| 48397.1 |
001 W3-09 PAN-2F151: 73, 75, 76, 75L, 1500, 190, 76V, 94, 84A, 4F, 94V, 42B, 55S, 48B, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV |
Steel Pan (min. 25 ga.) Single-Car (up to 9’0” wide) WINDCODE® W3 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +20 PSF/-21 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC). |
Installation Instructions FL48397_R0_II_104677-Rev03.pdf FL48397_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE #91932 Created by Independent Third Party: No Evaluation Reports FL48397_R0_AE_CCER_260821-A-00.pdf Created by Independent Third Party: No |
|
|
| 48397.2 |
002 W3-16 PAN-2F153: 73, 75, 76, 75L, 1500, 190, 76V, 94, 84A, 4F, 94V, 42B, 55S, 48B |
Steel Pan (min. 25 ga.) Double-Car (9’2” to 16’0” wide) WINDCODE® W3 Garage Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +20 PSF/-21 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC). |
Installation Instructions FL48397_R0_II_101308-Rev16.pdf FL48397_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE #91932 Created by Independent Third Party: No Evaluation Reports FL48397_R0_AE_CCER_260821-A-00.pdf Created by Independent Third Party: No |
|
|
| 48397.3 |
003 W4-09 PAN-2F151: 73, 75, 76, 75L, 1500, 190, 76V, 94, 84A, 4F, 94V, 42B, 55S, 48B, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV |
Steel Pan (min. 25 ga.) Single-Car (up to 9’0” wide) WINDCODE® W4 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25 PSF/-32 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. |
Installation Instructions FL48397_R0_II_300159-B-Rev20.pdf FL48397_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE #91932 Created by Independent Third Party: No Evaluation Reports FL48397_R0_AE_CCER_260821-A-00.pdf Created by Independent Third Party: No |
|
|
| 48397.4 |
004 W4-09 PAN-2F151: 73, 75, 76, 75L, 1500, 190, 76V, 94, 84A, 4F, 94V, 42B, 55S, 48B, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV |
Steel Pan (min. 25 ga.) Single-Car (up to 9’0” wide) WINDCODE® W4 Garage Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +25 PSF/-32 PSF Other: Solid doors (no glazing) or doors with optional impact-resistant glazing are impact-resistant (large missile impact). |
Installation Instructions FL48397_R0_II_300159-A-Rev20.pdf FL48397_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE #91932 Created by Independent Third Party: No Evaluation Reports FL48397_R0_AE_CCER_260821-A-00.pdf Created by Independent Third Party: No |
|
|
| 48397.5 |
005 W4-16 PAN-2F153: 73, 75, 76, 75L, 1500, 190, 76V, 94, 84A, 4F, 94V, 42B, 55S, 48B, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV |
Steel Pan (min. 25 ga.) Double-Car (9’2” to 16’0” wide) WINDCODE® W4 Garage Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +24 PSF/-24.5 PSF Other: Solid doors (no glazing) or doors with optional impact-resistant glazing are impact-resistant (large missile impact). |
Installation Instructions FL48397_R0_II_101711-B-Rev19.pdf FL48397_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE #91932 Created by Independent Third Party: No Evaluation Reports FL48397_R0_AE_CCER_260821-A-00.pdf Created by Independent Third Party: No |
|
|
| 48397.6 |
006 W4-16 PAN-2F153: 73, 75, 76, 75L, 1500, 190, 76V, 94, 84A, 4F, 94V, 42B, 55S, 48B, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV |
Steel Pan (min. 25 ga.) Double-Car (9’2” to 16’0” wide) WINDCODE® W4 Garage Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +24 PSF/-24.5 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. |
Installation Instructions FL48397_R0_II_101711-A-Rev19.pdf FL48397_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE #91932 Created by Independent Third Party: No Evaluation Reports FL48397_R0_AE_CCER_260821-A-00.pdf Created by Independent Third Party: No |
|
|
| 48397.7 |
007 W4-18 PAN-2F153: 73, 75, 76, 75L, 1500, 190, 76V, 94, 84A, 4F, 94V, 42B, 55S, 48B, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV |
Steel Pan (min. 25 ga.) 16’2” to 18’2” wide WINDCODE® W4 Garage Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25 PSF/-27 PSF Other: Doors with standard glazing meet the wind load requirements of the building code but DO NOT meet the impact resistant requirement for windborne debris regions. |
Installation Instructions FL48397_R0_II_104946-B-Rev04.pdf FL48397_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE #91932 Created by Independent Third Party: No Evaluation Reports FL48397_R0_AE_CCER_260821-A-00.pdf Created by Independent Third Party: No |
|
|
| 48397.8 |
008 W4-18 PAN-2F153: 73, 75, 76, 75L, 1500, 190, 76V, 94, 84A, 4F, 94V, 42B, 55S, 48B, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV |
Steel Pan (min. 25 ga.) 16’2” to 18’2” wide WINDCODE® W4 Garage Door with Optional Impact-Resistant Lites |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +25 PSF/-27 PSF Other: Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact). |
Installation Instructions FL48397_R0_II_104946-A-Rev04.pdf FL48397_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE #91932 Created by Independent Third Party: No Evaluation Reports FL48397_R0_AE_CCER_260821-A-00.pdf Created by Independent Third Party: No |
|
|
| 48397.9 |
009 W5-09 PAN-2F151: 73, 75, 76, 75L, 1500, 190, 76V, 94, 84A, 4F, 94V, 42B, 55S, 48B, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV |
Steel Pan (min. 25 ga.) Single-Car (up to 9’0” wide) WINDCODE® W5 Garage Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30 PSF/-32 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. |
Installation Instructions FL48397_R0_II_102110-B-Rev20.pdf FL48397_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE #91932 Created by Independent Third Party: No Evaluation Reports FL48397_R0_AE_CCER_260821-A-00.pdf Created by Independent Third Party: No |
|
|
| 48397.10 |
010 W5-09 PAN-2F151: 73, 75, 76, 75L, 1500, 190, 76V, 94, 84A, 4F, 94V, 42B, 55S, 48B, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV |
Steel Pan (min. 25 ga.) Single-Car (up to 9’0” wide) WINDCODE® W5 Garage Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +30 PSF/-32 PSF Other: Solid doors (no glazing) or doors with optional impact-resistant glazing are impact-resistant (large missile impact). |
Installation Instructions FL48397_R0_II_102110-A-Rev20.pdf FL48397_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE #91932 Created by Independent Third Party: No Evaluation Reports FL48397_R0_AE_CCER_260821-A-00.pdf Created by Independent Third Party: No |
|
|
| 48397.11 |
011 W5-16 PAN-2F153: 73, 75, 76, 75L, 1500, 190, 76V, 94, 84A, 4F, 94V, 42B, 55S, 48B, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV |
Steel Pan (min. 25 ga.) Double-Car (9’2” to 16’0” wide) WINDCODE® W5 Garage Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30 PSF/-30 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. |
Installation Instructions FL48397_R0_II_101593-B-Rev18.pdf FL48397_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE #91932 Created by Independent Third Party: No Evaluation Reports FL48397_R0_AE_CCER_260821-A-00.pdf Created by Independent Third Party: No |
|
|
| 48397.12 |
012 W5-16 PAN-2F153: 73, 75, 76, 75L, 1500, 190, 76V, 94, 84A, 4F, 94V, 42B, 55S, 48B, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV |
Steel Pan (min. 25 ga.) Double-Car (9’2” to 16’0” wide) WINDCODE® W5 Garage Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +30 PSF/-30 PSF Other: Solid doors (no glazing) or doors with optional impact-resistant glazing are impact-resistant (large missile impact). |
Installation Instructions FL48397_R0_II_101593-A-Rev18.pdf FL48397_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE #91932 Created by Independent Third Party: No Evaluation Reports FL48397_R0_AE_CCER_260821-A-00.pdf Created by Independent Third Party: No |
|
|
| 48397.13 |
013 W5-16 PAN-2F153/6: 73, 75, 76, 75L, 1500, 190, 76V, 94, 84A, 4F, 94V, 42B, 55S, 48B, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV |
Steel Pan (min. 25 ga.) Double-Car (9’2” to 16’0” wide) WINDCODE® W5 Garage Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +28 PSF/-30.5 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. |
Installation Instructions FL48397_R0_II_104698-B-Rev03.pdf FL48397_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE #91932 Created by Independent Third Party: No Evaluation Reports FL48397_R0_AE_CCER_260821-A-00.pdf Created by Independent Third Party: No |
|
|
| 48397.14 |
014 W5-16 PAN-2F153/6: 73, 75, 76, 75L, 1500, 190, 76V, 94, 84A, 4F, 94V, 42B, 55S, 48B, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV |
Steel Pan (min. 25 ga.) Double-Car (9’2” to 16’0” wide) WINDCODE® W5 Garage Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +28 PSF/-30.5 PSF Other: Solid doors (no glazing) or doors with optional impact-resistant glazing are impact-resistant (large missile impact). |
Installation Instructions FL48397_R0_II_104698-A-Rev03.pdf FL48397_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE #91932 Created by Independent Third Party: No Evaluation Reports FL48397_R0_AE_CCER_260821-A-00.pdf Created by Independent Third Party: No |
|
|
| 48397.15 |
015 W5-16-HY PAN-2F153/6: 73, 75, 76, 75L, 1500, 190, 76V, 94, 84A, 4F, 94V, 42B, 55S, 48B, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV |
Steel Pan (min. 25 ga.) Double-Car (9’2” to 16’0” wide) WINDCODE® W5 Garage Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +32 PSF/-32 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. |
Installation Instructions FL48397_R0_II_101922-B-Rev18.pdf FL48397_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE #91932 Created by Independent Third Party: No Evaluation Reports FL48397_R0_AE_CCER_260821-A-00.pdf Created by Independent Third Party: No |
|
|
| 48397.16 |
016 W5-16-HY PAN-2F153/6: 73, 75, 76, 75L, 1500, 190, 76V, 94, 84A, 4F, 94V, 42B, 55S, 48B, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV |
Steel Pan (min. 25 ga.) Double-Car (9’2” to 16’0” wide) WINDCODE® W5 Garage Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +32 PSF/-32 PSF Other: Solid doors (no glazing) or doors with optional impact-resistant glazing are impact-resistant (large missile impact). |
Installation Instructions FL48397_R0_II_101922-A-Rev18.pdf FL48397_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PWE #91932 Created by Independent Third Party: No Evaluation Reports FL48397_R0_AE_CCER_260821-A-00.pdf Created by Independent Third Party: No |
|
|
| 48397.17 |
017 W5-20 PAN-2F143: 94, 84A, 4F, 48B |
Steel Pan (min. 24 ga.) Double-Car (16’2” to 20’2” wide) WINDCODE® W5 Garage Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30 PSF/-32 PSF Other: Doors with standard glazing meet the wind load requirements of the building code but DO NOT meet the impact resistant requirement for windborne debris regions. |
Installation Instructions FL48397_R0_II_105101-Rev04.pdf FL48397_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE #91932 Created by Independent Third Party: No Evaluation Reports FL48397_R0_AE_105101-Rev04.pdf Created by Independent Third Party: No |
|
|
| 48397.18 |
018 W6-09 PAN-2F153: 73, 75, 76, 75L, 1500, 190, 76V, 94, 84A, 4F, 94V, 42B, 55S, 48B, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV |
Steel Pan (min. 25 ga.) Single-Car (up to 9’0” wide) WINDCODE® W6 Garage Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +38 PSF/-44 PSF Other: Doors with standard glazing meet the wind load requirements of the building code but DO NOT meet the impact resistant requirement for windborne debris regions. |
Installation Instructions FL48397_R0_II_101348-B-Rev21.pdf FL48397_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE #91932 Created by Independent Third Party: No Evaluation Reports FL48397_R0_AE_CCER_260821-A-00.pdf Created by Independent Third Party: No |
|
|
| 48397.19 |
019 W6-09 PAN-2F153: 73, 75, 76, 75L, 1500, 190, 76V, 94, 84A, 4F, 94V, 42B, 55S, 48B, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV |
Steel Pan (min. 25 ga.) Single-Car (up to 9’0” wide) WINDCODE® W6 Garage Door with Optional Impact-Resistant Lites |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +38 PSF/-44 PSF Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact). |
Installation Instructions FL48397_R0_II_101348-A-Rev21.pdf FL48397_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE #91932 Created by Independent Third Party: No Evaluation Reports FL48397_R0_AE_CCER_260821-A-00.pdf Created by Independent Third Party: No |
|
|
| 48397.20 |
020 W6-16 PAN-2F153: 73, 75, 76, 75L, 1500, 190, 76V, 94, 84A, 4F, 94V, 42B, 55S, 48B, GD5S, GD5SV, GR5S, GR5SV, AR5S, AR5SV, ED5S, ED5SV |
Steel Pan (min. 25 ga.) Double-Car (9’2” to 16’2” wide) WINDCODE® W6 Garage Door |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +36 PSF/-42 PSF Other: The standard glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. |
Installation Instructions FL48397_R0_II_104710-B-Rev05.pdf FL48397_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE #91932 Created by Independent Third Party: No Evaluation Reports FL48397_R0_AE_CCER_260821-A-00.pdf Created by Independent Third Party: No |
|