Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL5013-R10
Application Type Revision
Code Version 2020
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Roll-a-way by QMI
Address/Phone/Email 1661 Glenlake Avenue
Itasca, IL 60143
(727) 744-5332
dfowler@qmiusa.com
 
Authorized Signature Donald Fowler
dfowler@qmiusa.com
 
Technical Representative Donald Fowler
Address/Phone/Email 1661 Glenlake Avenue
Itasca, IL 60143
(630) 529-7111
dfowler@qmiusa.com
 
Quality Assurance Representative Jim Daluga
Address/Phone/Email 1661 Glenlake Avenue
Itasca, IL 60143
(630) 529-7111
jdaluga@qmiusa.com
 
Category Shutters
Subcategory Roll-up
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Donald Lynn Fowler
Florida License PE-0050458
Quality Assurance Entity National Accreditation and Management Institute
Quality Assurance Contract Expiration Date 12/31/2023
Validated By Jesus Gonzalez, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL5013_R10_COI_FL5013-R10.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E1886-122012
ASTM E1996-172017
ASTM E330-022002
TAS 201, 202, & 2031994
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL5013_R10_Equiv_FL5013-R10.pdf
 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 10/06/2020
Date Validated 11/03/2020
Date Pending FBC Approval 11/05/2020
Date Approved 12/15/2020
 
