| 29467.1 |
7/8" Corrugated Panels |
Min 26 ga., max 29.33" wide coverage through fastened panel over 15/32" thick plywood or 7/16" thick OSB |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-115.2 Other: Uplift load of 41.6 psf @ fastener spacing of 24" o.c. & 115.2 psf @ fastener spacing of 8" o.c. |
Installation Instructions FL29467_R1_II_EvaluationReportC2402_1.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL29467_R1_AE_EvaluationReportC2402_1.pdf Created by Independent Third Party: Yes |
|
|
| 29467.2 |
7/8" Corrugated Panels |
Min 24 ga., max 34.67" wide coverage through fastened panel over 15/32" thick plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-177.1 Other: Uplift load of 45 psf @ fastener spacing of 36" o.c. & 177.1 psf @ fastener spacing of 8" o.c. |
Installation Instructions FL29467_R1_II_EvaluationReportC2402_2.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL29467_R1_AE_EvaluationReportC2402_2.pdf Created by Independent Third Party: Yes |
|
|
| 29467.3 |
Aluminum PermaLok |
Max 16" wide, nom 0.032" thick (min.) aluminum concealed fastener roof panel over min 15/32" thick plywood deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-78.5 Other: Uplift load of 37.5 psf at fastener spacing of 5-3/16" o.c. and 78.5 psf at fastener spacing of 5-3/16" o.c. with adhesive |
Installation Instructions FL29467_R1_II_EvaluationReportC2402_3.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL29467_R1_AE_EvaluationReportC2402_3.pdf Created by Independent Third Party: Yes |
|
|
| 29467.4 |
Aluminum SL175 |
Max 18" wide, nom 0.032" thick (min.) aluminum snap-lock standing seam panel over min 15/32" thick plywood deck. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-93.5 Other: Uplift load of 93.5 psf at clip spacing of 24" o.c. |
Installation Instructions FL29467_R1_II_EvaluationReportC2402_4.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL29467_R1_AE_EvaluationReportC2402_4.pdf Created by Independent Third Party: Yes |