Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL38135-R4
Application Type Revision
Code Version 2026
Application Status Pending FBC Approval
 
Comments
Archived
 
Product Manufacturer Vision Hollow Metal Limited
Address/Phone/Email 400 Zenway BVLD.
Woodbridge, NON-US
(905) 851-1121
Nick@vhmetal.com
 
Authorized Signature Nick Siragusa
Nick@vhmetal.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Robert J. Amoruso
Florida License PE-49752
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2027
Validated By Steven M. Urich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL38135_R4_COI_ACE-CI-1096_Rev2_VHM Steel Doors_ss.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E188613a
ASTM E199617
ASTM E283-04 (2012)2012
ASTM E3302014
ASTM E331-00 (2023)2023
TAS 2011994
TAS 2021994
TAS 2031994
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL38135_R4_Equiv_ACE-EER-1096_Rev2_VHM Steel Doors_ss.pdf
 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 10/05/2026
Date Validated 10/06/2026
Date Pending FBC Approval 10/14/2026
 
Summary of Products
FL # Model, Number or Name Description
38135.1 LS1875 STEEL DOOR LS1875 STEEL DOOR-OUTSWING- IMPACT RATED - Using Subframe and Clip Anchoring
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +75/-75
 Other: All installation fasteners and associated connectors (if applicable) to be corrosion resistant, and/or have a corrosion resistant coating. When exposed to saltwater environments within 3,000 feet of a saltwater coastline, installation fasteners must meet the requirements of Section 1711, 9th Edition (2026) FBC and Section R332, 9th Edition (2026) FRC when applicable.
Installation Instructions
 FL38135_R4_II_VHM0001_RevD_LS1875_ss.pdf
 Verified By: Robert J Amoruso P.E. PE - 49752
 Created by Independent Third Party: Yes
Evaluation Reports
 FL38135_R4_AE_ACE-PER-1096_Rev2_VHM Steel Doors_ss.pdf
 Created by Independent Third Party: Yes
38135.2 LS2075 STEEL DOOR LS2075 STEEL DOOR-OUTSWING- IMPACT RATED - Using Subframe and Clip Anchoring
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +75/-75
 Other: All installation fasteners and associated connectors (if applicable) to be corrosion resistant, and/or have a corrosion resistant coating. When exposed to saltwater environments within 3,000 feet of a saltwater coastline, installation fasteners must meet the requirements of Section 1711, 9th Edition (2026) FBC and Section R332, 9th Edition (2026) FRC when applicable.
Installation Instructions
 FL38135_R4_II_VHM0002_RevD_LS2075_ss.pdf
 Verified By: Robert J Amoruso P.E. PE - 49752
 Created by Independent Third Party: Yes
Evaluation Reports
 FL38135_R4_AE_ACE-PER-1096_Rev2_VHM Steel Doors_ss.pdf
 Created by Independent Third Party: Yes
38135.3 LS2075 STEEL DOOR LS2075 STEEL DOOR INSWING/OUTSWING-IMPACT RATED - Using Subframe and Clip Anchoring
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: N/A
 Other: Design Pressure: Inswing DP = +50/-60 psf; Outswing = +/-55 psf. All installation fasteners and associated connectors (if applicable) to be corrosion resistant, and/or have a corrosion resistant coating. When exposed to saltwater environments within 3,000 feet of a saltwater coastline, installation fasteners must meet the requirements of Section 1711, 9th Edition (2026) FBC and Section R332, 9th Edition (2026) FRC when applicable.
Installation Instructions
 FL38135_R4_II_VHM0003_RevD_LS2075_ss.pdf
 Verified By: Robert J Amoruso P.E. PE - 49752
 Created by Independent Third Party: Yes
Evaluation Reports
 FL38135_R4_AE_ACE-PER-1096_Rev2_VHM Steel Doors_ss.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts: