| 15058.1 |
15058.01 Rib Doors, Commercial |
Sectional steel doors with or without vinyl back or steel back polystyrene insulation and with an option for aluminum framed full view sections, for widths 6'-00" through 8'-08" see drawing for applicable pressures. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: Sectional doors provided for wind load applications. |
Installation Instructions FL15058_R7_II_BackJambAttachment_s.pdf FL15058_R7_II_Z2-06-61317.pdf Verified By: John E. Scates, P.E. FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL15058_R7_AE_FL15058 Eval_Rept_cpan_s.pdf Created by Independent Third Party: Yes |
|
|
| 15058.2 |
15058.02 Rib Doors, Commercial |
Sectional steel doors with or without vinyl back or steel back polystyrene insulation and with an option for aluminum framed full view sections, for widths 6'-00" through 10'-06" see drawing for applicable pressures. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: Sectional doors provided for wind load applications. |
Installation Instructions FL15058_R7_II_BackJambAttachment_s.pdf FL15058_R7_II_Z9-09-61317.pdf Verified By: John E. Scates, P.E. FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL15058_R7_AE_FL15058 Eval_Rept_cpan_s.pdf Created by Independent Third Party: Yes |
|
|
| 15058.3 |
15058.03 Rib Doors, Commercial |
Sectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 6'-00" through 10'-08" see drawing for applicable pressures.
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Sectional doors provided for wind load and impact applications. |
Installation Instructions FL15058_R7_II_BackJambAttachment_s.pdf FL15058_R7_II_Z11i-09-61517.pdf Verified By: John E. Scates, P.E. FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL15058_R7_AE_FL15058 Eval_Rept_cpan_s.pdf Created by Independent Third Party: Yes |
|
|
| 15058.4 |
15058.04 Rib Doors, Commercial |
Sectional steel doors with or without vinyl back or steel back polystyrene insulation and with an option for aluminum framed full view sections, for widths 6'-00" through 12'-11" see drawing for applicable pressures. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: Sectional doors provided for wind load applications. |
Installation Instructions FL15058_R7_II_BackJambAttachment_s.pdf FL15058_R7_II_Z5-10-61317.pdf Verified By: John E. Scates, P.E. FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL15058_R7_AE_FL15058 Eval_Rept_cpan_s.pdf Created by Independent Third Party: Yes |
|
|
| 15058.5 |
15058.05 Rib Doors, Commercial |
Sectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 6'-00" through 10'-08" see drawing for applicable pressures. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Sectional doors provided for wind load and impact applications. |
Installation Instructions FL15058_R7_II_BackJambAttachment_s.pdf FL15058_R7_II_Z8i-10-61517.pdf Verified By: John E. Scates, P.E. FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL15058_R7_AE_FL15058 Eval_Rept_cpan_s.pdf Created by Independent Third Party: Yes |
|
|
| 15058.6 |
15058.06 Rib Doors, Commercial |
Sectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 10'-02" through 14'-06" see drawing for applicable pressures.
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Sectional doors provided for wind load and impact applications. |
Installation Instructions FL15058_R7_II_BackJambAttachment_s.pdf FL15058_R7_II_Z8i-12-61517.pdf Verified By: John E. Scates, P.E. FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL15058_R7_AE_FL15058 Eval_Rept_cpan_s.pdf Created by Independent Third Party: Yes |
|
|
| 15058.7 |
15058.07 Rib Doors, Commercial |
Sectional steel doors with or without vinyl back or steel back polystyrene insulation and with an option for aluminum framed full view sections, for widths 10'-06" through 18'-02" see drawing for applicable pressures. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: Sectional doors provided for wind load applications. |
Installation Instructions FL15058_R7_II_BackJambAttachment_s.pdf FL15058_R7_II_Z4-14-61317..pdf Verified By: John E. Scates, P.E. FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL15058_R7_AE_FL15058 Eval_Rept_cpan_s.pdf Created by Independent Third Party: Yes |
|
|
| 15058.8 |
15058.08 Rib Doors, Commercial |
Sectional steel doors with or without vinyl back or steel back polystyrene insulation and with an option for aluminum framed full view sections, for widths 8'-02" through 20'-02" see drawing for applicable pressures. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: Sectional doors provided for wind load applications. |
Installation Instructions FL15058_R7_II_BackJambAttachment_s.pdf FL15058_R7_II_Z4-16-61317.pdf Verified By: John E. Scates, P.E. FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL15058_R7_AE_FL15058 Eval_Rept_cpan_s.pdf Created by Independent Third Party: Yes |
|
|
| 15058.9 |
15058.09 Rib Doors, Commercial |
Sectional steel doors with or without vinyl back or steel back polystyrene insulation and with an option for aluminum framed full view sections, for widths 12'-02" through 16'-06" see drawing for applicable pressures. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: Sectional doors provided for wind load applications. |
Installation Instructions FL15058_R7_II_BackJambAttachment_s.pdf FL15058_R7_II_Z9-16-61317.pdf Verified By: John E. Scates, P.E. FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL15058_R7_AE_FL15058 Eval_Rept_cpan_s.pdf Created by Independent Third Party: Yes |
|
|
| 15058.10 |
15058.10 Rib Doors, Commercial |
Sectional steel doors with or without vinyl back or steel back polystyrene insulation and with an option for aluminum framed full view sections, for widths 12'-02" through 24'-02" see drawing for applicable pressures. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: Sectional doors provided for wind load applications. |
Installation Instructions FL15058_R7_II_BackJambAttachment_s.pdf FL15058_R7_II_Z5-18-61317.pdf Verified By: John E. Scates, P.E. FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL15058_R7_AE_FL15058 Eval_Rept_cpan_s.pdf Created by Independent Third Party: Yes |
|
|
| 15058.11 |
15058.11 Rib Doors, Commercial |
Sectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 16'-02" through 24'-02" see drawing for applicable pressures.
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Sectional doors provided for wind load and impact applications. |
Installation Instructions FL15058_R7_II_BackJambAttachment_s.pdf FL15058_R7_II_Z7i-18-61517.pdf Verified By: John E. Scates, P.E. FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL15058_R7_AE_FL15058 Eval_Rept_cpan_s.pdf Created by Independent Third Party: Yes |
|
|
| 15058.12 |
15058.12 Rib Doors, Commercial |
Sectional steel doors with or without vinyl back or steel back polystyrene insulation and with an option for aluminum framed full view sections, for widths 16'-08" through 28'-02" see drawing for applicable pressures. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: Sectional doors provided for wind load
applications. |
Installation Instructions FL15058_R7_II_BackJambAttachment_s.pdf FL15058_R7_II_Z8-18-61317.pdf Verified By: John E. Scates, P.E. FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL15058_R7_AE_FL15058 Eval_Rept_cpan_s.pdf Created by Independent Third Party: Yes |
|
|
| 15058.13 |
15058.13 Rib Doors, Commercial |
Sectional steel clad sandwich with polystyrene or thermally broken polyurethane insulation, for widths 15'-02" through 20'-02" see drawing for applicable pressures.
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Sectional doors provided for wind load and impact applications. |
Installation Instructions FL15058_R7_II_BackJambAttachment_s.pdf FL15058_R7_II_Z8i-18-61517.pdf Verified By: John E. Scates, P.E. FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL15058_R7_AE_FL15058 Eval_Rept_cpan_s.pdf Created by Independent Third Party: Yes |
|
|
| 15058.14 |
15058.14 Rib Doors, Commercial |
Sectional steel doors with or without vinyl back or steel back polystyrene insulation and with an option for aluminum framed full view sections, for widths 14'-02" through 22'-02" see drawing for applicable pressures. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: Sectional doors provided for wind load applications. |
Installation Instructions FL15058_R7_II_BackJambAttachment_s.pdf FL15058_R7_II_Z3-20-61317.pdf Verified By: John E. Scates, P.E. FL-51737 Created by Independent Third Party: Yes Evaluation Reports FL15058_R7_AE_FL15058 Eval_Rept_cpan_s.pdf Created by Independent Third Party: Yes |