Summary of Products
FL # Model, Number or Name Description
5013.1 1138ER Roll-a-way by QMI 38mm extruded aluminum slat system with end retention screws and tracks.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: N/A
 Other: Not to be used in HVHZ. Span 156", +/-31 p.s.f., Max. span tested 144", Test p.s.f. +/-40, Large Missle "C" 9lb @ 50Ft/s. Weakest product tested to qualify the stronger with additional testing to verify span charts. All span limitations are performance only and may be limited further by choice of mounting configurations.
Installation Instructions
 FL5013_R10_II_FL5013-R10.pdf
 Verified By: Donald L. Fowler, P.E. 50458
 Created by Independent Third Party: No
Evaluation Reports
 FL5013_R10_AE_CTLA 2017W (US60ER,P55DER,1138ER,P55ER,P55TER, - P55ER2ND).pdf
 FL5013_R10_AE_FL 5013 FBC 2020 Eval Report.pdf
 FL5013_R10_AE_FL 5013-R3 Address Change Notice.pdf
 FL5013_R10_AE_HETI-99-830A B C (Removable Storm Bar).pdf
 PTID_5013_T_ATL Report No.0126.01-00.pdf
 PTID_5013_T_ATL Report No.0316.01-05.pdf
 PTID_5013_T_HTL Job No.0006-0106-03.pdf
 PTID_5013_T_HTL Job No.006-0224-03-11.pdf
 PTID_5013_T_HTL Job No.006-0224-03-9.pdf
 Created by Independent Third Party: No
5013.2 AL7-E Roll-a-way by QMI single wall extruded aluminum slat with end retention screws and rails.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +100/-100
 Other: Not to be used in the HVHZ. Span 233" +/- 35 p.s.f., maximum +/-100 p.s.f. at span 102". All span limitations are performance only and may be limited further by choice of mounting configurations.
Installation Instructions
 FL5013_R10_II_FL5013-R10.pdf
 Verified By: Donald L. Fowler 50458
 Created by Independent Third Party: No
Evaluation Reports
 FL5013_R10_AE_CTLA-201W-1 (AL7-E).pdf
 FL5013_R10_AE_FL 5013 FBC 2020 Eval Report.pdf
 FL5013_R10_AE_TensileTestCTL.pdf
 Created by Independent Third Party: No
5013.3 P55DER Roll-a-way by QMI 55mm extruded PVC slat and double extruded aluminum rebar system with end retention screws and tracks.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: N/A
 Other: Not to be used in HVHZ, minimum span 37". Span 164", +/-10 p.s.f., Max. span tested 144", Test p.s.f. +/-40, Large Missle "C" 9lb @ 50Ft/s. Weakest product tested to qualify the stronger with additional testing to verify span charts. 36" span tested to +/- 287 p.s.f.. All span limitations are performance only and may be limited further by choice of mounting configurations.
Installation Instructions
 FL5013_R10_II_FL5013-R10.pdf
 Verified By: Donald L. Fowler, P.E. 50458
 Created by Independent Third Party: No
Evaluation Reports
 FL5013_R10_AE_91850.01-401-44-R0.pdf
 FL5013_R10_AE_CTLA 2017W (US60ER,P55DER,1138ER,P55ER,P55TER, - P55ER2ND).pdf
 FL5013_R10_AE_FL 5013 FBC 2020 Eval Report.pdf
 FL5013_R10_AE_FL 5013-R3 PVC Certification.pdf
 FL5013_R10_AE_HTL006-0106-03 (P55DER).pdf
 Created by Independent Third Party: No
5013.4 P55ER Roll-a-way by QMI 55mm extruded PVC slat and extruded aluminum rebar system with end retention screws and tracks.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: N/A
 Other: Not to be used in HVHZ. Span 164", +/-10 p.s.f., Max. span tested 144", Test p.s.f. +/-40, Small Missle. Weakest product tested to qualify the stronger with additional testing to verify span charts. All span limitations are performance only and may be limited further by choice of mounting configurations.
Installation Instructions
 FL5013_R10_II_FL5013-R10.pdf
 Verified By: Donald L. Fowler, P.E. 50458
 Created by Independent Third Party: No
Evaluation Reports
 FL5013_R10_AE_CTLA 2017W (US60ER,P55DER,1138ER,P55ER,P55TER, - P55ER2ND).pdf
 FL5013_R10_AE_FL 5013 FBC 2020 Eval Report.pdf
 FL5013_R10_AE_FL 5013-R3 PVC Certification.pdf
 FL5013_R10_AE_HTL 006-0224-03-11 (P55ER - P55ER2ND).pdf
 Created by Independent Third Party: No
5013.5 P55ER 2nd Roll-a-way by QMI 55mm extruded PVC slat and extruded aluminum rebar system with end retention screws and tracks.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: N/A
 Other: Not to be used in HVHZ. Span 132", +/-17 p.s.f., Max. span tested 144", Test p.s.f. +/-40, Small Missle. Weakest product tested to qualify the stronger with additional testing to verify span charts. All span limitations are performance only and may be limited further by choice of mounting configurations.
Installation Instructions
 FL5013_R10_II_FL5013-R10.pdf
 Verified By: Donald L. Fowler, P.E. 50458
 Created by Independent Third Party: No
Evaluation Reports
 FL5013_R10_AE_CTLA 2017W (US60ER,P55DER,1138ER,P55ER,P55TER, - P55ER2ND).pdf
 FL5013_R10_AE_FL 5013 FBC 2020 Eval Report.pdf
 FL5013_R10_AE_FL 5013-R3 PVC Certification.pdf
 FL5013_R10_AE_HTL 006-0104-05 (P55TER-P55ER2nd 72PSF).pdf
 FL5013_R10_AE_HTL 006-0224-03-11 (P55ER - P55ER2ND).pdf
 FL5013_R10_AE_HTL 006-0224-03-9 (P55ER2ND).pdf
 Created by Independent Third Party: No
5013.6 P55TER Slat type Roll-a-way by QMI 55mm extruded PVC slat and extruded aluminum rebar system with end retention screws and tracks.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: N/A
 Other: Not to be used in HVHZ. Span 144", +/-40 p.s.f., Max. span tested 144", Large Missle "C" 9lb @ 50Ft/s. Weakest product tested to qualify the stronger with addional testing to verify span charts. All span limitations are performance only and may be limited further by choice of mounting configurations.
Installation Instructions
 FL5013_R10_II_FL5013-R10.pdf
 Verified By: Donald L. Fowler, P.E. 50458
 Created by Independent Third Party: No
Evaluation Reports
 FL5013_R10_AE_ATL 0316.01-05 (P55TER).pdf
 FL5013_R10_AE_CTLA 2017W (US60ER,P55DER,1138ER,P55ER,P55TER, - P55ER2ND).pdf
 FL5013_R10_AE_FL 5013 FBC 2020 Eval Report.pdf
 FL5013_R10_AE_FL 5013-R3 PVC Certification.pdf
 Created by Independent Third Party: No
5013.7 QOMPACT Roll-a-way by QMI extruded aluminum slats that cluster tightly with end retention screws and tracks.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +160/-160
 Other: Not to be used in the HVHZ. Span 236" +/- 40 p.s.f., maximum +/-160 p.s.f. at span 96". All span limitations are performance only and may be limited further by choice of mounting configurations.
Installation Instructions
 FL5013_R10_II_FL5013-R10.pdf
 Verified By: Donald L. Fowler, P.E. 50458
 Created by Independent Third Party: No
Evaluation Reports
 FL5013_R10_AE_FL 5013 FBC 2020 Eval Report.pdf
 FL5013_R10_AE_FTL Lab. Number 6869.pdf
 Created by Independent Third Party: Yes
5013.8 US60ER Roll-a-way by QMI 55mm double wall extruded aluminum slat with end retention screws and tracks.
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: N/A
 Other: Not to be used in HVHZ, unless equal to or less than 96" wide (span) x 96" high (+/- 100 PSF). Span 156", +/-31 p.s.f., Max. span tested 144", Test p.s.f. +/-40, Large Missle "C" 9lb @ 50Ft/s. Weakest product tested to qualify the stronger with additional testing to verify span charts. All span limitations are performance only and may be limited further by choice of mounting configurations.
Installation Instructions
 FL5013_R10_II_FL5013-R10.pdf
 Verified By: Donald L Fowler, P.E. 50458
 Created by Independent Third Party: No
Evaluation Reports
 FL5013_R10_AE_ATL 0126.01-00 (US60 garage door).pdf
 FL5013_R10_AE_CTLA 2017W (US60ER,P55DER,1138ER,P55ER,P55TER, - P55ER2ND).pdf
 FL5013_R10_AE_FL 5013 FBC 2020 Eval Report.pdf
 Created by Independent Third Party: No
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex