| 9555.1 |
5V Panel |
29 ga., 24" wide, through fastened panel over wood supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-70.25 Other: Uplift load of 70.25 psf @ support spacing of 24" o.c. |
Installation Instructions FL9555_R5_II_EvaluationReportC2373_1.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL9555_R5_AE_EvaluationReportC2373_1.pdf Created by Independent Third Party: Yes |
|
|
| 9555.2 |
7/8" Corrugated Panels |
Min. 26 ga., maximum 34.67" wide coverage through fastened roof panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +110.5/-140 Other: Maximum uplift load of 140 psf for 24 ga. panel at support spacing of 2’ o.c. |
Installation Instructions FL9555_R5_II_EvaluationReportC2373_2.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL9555_R5_AE_EvaluationReportC2373_2.pdf Created by Independent Third Party: Yes |
|
|
| 9555.3 |
MasterRib Panel |
26 ga., 36" wide, through fastened panel over steel supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-47.2 Other: Uplift load of 47.2 psf @ support spacing of 60" o.c. |
Installation Instructions FL9555_R5_II_EvaluationReportC2373_3.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL9555_R5_AE_EvaluationReportC2373_3.pdf Created by Independent Third Party: Yes |
|
|
| 9555.4 |
MasterRib Panel |
29 ga., 36" wide, through fastened panel over steel supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +27.1/-37.7 Other: Design load of 27.1 & -37.7 psf at support spacing of 48" o.c. |
Installation Instructions FL9555_R5_II_EvaluationReportC2373_4.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL9555_R5_AE_EvaluationReportC2373_4.pdf Created by Independent Third Party: Yes |
|
|
| 9555.5 |
MasterRib Panel |
29 ga., 36" wide, through fastened panel over wood supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +27.1/-36.2 Other: Design load of 27.1 & -36.2 psf at support spacing of 48" o.c. |
Installation Instructions FL9555_R5_II_EvaluationReportC2373_5.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL9555_R5_AE_EvaluationReportC2373_5.pdf Created by Independent Third Party: Yes |
|
|
| 9555.6 |
MasterRib Panels |
29 ga., 36" wide, through fastened panel over nom. 1" x 4" wood supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-138.9 Other: Uplift load of 138.9 psf @ support spacing of 24" o.c. |
Installation Instructions FL9555_R5_II_EvaluationReportC2373_6.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL9555_R5_AE_EvaluationReportC2373_6.pdf Created by Independent Third Party: Yes |
|
|
| 9555.7 |
ML200 |
Max 16" wide, min 24 ga. standing seam panel over open purlins |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-120 Other: Uplift load of 120 psf at support spacing of 20" o.c. |
Installation Instructions FL9555_R5_II_EvaluationReportC2373_7.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL9555_R5_AE_EvaluationReportC2373_7.pdf Created by Independent Third Party: Yes |
|
|
| 9555.8 |
PBR Panel |
Min. 26 ga., 36" wide, through fastened roof panel over open steel supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +96/-163 Other: Design loads of 96 & -163 psf at support spacing of 20" o.c. |
Installation Instructions FL9555_R5_II_EvaluationReportC2373_8.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL9555_R5_AE_EvaluationReportC2373_8.pdf Created by Independent Third Party: Yes |
|
|
| 9555.9 |
TS-324 Panel |
Min 24 ga., 24" wide standing seam roof panel |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-183.3 Other: Maximum uplift load of 183.3 psf @ support spacing of 24" o.c. with QuadLok seam and BA Series clip. |
Installation Instructions FL9555_R5_II_EvaluationReportC2373_9.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL9555_R5_AE_EvaluationReportC2373_9.pdf Created by Independent Third Party: Yes |