| 32360.1 |
Models 5120, 9100, 9405, 9605, TS100, TS120 |
9'-0" Max width. 12'-0" Max height. Glazing available in 3rd section or higher. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +12.70/-14.40 Other: Non-impact resistant glazing does not meet the requirements for the wind-borne debris regions. Impact resistant glazing available, though door is not impact rated.
|
Installation Instructions FL32360_R4_II_411625_0640_rA_s.pdf FL32360_R4_II_WD-JambConnectionSupplement_RevB_sFL.pdf Verified By: John Scates 51737 Created by Independent Third Party: Yes Evaluation Reports FL32360_R4_AE_Eval_Rept_9100_s.pdf Created by Independent Third Party: Yes |
|
|
| 32360.2 |
Models 5120, 9100, 9405, 9605, TS100, TS120 |
9'-0" Max width. 12'-0" Max height. Glazing available in 3rd section or higher.
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +15.4/-17.4 Other: Non-impact resistant glazing does not meet the requirements for the wind-borne debris regions. Impact resistant glazing available, though door is not impact rated. |
Installation Instructions FL32360_R4_II_411626_0641_rA_s.pdf FL32360_R4_II_WD-JambConnectionSupplement_RevB_sFL.pdf Verified By: John Scate 51737 Created by Independent Third Party: Yes Evaluation Reports FL32360_R4_AE_Eval_Rept_9100_s.pdf Created by Independent Third Party: Yes |
|
|
| 32360.3 |
Models 5120, 9100, 9405, 9605, TS100, TS120 |
9'-0" Max width. 12'-0" Max height. Glazing available in 3rd section or higher.
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +18.4/-20.8 Other: Non-impact resistant glazing does not meet the requirements for the wind-borne debris regions. Impact resistant glazing available, though door is not impact rated. |
Installation Instructions FL32360_R4_II_411627_0642_rA_s.pdf FL32360_R4_II_WD-JambConnectionSupplement_RevB_sFL.pdf Verified By: John Scates 51737 Created by Independent Third Party: Yes Evaluation Reports FL32360_R4_AE_Eval_Rept_9100_s.pdf Created by Independent Third Party: Yes |
|
|
| 32360.4 |
Models 5120, 9100, 9405, 9605, TS100, TS120 |
9'-0" Max width. 12'-0" Max height. Glazing available in 3rd section or higher. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +25/-28.2 Other: Non-impact resistant glazing does not meet the requirements for the wind-borne debris regions. Impact resistant glazing meets the requirements for the wind-borne debris regions.
|
Installation Instructions FL32360_R4_II_411628_0643_rA_s.pdf FL32360_R4_II_WD-JambConnectionSupplement_RevB_sFL.pdf Verified By: John Scates 51737 Created by Independent Third Party: Yes Evaluation Reports FL32360_R4_AE_Eval_Rept_9100_s.pdf Created by Independent Third Party: Yes |
|
|
| 32360.5 |
Models 5120, 9100, 9405, 9605, TS100, TS120 |
9'-0" Max width. 12'-0" Max height. Glazing available in 3rd section or higher.
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +32.6/-36.9 Other: Non-impact resistant glazing does not meet the requirements for the wind-borne debris regions. Impact resistant glazing meets the requirements for the wind-borne debris regions. |
Installation Instructions FL32360_R4_II_411629_0644_rA_s.pdf FL32360_R4_II_WD-JambConnectionSupplement_RevB_sFL.pdf Verified By: John Scates 51737 Created by Independent Third Party: Yes Evaluation Reports FL32360_R4_AE_Eval_Rept_9100_s.pdf Created by Independent Third Party: Yes |
|
|
| 32360.6 |
Models 5120, 9100, 9405, 9605, TS100, TS120 |
9'-0" Max width. 12'-0" Max height. Glazing available in top section only. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +41.3/-46.7 Other: Non-impact resistant glazing does not meet the requirements for the wind-borne debris regions. Impact resistant glazing meets the requirements for the wind-borne debris regions. |
Installation Instructions FL32360_R4_II_411630_0645_rA_s.pdf FL32360_R4_II_WD-JambConnectionSupplement_RevB_sFL.pdf Verified By: John Scates 51737 Created by Independent Third Party: Yes Evaluation Reports FL32360_R4_AE_Eval_Rept_9100_s.pdf Created by Independent Third Party: Yes |
|
|
| 32360.7 |
Models 5120, 9100, 9405, 9605, TS100, TS120 |
16'-0" Max width. 12'-0" Max height. Glazing available in 3rd section or higher. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +12.7/-14.4 Other: Non-impact resistant glazing does not meet the requirements for the wind-borne debris regions. Impact resistant glazing available, though door is not impact rated. |
Installation Instructions FL32360_R4_II_411633_0647_rA_s.pdf FL32360_R4_II_WD-JambConnectionSupplement_RevB_sFL.pdf Verified By: John Scates 51737 Created by Independent Third Party: Yes Evaluation Reports FL32360_R4_AE_Eval_Rept_9100_s.pdf Created by Independent Third Party: Yes |
|
|
| 32360.8 |
Models 5120, 9100, 9405, 9605, TS100, TS120 |
16'-0" Max width. 12'-0" Max height. Glazing available in 3rd section or higher.
