| 15279.1 |
001 W3-09 DSIE-1A171: 2050, 2051, 2053, 4050, 4051, 4053, 62, 64, 65, 62G, 62LG, 64G, SDP38, SFL38, SRP38, 134, 135, 136, 6130, 6131, 6133 |
1-3/8" Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 29 ga. min.) Single-Car (up to 9’0” wide) WINDCODE® W3 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +20 PSF/-21 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL15279_R12_II_101655-Rev15.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL15279_R12_AE_CCER_230821-A.pdf Created by Independent Third Party: No |
|
|
| 15279.2 |
002 W3-09 DSIE-1A471: GD1SP, GR1SP, GD1LP, GR1LP, AR1SP, AR1LP, ED1SP, ED1LP, 4132, 2132, 6132, SFC38, MFC38 |
Gallery/Artistry/Expressions: 1-3/8" Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9’0” wide) WINDCODE® W3 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +20 PSF/-21 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL15279_R12_II_103952-Rev03.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL15279_R12_AE_CCER_230821-A.pdf Created by Independent Third Party: No |
|
|
| 15279.3 |
003 W3-09 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 |
Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9’0” wide) WINDCODE® W3 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +20 PSF/-20 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL15279_R12_II_104175-Rev04.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL15279_R12_AE_CCER_230821-A.pdf Created by Independent Third Party: No |
|
|
| 15279.4 |
004 W3-16 DSIE-1A171: 2050, 2051, 2053, 4050, 4051, 4053, 62, 64, 65, 62G, 62LG, 64G, SDP38, SFL38, SRP38, 134, 135, 136, 6130, 6131, 6133 |
1-3/8" Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 29 ga. min.) Double-Car (9’2” to 16’0” wide) WINDCODE® W3 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +20 PSF/-21 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL15279_R12_II_101820-Rev16.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL15279_R12_AE_CCER_230821-A.pdf Created by Independent Third Party: No |
|
|
| 15279.5 |
005 W3-16 DSIE-1A471: GD1SP, GR1SP, GD1LP, GR1LP, AR1SP, AR1LP, ED1SP, ED1LP, 4132, 2132, 6132, SFC38, MFC38 |
Gallery/Artistry/Expressions: 1-3/8" Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (9’2” up to 16’0” wide) WINDCODE® W3 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +20 PSF/-21 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL15279_R12_II_104028-Rev03.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL15279_R12_AE_CCER_230821-A.pdf Created by Independent Third Party: No |
|
|
| 15279.6 |
006 W3-16 DSIU-1A171: 9130, 9131, 9133, HDP13, HDPF13, HDPL13, 7130, 7131, 7133, 8130, 8131, 8133 |
Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (9’2” to 16’0” wide) WINDCODE® W3 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +20 PSF/-21 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL15279_R12_II_104168-Rev04.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL15279_R12_AE_CCER_230821-A.pdf Created by Independent Third Party: No |
|
|
| 15279.7 |
007 W3-16 PAN-2F153: 73, 4F, 1500, 75, 190, 84A, 94, 42, 48, 55, 42B, 48B, 55S, 4RST, 6RST, 4RSF, 6RSF |
Steel Pan (min. 25 ga.) Double-Car (9’2” to 16’0” wide) WINDCODE® W3 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +20 PSF/-21 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL15279_R12_II_101308-Rev15.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL15279_R12_AE_CCER_230821-B.pdf Created by Independent Third Party: No |
|
|
| 15279.8 |
008 W4-09 DSIE-1F171: 4300, 4301, 4310, 4400, 4401, HDG, HDGL, HDGF, 66, 66G, 67, 67G, 68, SP200, SF200, SE200, 6200, 6201, 6203 |
2" Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9'0" wide) WINDCODE® W4 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +28 PSF/-29 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL15279_R12_II_101652-B-Rev12.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL15279_R12_AE_CCER_250610-B-01.pdf Created by Independent Third Party: No |
|
|
| 15279.9 |
009 W4-09 DSIE-1F471: GD2SP, GR2SP, GD2LP, GR2LP, AR2SP, AR2LP, ED2SP, ED2LP, 4302, HDGC, 6202, SFC68, MFC68 |
Gallery/Artistry/Expressions: 2" Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9’0” wide) WINDCODE® W4 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +28 PSF/-29 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions.
|
Installation Instructions FL15279_R12_II_103969-B-Rev04.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL15279_R12_AE_CCER_230821-A.pdf Created by Independent Third Party: No |
|
|
| 15279.10 |
010 W4-09 DSIU-1F171: 9200, 9201, 9203, HDP20, HDPF20, HDPL20, 7200, 7201, 7203, 8200, 8201, 8203 |
Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Single-Car (up to 9'0" wide) WINDCODE® W4 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +28 PSF/-29 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL15279_R12_II_104183-Rev04.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL15279_R12_AE_CCER_250610-B-01.pdf Created by Independent Third Party: No |
|
|
| 15279.11 |
011 W4-09 DSIUO-1K479: Canyon Ridge/Brookstone |
Double Skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27ga. min.) with Overlay Single-Car (up to 9’0” wide) WINDCODE® W4 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +27 PSF/-29 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL15279_R12_II_104456-Rev02.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL15279_R12_AE_CCER_230821-A.pdf Created by Independent Third Party: No |
|
|
| 15279.12 |
012 W4-09 PAN-2F151: 73, 4F, 1500, 75, 190, 84A, 94, 96, 96V, 75L, 76, 76V, 42, 48, 55, 42B, 48B, 55S, 4RST, 6RST, 4RSF, 6RSF, 2RST, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV |
Steel Pan (min. 25 ga.) Single-Car (up to 9’0” wide) WINDCODE® W4 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25 PSF/-32 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. |
Installation Instructions FL15279_R12_II_300159-B-Rev19.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL15279_R12_AE_CCER_250622-B-01.pdf Created by Independent Third Party: No |
|
|
| 15279.13 |
013 W4-09 PAN-2F441: GD4S, GR4S, GD4L, GR4L, GD4SV, GR4SV, GD4LV, GR4LV, MR4S, MR4L, MR4SV, MR4LV, AR4S, AR4L, AR4SV, AR4LV, ED4S, ED4L, ED4SV, ED4LV |
Gallery/Artistry/Expressions: Steel Pan (min. 24 ga.) Single-Car (up to 9’0” wide) WINDCODE® W4 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25 PSF/-32 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions.
|
Installation Instructions FL15279_R12_II_103486-B-Rev11.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL15279_R12_AE_CCER_250616-B-01.pdf Created by Independent Third Party: No |
|
|
| 15279.14 |
014 W4-09 SPO-2F449: Grand Harbor, Stone Manor |
Steel Pan (min. 24 ga.) with Overlay Single-Car (up to 9’0”wide) WINDCODE® W4 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-32 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC). |
Installation Instructions FL15279_R12_II_103549-Rev08.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL15279_R12_AE_CCER_230821-A.pdf Created by Independent Third Party: No |
|
|
| 15279.15 |
015 W4-16 DSIE-1F171: 4300, 4301, 4310, 4400, 4401, HDG, HDGL, HDGF, 66, 66G, 67, 67G, 68, SP200, SF200, SE200, 6200, 6201, 6203 |
2" Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (9'2" to 16'0" wide) WINDCODE® W4 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25.5 PSF/-25.5 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions.
|
Installation Instructions FL15279_R12_II_101481-B-Rev15.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL15279_R12_AE_CCER_250610-B-01.pdf Created by Independent Third Party: No |
|
|
| 15279.16 |
016 W4-16 DSIE-1F471: GD2SP, GR2SP, GD2LP, GR2LP, AR2SP, AR2LP, ED2SP, ED2LP, 4302, HDGC, 6202, SFC68, MFC68 |
Gallery/Artistry/Expressions: 2" Double-skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (9’2” up to 16’0” wide) WINDCODE® W4 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25 PSF/-25 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions.
|
Installation Instructions FL15279_R12_II_104029-B-Rev06.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL15279_R12_AE_CCER_230821-A.pdf Created by Independent Third Party: No |
|
|
| 15279.17 |
017 W4-16 DSIEO-1F479: Coachman/Settlers/Affinity |
Double Skin Insulated EPS (exterior skin 27 ga. min.; interior skin 27ga. min.) with Overlay Double-Car (up to 16’0” wide) WINDCODE® W4 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25 PSF/-25 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC). |
Installation Instructions FL15279_R12_II_103046-Rev09.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL15279_R12_AE_CCER_250618-B-01.pdf Created by Independent Third Party: No |
|
|
| 15279.18 |
018 W4-16 DSIU-1F171: 9200, 9201, 9203, HDP20, HDPF20, HDPL20, 7200, 7201, 7203, 8200, 8201, 8203 |
Double-skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27 ga. min.) Double-Car (9'2" to 16'0" wide) WINDCODE® W4 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25.5 PSF/-25.5 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL15279_R12_II_104169-Rev04.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL15279_R12_AE_CCER_250610-B-01.pdf Created by Independent Third Party: No |
|
|
| 15279.19 |
019 W4-16 DSIUO-1K479: Canyon Ridge/Brookstone |
Double Skin Insulated PUR (exterior skin 27 ga. min.; interior skin 27ga. min.) with Overlay Double-Car (9’2” to 16’0” wide) WINDCODE® W4 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-25 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL15279_R12_II_104457-Rev04.pdf Verified By: Mark Westerfield FL PE 48495 Created by Independent Third Party: No Evaluation Reports FL15279_R12_AE_CCER_230821-A.pdf Created by Independent Third Party: No |
|
|
| 15279.20 |
020 W4-16 PAN-2F153: 73, 4F, 1500, 75, 190, 84A, 94, 42, 48, 55, 4RST, 6RST, 4RSF, 6RSF, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV |
Steel Pan (min. 25 ga.) Double-Car (9’2” to 16’0” wide) WINDCODE® W4 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +24 PSF/-24.5 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions.
|
Installation Instructions FL15279_R12_II_101711-B-Rev18.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL15279_R12_AE_CCER_250622-B-01.pdf Created by Independent Third Party: No |