| 48387.1 |
002 W4-10 C-DSIU-1D477: 3717, 3718, 3720, 3722, 3724, 3730, EX3717, EX3717L, EX3717N, EX3718, EX3718L, EX3718N, EX3720, EX3720L, EX3720N, EX3722, EX3722L, EX3722N, EX3724, EX3724L, EX3724N, C7X17, C7X18, C7X20, C0X22, C7X24, 240U |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, up to 10’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25/-25 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL48387_R0_II_104040-Rev05.pdf FL48387_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL48387_R0_AE_CCER_260815-A-00.pdf Created by Independent Third Party: No |
|
|
| 48387.2 |
003 W4-14 C-DSIU-1D477: 3717, 3718, 3720, 3722, 3724, 3730, EX3717, EX3717L, EX3717N, EX3718, EX3718L, EX3718N, EX3720, EX3720L, EX3720N, EX3722, EX3722L, EX3722N, EX3724, EX3724L, EX3724N, C7X17, C7X18, C7X20, C0X22, C7X24, 240U |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, up to 14’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25/-25 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL48387_R0_II_104956-Rev05.pdf FL48387_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL48387_R0_AE_CCER_260815-A-00.pdf Created by Independent Third Party: No |
|
|
| 48387.3 |
004 W4-20 C-DSIU-1D477: 3717, 3718, 3720, 3722, 3724, 3730, C7X17, C7X18, C7X20, C0X22, C7X24, 240U |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, up to 20’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25/-28 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL48387_R0_II_105087-Rev03.pdf FL48387_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL48387_R0_AE_CCER_260815-A-00.pdf Created by Independent Third Party: No |
|
|
| 48387.4 |
005 W4-24 C-DSIU-1D477: 3717, 3718, 3720, 3722, 3724, 3730, C7X17, C7X18, C7X20, C0X22, C7X24, 240U |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, up to 24’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25/-25 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL48387_R0_II_105225-Rev04.pdf FL48387_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL48387_R0_AE_CCER_260815-A-00.pdf Created by Independent Third Party: No |
|
|
| 48387.5 |
006 W5-14 C-DSIU-1D477: 3717, 3718, 3720, 3722, 3724, 3730, EX3717, EX3717L, EX3717N, EX3718, EX3718L, EX3718N, EX3720, EX3720L, EX3720N, EX3722, EX3722L, EX3722N, EX3724, EX3724L, EX3724N, C7X17, C7X18, C7X20, C0X22, C7X24, 240U |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W5 Sectional Door, up to 14’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-34 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL48387_R0_II_104044-Rev06.pdf FL48387_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL48387_R0_AE_CCER_260815-A-00.pdf Created by Independent Third Party: No |
|
|
| 48387.6 |
007 W5-22 C-DSIU-1D477: 3717, 3718, 3720, 3722, 3724, 3730, C7X17, C7X18, C7X20, C0X22, C7X24, 240U |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W5 Sectional Door, up to 22’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +30/-30 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL48387_R0_II_105073-Rev04.pdf FL48387_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL48387_R0_AE_CCER_260815-A-00.pdf Created by Independent Third Party: No |
|
|
| 48387.7 |
008 W6-10 C-DSIU-1D477: 3717, 3718, 3720, 3722, 3724, 3730, C7X17, C7X18, C7X20, C0X22, C7X24, 240U |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W6 Sectional Door, up to 10’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +37/-44 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL48387_R0_II_104039-B-Rev08.pdf FL48387_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL48387_R0_AE_CCER_260815-A-00.pdf Created by Independent Third Party: No |
|
|
| 48387.8 |
009 W6-10 C-DSIU-1D477: 3717, 3718, 3720, 3722, 3724, 3730, C7X17, C7X18, C7X20, C0X22, C7X24, 240U |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W6 Sectional Door, up to 10’2” wide with Optional Impact-Resistant Lites
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +37/-44 Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
|
Installation Instructions FL48387_R0_II_104039-A-Rev08.pdf FL48387_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL48387_R0_AE_CCER_260815-A-00.pdf Created by Independent Third Party: No |
|
|
| 48387.9 |
010 W6-14 C-DSIU-1D477: 3717, 3718, 3720, 3722, 3724, 3730, C7X17, C7X18, C7X20, C0X22, C7X24, 240U |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W6 Sectional Door, up to 14’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +36/-40 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL48387_R0_II_104861-B-Rev03.pdf FL48387_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL48387_R0_AE_CCER_260815-A-00.pdf Created by Independent Third Party: No |
|
|
| 48387.10 |
011 W6-14 C-DSIU-1D477: 3717, 3718, 3720, 3722, 3724, 3730, C7X17, C7X18, C7X20, C0X22, C7X24, 240U |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W6 Sectional Door, up to 14’2” wide with Optional Impact-Resistant Lites