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +15.4/-17.4 Other: Non-impact resistant glazing does not meet the requirements for the wind-borne debris regions. Impact resistant glazing available, though door is not impact rated.
|
Installation Instructions FL32360_R4_II_411634_0648_rA_s.pdf FL32360_R4_II_WD-JambConnectionSupplement_RevB_sFL.pdf Verified By: John Scates 51737 Created by Independent Third Party: Yes Evaluation Reports FL32360_R4_AE_Eval_Rept_9100_s.pdf Created by Independent Third Party: Yes |
|
|
| 32360.9 |
Models 5120, 9100, 9405, 9605, TS100, TS120 |
16'-0" Max width. 12'-0" Max height. Glazing available in 3rd section or higher.
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +18.4/-20.8 Other: Non-impact resistant glazing does not meet the requirements for the wind-borne debris regions. Impact resistant glazing available, though door is not impact rated.
|
Installation Instructions FL32360_R4_II_411635_0649_rA_s.pdf FL32360_R4_II_WD-JambConnectionSupplement_RevB_sFL.pdf Verified By: John Scates 51737 Created by Independent Third Party: Yes Evaluation Reports FL32360_R4_AE_Eval_Rept_9100_s.pdf Created by Independent Third Party: Yes |
|
|
| 32360.10 |
Models 5120, 9100, 9405, 9605, TS100, TS120 |
16'-0" Max width. 12'-0" Max height. Glazing available in 3rd section or higher. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +23/-25 Other: Non-impact resistant glazing does not meet the requirements for the wind-borne debris regions. Impact resistant glazing available, though door is not impact rated. |
Installation Instructions FL32360_R4_II_411636_0650_rA_s.pdf FL32360_R4_II_WD-JambConnectionSupplement_RevB_sFL.pdf Verified By: John Scates 51737 Created by Independent Third Party: Yes Evaluation Reports FL32360_R4_AE_Eval_Rept_9100_s.pdf Created by Independent Third Party: Yes |
|
|
| 32360.11 |
Models 5120, 9100, 9405, 9605, TS100, TS120 |
16'-0" Max width. 12'-0" Max height. Glazing available in 3rd section or higher.
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +25/-28.2 Other: Non-impact resistant glazing does not meet the requirements for the wind-borne debris regions. Impact resistant glazing meets the requirements for the wind-borne debris regions.
|
Installation Instructions FL32360_R4_II_411637_0651_rA_s.pdf FL32360_R4_II_WD-JambConnectionSupplement_RevB_sFL.pdf Verified By: John Scates 51737 Created by Independent Third Party: Yes Evaluation Reports FL32360_R4_AE_Eval_Rept_9100_s.pdf Created by Independent Third Party: Yes |
|
|
| 32360.12 |
Models 5120, 9100, 9405, 9605, TS100, TS120 |
16'-0" Max width. 12'-0" Max height. Glazing available in 3rd section or higher.
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +28.7/-32.4 Other: Non-impact resistant glazing does not meet the requirements for the wind-borne debris regions. Impact resistant glazing meets the requirements for the wind-borne debris regions.
|
Installation Instructions FL32360_R4_II_411638_0652_rA_s.pdf FL32360_R4_II_WD-JambConnectionSupplement_RevB_sFL.pdf Verified By: John Scates 51737 Created by Independent Third Party: Yes Evaluation Reports FL32360_R4_AE_Eval_Rept_9100_s.pdf Created by Independent Third Party: Yes |
|
|
| 32360.13 |
Models 5120, 9100, 9405, 9605, TS100, TS120 |
16'-0" Max width. 12'-0" Max height. Glazing available in top section only. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +32.6/-36.9 Other: Glazing is impact-resistant and meets the requirements for the wind-borne debris regions.
|
Installation Instructions FL32360_R4_II_411639_0653_rA_s.pdf FL32360_R4_II_WD-JambConnectionSupplement_RevB_sFL.pdf Verified By: John Scates 51737 Created by Independent Third Party: Yes Evaluation Reports FL32360_R4_AE_Eval_Rept_9100_s.pdf Created by Independent Third Party: Yes |
|
|
| 32360.14 |
Models 5120, 9100, 9405, 9605, TS100, TS120 |
16'-0" Max width. 12'-0" Max height. Glazing available in top section only.
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +41.3/-46.7 Other: Glazing is impact-resistant and meets the requirements for the wind-borne debris regions. |
Installation Instructions FL32360_R4_II_411640_0654_rA_s.pdf FL32360_R4_II_WD-JambConnectionSupplement_RevB_sFL.pdf Verified By: John Scates 51737 Created by Independent Third Party: Yes Evaluation Reports FL32360_R4_AE_Eval_Rept_9100_s.pdf Created by Independent Third Party: Yes |
|
|
| 32360.15 |
Models 5120, 9100, 9405, 9605, TS100, TS120 |
9'-0" Max width. 12'-0" Max height. Glazing available in top section only.
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +46/-52 Other: Glazing is impact-resistant and meets the requirements for the wind-borne debris regions.
|
Installation Instructions FL32360_R4_II_411632_0646_rA_s.pdf FL32360_R4_II_WD-JambConnectionSupplement_RevB_sFL.pdf Verified By: John Scates 51737 Created by Independent Third Party: Yes Evaluation Reports FL32360_R4_AE_Eval_Rept_9100_s.pdf Created by Independent Third Party: Yes |
|
|
| 32360.16 |
Models 5120, 9100, 9405, 9605, TS100, TS120 |
18'-0" Max width. 12'-0" Max height. Glazing available in 3rd section or higher. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +12.7/-14.4 Other: Non-impact resistant glazing does not meet the requirements for the wind-borne debris regions. Impact resistant glazing available, though door is not impact rated. |
Installation Instructions FL32360_R4_II_411641_0655_r-_s.pdf FL32360_R4_II_WD-JambConnectionSupplement_RevB_sFL.pdf Verified By: John Scates 51737 Created by Independent Third Party: Yes Evaluation Reports FL32360_R4_AE_Eval_Rept_9100_s.pdf Created by Independent Third Party: Yes |
|
|
| 32360.17 |
Models 5120, 9100, 9405, 9605, TS100, TS120 |
18'-0" Max width. 12'-0" Max height. Glazing available in 3rd section or higher. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +18.4/-20.8 Other: Non-impact resistant glazing does not meet the requirements for the wind-borne debris regions. Impact resistant glazing available, though door is not impact rated. |
Installation Instructions FL32360_R4_II_411642_0656_ r-_s.pdf FL32360_R4_II_WD-JambConnectionSupplement_RevB_sFL.pdf Verified By: John Scates 51737 Created by Independent Third Party: Yes Evaluation Reports FL32360_R4_AE_Eval_Rept_9100_s.pdf Created by Independent Third Party: Yes |
|
|
| 32360.18 |
Models 5120, 9100, 9405, 9605, TS100, TS120 |
18'-0" Max width. 12'-0" Max height. Glazing available in 3rd section or higher. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +25.0/-28.2 Other: Glazing is impact-resistant and meets the requirements for the wind-borne debris regions. |
Installation Instructions FL32360_R4_II_411643_0657_r-_s.pdf FL32360_R4_II_WD-JambConnectionSupplement_RevB_sFL.pdf Verified By: John Scates 51737 Created by Independent Third Party: Yes Evaluation Reports FL32360_R4_AE_Eval_Rept_9100_s.pdf Created by Independent Third Party: Yes |
|
|
| 32360.19 |
Models 5120, 9100, 9405, 9605, TS100, TS120 |
18'-0" Max width. 12'-0" Max height. Glazing available in top section only. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +32.6/-36.9 Other: Glazing is impact-resistant and meets the requirements for the wind-borne debris regions. |
Installation Instructions FL32360_R4_II_411644_0658_r-s.pdf FL32360_R4_II_WD-JambConnectionSupplement_RevB_sFL.pdf Verified By: John Scates 51737 Created by Independent Third Party: Yes Evaluation Reports FL32360_R4_AE_Eval_Rept_9100_s.pdf Created by Independent Third Party: Yes |
|
|
| 32360.20 |
Models 5120, 9100, 9405, 9605, TS100, TS120 |
18'-0" Max width. 12'-0" Max height. Glazing available in top section only. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +41.3/-46.7 Other: Glazing is impact-resistant and meets the requirements for the wind-borne debris regions. |
Installation Instructions FL32360_R4_II_411645_0659_r-_s.pdf FL32360_R4_II_WD-JambConnectionSupplement_RevB_sFL.pdf Verified By: John Scates 51737 Created by Independent Third Party: Yes Evaluation Reports FL32360_R4_AE_Eval_Rept_9100_s.pdf Created by Independent Third Party: Yes |