.pdf Created by Independent Third Party: No |
|
|
| 17671.17 |
017 W4-20 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224V, 224S, C4ST, C4SV, C4SS, C0ST, C0SS |
Ribbed Steel (min. 24 ga.) WINDCODE® W4 Sectional Door, up to 20’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-25 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL17671_R11_II_105077-Rev02.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL17671_R11_AE_CBPC_170405-A.pdf Created by Independent Third Party: No |
|
|
| 17671.18 |
018 W4-24 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224V, 224S, C4ST, C4SV, C4SS, C0ST, C0SS |
Ribbed Steel (min. 24 ga.) WINDCODE® W4 Sectional Door, up to 24’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-25 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL17671_R11_II_105196-Rev02.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL17671_R11_AE_CBPC_170405-A.pdf Created by Independent Third Party: No |
|
|
| 17671.19 |
019 W4-20 C-DSIE-1F447: 3200, 3220, 240, 240G |
Double-skin Insulated EPS (exterior skin 24 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, up to 20'2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-28 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL17671_R11_II_105198-Rev02.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL17671_R11_AE_CBPC_170405-A.pdf Created by Independent Third Party: No |
|
|
| 17671.20 |
020 W4-24 C-DSIE-1F447: 3200, 3220, 240, 240G |
Double-skin Insulated EPS (exterior skin 24 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, up to 24'2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-25 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL17671_R11_II_105197-Rev02.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL17671_R11_AE_CBPC_170405-A.pdf Created by Independent Third Party: No |