| 30895.1 |
E+ ALUMINUM BI-FOLD INSWING IMPACT HVHZ |
E+ ALUMINUM BI-FOLD INSWING IMPACT HVHZ |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: REFER TO INSTALLATION INSTRUCTIONS FOR DESIGN PRESSURE RATINGS. GLASS INTERLAYER COMPLIES WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE FOR KURARAY INTERLAYERS. |
Installation Instructions FL30895_R3_II_08-03693.pdf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL30895_R3_AE_514830.pdf Created by Independent Third Party: Yes |
|
|
| 30895.2 |
E+ ALUMINUM BI-FOLD INSWING NON-IMPACT HVHZ |
E+ ALUMINUM BI-FOLD INSWING NON-IMPACT HVHZ |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: REFER TO INSTALLATION INSTRUCTIONS FOR DESIGN PRESSURE RATINGS. |
Installation Instructions FL30895_R3_II_08-03694.pdf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL30895_R3_AE_514831.pdf Created by Independent Third Party: Yes |
|
|
| 30895.3 |
E+ ALUMINUM BI-FOLD OUTSWING IMPACT HVHZ |
E+ ALUMINUM BI-FOLD OUTSWING DOOR, IMPACT HVHZ |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: REFER TO INSTALLATION INSTRUCTIONS FOR DESIGN PRESSURE RATINGS. GLASS INTERLAYER COMPLIES WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE FOR KURARAY INTERLAYERS. |
Installation Instructions FL30895_R3_II_08-03529A.pdf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL30895_R3_AE_514593A.pdf Created by Independent Third Party: Yes |
|
|
| 30895.4 |
E+ ALUMINUM BI-FOLD OUTSWING NON-IMPACT HVHZ |
E+ ALUMINUM BI-FOLD OUTSWING DOOR, NON-IMPACT HVHZ |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: REFER TO INSTALLATION INSTRUCTIONS FOR DESIGN PRESSURE RATINGS. |
Installation Instructions FL30895_R3_II_08-03620.pdf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL30895_R3_AE_514726.pdf Created by Independent Third Party: Yes |
|
|
| 30895.5 |
E3 HURRICANE INSWING IMPACT |
SERIES E3 HURRICANE INSWING ALUMINUM BI-FOLD DOOR, IMPACT NON-HVHZ |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: REFER TO INSTALLATION INSTRUCTIONS FOR DESIGN PRESSURE RATINGS. |
Installation Instructions FL30895_R3_II_08-03505A.pdf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL30895_R3_AE_514554A.pdf Created by Independent Third Party: Yes |
|
|
| 30895.6 |
E3 HURRICANE INSWING IMPACT HVHZ |
SERIES E3 HURRICANE INSWING ALUMINUM BI-FOLD DOOR, IMPACT HVHZ |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: REFER TO INSTALLATION INSTRUCTIONS FOR DESIGN PRESSURE RATINGS. GLASS INTERLAYER COMPLIES WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE FOR KURARAY INTERLAYERS. |
Installation Instructions FL30895_R3_II_08-03493A.pdf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL30895_R3_AE_514534A.pdf Created by Independent Third Party: Yes |
|
|
| 30895.7 |
E3 HURRICANE INSWING NON-IMPACT HVHZ |
SERIES E3 HURRICANE INSWING ALUMINUM BI-FOLD DOOR, NON-IMPACT HVHZ |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: REFER TO INSTALLATION INSTRUCTIONS FOR DESIGN PRESSURE RATINGS |
Installation Instructions FL30895_R3_II_08-03611.pdf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL30895_R3_AE_514706.pdf Created by Independent Third Party: Yes |
|
|
| 30895.8 |
E3 HURRICANE OUTSWING IMPACT |
SERIES E3 HURRICANE OUTSWING ALUMINUM BI-FOLD DOOR, IMPACT NON-HVHZ |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: REFER TO INSTALLATION INSTRUCTIONS FOR DESIGN PRESSURE RATINGS. |
Installation Instructions FL30895_R3_II_08-03504A.pdf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL30895_R3_AE_514553A.pdf Created by Independent Third Party: Yes |
|
|
| 30895.9 |
E3 HURRICANE OUTSWING IMPACT HVHZ |
SERIES E3 HURRICANE OUTSWING ALUMINUM BI-FOLD DOOR, IMPACT HVHZ |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: REFER TO INSTALLATION INSTRUCTIONS FOR DESIGN PRESSURE RATINGS. GLASS INTERLAYER COMPLIES WITH THE REQUIREMENTS OF THE FLORIDA BUILDING CODE ACCORDING TO MIAMI-DADE FOR KURARAY INTERLAYERS. |
Installation Instructions FL30895_R3_II_08-03492A.pdf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL30895_R3_AE_514533A.pdf Created by Independent Third Party: Yes |
|
|
| 30895.10 |
E3 HURRICANE OUTSWING NON-IMPACT HVHZ |
SERIES E3 HURRICANE OUTSWING ALUMINUM BI-FOLD DOOR, NON-IMPACT HVHZ |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: REFER TO INSTALLATION INSTRUCTIONS FOR DESIGN PRESSURE RATINGS. |
Installation Instructions FL30895_R3_II_08-03612.pdf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL30895_R3_AE_514707.pdf Created by Independent Third Party: Yes |
|
|
| 30895.11 |
E3 INSWING NON-IMPACT |
SERIES E3 INSWING ALUMINUM BI-FOLD DOOR, NON-IMPACT |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: REFER TO INSTALLATION INSTRUCTIONS FOR DESIGN PRESSURE RATINGS. |
Installation Instructions FL30895_R3_II_08-04007.pdf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL30895_R3_AE_515316.pdf Created by Independent Third Party: Yes |
|
|
| 30895.12 |
E3 OUTSWING NON-IMPACT |
SERIES E3 OUTSWING ALUMINUM BI-FOLD DOOR, NON-IMPACT |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: REFER TO INSTALLATION INSTRUCTIONS FOR DESIGN PRESSURE RATINGS. |
Installation Instructions FL30895_R3_II_08-03494A.pdf Verified By: Luis Roberto Lomas 62514 Created by Independent Third Party: Yes Evaluation Reports FL30895_R3_AE_514535A.pdf Created by Independent Third Party: Yes |