| 26012.1 |
1615/1617 SGD |
144x96 w/Insulated Laminated Glass |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: LC-PG50 |
Certification Agency Certificate FL26012_R13_C_CAC_APC (16613) 1615-1617 SGD (041727).pdf Quality Assurance Contract Expiration Date 04/17/2027 Installation Instructions FL26012_R13_II_08-03131C.pdf Verified By: Luis R. Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL26012_R13_AE_514040D.pdf Created by Independent Third Party: Yes |
|
|
| 26012.2 |
1615/1617 SGD |
106x96 Insulated Glass |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: R-PG40 |
Certification Agency Certificate FL26012_R13_C_CAC_MI Windows - 1615-1617 SGD (3) Feb. 2024 (ext.5).pdf Quality Assurance Contract Expiration Date 05/05/2029 Installation Instructions FL26012_R13_II_08-03132B.pdf Verified By: Luis R. Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL26012_R13_AE_514041B.pdf Created by Independent Third Party: Yes |
|
|
| 26012.3 |
1615/1617 SGD |
71x82 Insulated Laminated Glass |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +60/-60 Other: R-PG60 |
Certification Agency Certificate FL26012_R13_C_CAC_APC(16465)AI-03810-V1 REV. 3(REISSUE-56);REF. AI-04159-D1(REISSUE 56)_1615-1617 SGD(121328).pdf Quality Assurance Contract Expiration Date 12/13/2028 Installation Instructions FL26012_R13_II_08-03129B.pdf Verified By: Luis R. Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL26012_R13_AE_514038C.pdf Created by Independent Third Party: Yes |
|
|
| 26012.4 |
1615/1617 SGD |
187x80 Insulated Glass |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +20/-20 Other: R-PG20 |
Certification Agency Certificate FL26012_R13_C_CAC_APC (16607) 1615-1617 SGD (030927).pdf Quality Assurance Contract Expiration Date 03/09/2027 Installation Instructions FL26012_R13_II_08-03133B.pdf Verified By: Luis R. Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL26012_R13_AE_514042C.pdf Created by Independent Third Party: Yes |
|
|
| 26012.5 |
1615/1617 SGD |
144x96 Insulated Laminated Glass, Impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: LC-PG50, Missile Level D, Wind Zone 3. Glazing shall be bedded in Pecora 896 sealant. |
Certification Agency Certificate FL26012_R13_C_CAC_APC (16612) 1615-1617 SGD (041327).pdf Quality Assurance Contract Expiration Date 04/13/2027 Installation Instructions FL26012_R13_II_08-03127C.pdf Verified By: Luis R. Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL26012_R13_AE_514036D.pdf Created by Independent Third Party: Yes |
|
|
| 26012.6 |
1615/1617 SGD |
96x96 Insulated Glass |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: LC-PG50 |
Certification Agency Certificate FL26012_R13_C_CAC_APC (17201) 1615 SGD (032327).pdf Quality Assurance Contract Expiration Date 03/23/2027 Installation Instructions FL26012_R13_II_08-03130B.pdf Verified By: Luis R. Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL26012_R13_AE_514039C.pdf Created by Independent Third Party: Yes |
|
|
| 26012.7 |
1615/1617 SGD |
187x96 Insulated Glass |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +15/-15 Other: R-PG15 |
Certification Agency Certificate FL26012_R13_C_CAC_APC(16734)H1401.01-109-47-R0_1615-1617 SGD(051827).pdf Quality Assurance Contract Expiration Date 05/18/2027 Installation Instructions FL26012_R13_II_08-03289.pdf Verified By: Luis R. Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL26012_R13_AE_514262A.pdf Created by Independent Third Party: Yes |
|
|
| 26012.8 |
1615/1617 SGD |
139x96 Insulated Glass |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-30 Other: LC-PG30 |