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +36/-40 Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
|
Installation Instructions FL48387_R0_II_104861-A-Rev03.pdf FL48387_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL48387_R0_AE_CCER_260815-A-00.pdf Created by Independent Third Party: No |
|
|
| 48387.11 |
012 W6-16 C-DSIU-1D477: 3717, 3718, 3720, 3722, 3724, 3730, C7X17, C7X18, C7X20, C0X22, C7X24, 240U |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W6 Sectional Door, up to 16’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +37/-42 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL48387_R0_II_104801-B-Rev05.pdf FL48387_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL48387_R0_AE_CCER_260815-A-00.pdf Created by Independent Third Party: No |
|
|
| 48387.12 |
013 W6-16 C-DSIU-1D477: 3717, 3718, 3720, 3722, 3724, 3730, C7X17, C7X18, C7X20, C0X22, C7X24, 240U |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W6 Sectional Door, up to 16’2” wide with Optional Impact-Resistant Lites
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +37/-42 Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
|
Installation Instructions FL48387_R0_II_104801-A-Rev05.pdf FL48387_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL48387_R0_AE_CCER_260815-A-00.pdf Created by Independent Third Party: No |
|
|
| 48387.13 |
014 W6-18 C-DSIU-1D477: 3717, 3718, 3720, 3722, 3724, 3730, C7X17, C7X18, C7X20, C0X22, C7X24, 240U |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W6 Sectional Door, up to 18’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +36/-40 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL48387_R0_II_104826-B-Rev04.pdf FL48387_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL48387_R0_AE_CCER_260815-A-00.pdf Created by Independent Third Party: No |
|
|
| 48387.14 |
015 W6-18 C-DSIU-1D477: 3717, 3718, 3720, 3722, 3724, 3730, C7X17, C7X18, C7X20, C0X22, C7X24, 240U |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W6 Sectional Door, up to 18’2” wide with Optional Impact-Resistant Lites
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +36/-40 Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
|
Installation Instructions FL48387_R0_II_104826-A-Rev04.pdf FL48387_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL48387_R0_AE_CCER_260815-A-00.pdf Created by Independent Third Party: No |
|
|
| 48387.15 |
016 W8-12 C-DSIU-1D477: 3717, C7X17, 3718, C7X18, 3720, C7X20, 240U, 3722, C0X22, 3724, C7X24, 244U, 3730 |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W8 Sectional Door, up to 12’2” wide with Optional Impact-Resistant Lites
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +52/-58 Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
|
Installation Instructions FL48387_R0_II_104815-Rev06 unsigned.pdf FL48387_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL48387_R0_AE_CCER_260815-A-00.pdf Created by Independent Third Party: No |
|
|
| 48387.16 |
017 W8-14 C-DSIU-1D477: 3717, C7X17, 3718, C7X18, 3720, C7X20, 240U, 3722, C0X22, 3724, C7X24, 244U, 3730 |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W8 Sectional Door, up to 14’2” wide with Optional Impact-Resistant Lites
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +52/-58 Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
|
Installation Instructions FL48387_R0_II_104842-Rev07.pdf FL48387_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL48387_R0_AE_CCER_260815-A-00.pdf Created by Independent Third Party: No |
|
|
| 48387.17 |
018 W8-16 C-DSIU-1F477: 3720, C7X20, 240U, 3722, C0X22, 3724, C7X24, 244U, 3730 |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W8 Sectional Door, up to 16’2” wide with Optional Impact-Resistant Lites
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-58 Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact).
|
Installation Instructions FL48387_R0_II_104900-Rev04.pdf FL48387_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL48387_R0_AE_CCER_260815-A-00.pdf Created by Independent Third Party: No |
|
|
| 48387.18 |
Test001 W4-09 C-DSIU-1D477: 3717, 3718, 3720, 3722, 3724, 3730, EX3717, EX3717L, EX3717N, EX3718, EX3718L, EX3718N, EX3720, EX3720L, EX3720N, EX3722, EX3722L, EX3722N, EX3724, EX3724L, EX3724N, C7X17, C7X18, C7X20, C0X22, C7X24, 240U |
Double-skin Insulated Intellicore® (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, up to 9’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +25/-25 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC).
|
Installation Instructions FL48387_R0_II_104993-Rev05.pdf FL48387_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL48387_R0_AE_CCER_260815-A-00.pdf FL48387_R0_AE_Statement_on_Equivalency - E1886 - JDW 260814.pdf Created by Independent Third Party: No |