Certification Agency Certificate FL26012_R13_C_CAC_APC(16697)H1399.01-109-47-R0_1615-1617 SGD(051827).pdf Quality Assurance Contract Expiration Date 05/18/2027 Installation Instructions FL26012_R13_II_08-03438A.pdf Verified By: Luis R Lomas, PE PE-625114 Created by Independent Third Party: Yes Evaluation Reports FL26012_R13_AE_514442A.pdf Created by Independent Third Party: Yes |
|
|
| 26012.9 |
1615/1617 SGD |
142x96 Insulated Glass |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +35/-35 Other: LC-PG35 |
Certification Agency Certificate FL26012_R13_C_CAC_APC(16735)H1400.01-109-47-R0_1615-1617 SGD(051827).pdf Quality Assurance Contract Expiration Date 05/18/2027 Installation Instructions FL26012_R13_II_08-03437A.pdf Verified By: Luis R Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL26012_R13_AE_514441A.pdf Created by Independent Third Party: Yes |
|
|
| 26012.10 |
1615/1617 SGD |
139x96 Insulated Glass XOX |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: LC-PG50 |
Certification Agency Certificate FL26012_R13_C_CAC_APC(16874)H1402.01-109-47-R1_1615-1617 SGD(082327).pdf Quality Assurance Contract Expiration Date 08/23/2027 Installation Instructions FL26012_R13_II_08-03687A.pdf Verified By: Luis R. Lomas, PE PE-62514 Created by Independent Third Party: Yes Evaluation Reports FL26012_R13_AE_514817A.pdf Created by Independent Third Party: Yes |
|
|
| 26012.11 |
1615/1617 SGD |
106x82 Insulated Glass OXO |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +45/-45 Other: R-PG45. Products shall be glazed in accordance with E1300 with safety glazing. |
Certification Agency Certificate FL26012_R13_C_CAC_APC(16250)A1-03958-B1_1615-1617 SGD(121727).pdf Quality Assurance Contract Expiration Date 12/17/2027 Installation Instructions FL26012_R13_II_27488.10-1001 - 1615 OXO SGD 106x82.pdf Verified By: MIchael D. Stremmel, PE PE-65868 Created by Independent Third Party: Yes Evaluation Reports FL26012_R13_AE_27488.10-107-16-R0 - MI Windows 1615 OXO SGD.pdf Created by Independent Third Party: Yes |
|
|
| 26012.12 |
1615/1617 SGD |
96x96 Insulated Laminated Glass XX |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: LC-PG50, Missile Level D, Wind Zone 3. Glazing shall be 5/32" tempered, aluminum box spacer, 5/32"-0.090" PVB - 5/32" annealed laminated glass. Glazing bite is 1/2" and glazing is bedded in Pecora 896 sealant. |
Certification Agency Certificate FL26012_R13_C_CAC_APC(20591)11713.02-106-12-R3,11713.02-106-12-R3_1615-1617 SGD(113027).pdf FL26012_R13_C_CAC_APC(21660)XO-OX WAIVER 11713.02-106-12-R3_1615-1617 SGD(113027).pdf Quality Assurance Contract Expiration Date 11/30/2027 Installation Instructions FL26012_R13_II_27488.15-1002R1 - 1615 SGD XX - XO 96x96 Impact.pdf Verified By: Michael D. Stremmel, PE PE-65868 Created by Independent Third Party: Yes Evaluation Reports FL26012_R13_AE_27488.15-107-16-R1 - MI Windows 1615 XX - XO SGD.pdf Created by Independent Third Party: Yes |
|
|
| 26012.13 |
1615/1617 SGD |
96x96 Insulated Glass XX |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: LC-PG50. Product shall be glazed in accordance with E1300 with safety glazing. |
Certification Agency Certificate FL26012_R13_C_CAC_APC(20634)12006.09-16-12-R0_1615-1617 SGD(113027).pdf FL26012_R13_C_CAC_MI Windows - 1615-1617 SGD (17a) Mar. 2024.pdf Quality Assurance Contract Expiration Date 11/30/2027 Installation Instructions FL26012_R13_II_27488.15-1001R1 - 1615 SGD XX - XO 96x96 non-Impact.pdf Verified By: Michael D. Stremmel, PE PE-65868 Created by Independent Third Party: Yes Evaluation Reports FL26012_R13_AE_27488.15-107-16-R1 - MI Windows 1615 XX - XO SGD.pdf Created by Independent Third Party: Yes |