FL # FL47358-R0
Application Type New
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Elite Metal Manufacturing, LLC
Address/Phone/Email 10121 88th Trace
Live Oak, FL 32064
(386) 688-3627
kyle@lawyerkyle.com
 
Authorized Signature Kyle McLeod
kyle@lawyerkyle.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Panel Walls
Subcategory Siding
 
Compliance Method Test Report
 
Testing Lab Farabaugh Engineering and Testing, LLC
Quality Assurance Entity Farabaugh Engineering and Testing, LLC
Quality Assurance Contract Expiration Date 03/25/2031
Validated By Steven M. Urich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL47358_R0_COI_FL39466_R1_COI_FETCOIElite.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E3302014
 
Equivalence of Product Standards
Certified By

 
 
 
 
Product Approval Method Method 1 Option B
 
Date Submitted 02/24/2025
Date Validated 02/26/2025
Date Pending FBC Approval 02/27/2025
Date Approved 04/15/2025
Date Revised 10/20/2026
 
Summary of Products
FL # Model, Number or Name Description
47358.1 Elite Rib Wall Panel 29 ga Elite Rib Wall Panel Over Open Framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +48.53/-45.07
 Other: Per ASTM E330 tests over 14 ga open framing supports located at 4' on centers with Safety Factor of 1.5
Installation Instructions
 FL47358_R0_II_T295-24-Elite.pdf
 Verified By: Farabaugh Engineering and Testing, LLC
Test Reports
 FL47358_R0_TR_T295-24-Elite.pdf
47358.2 Elite Rib Wall Panel 26 ga Elite Rib Wall Panel Over Open Framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +266.93/-121.33
 Other: Per ASTM E330 tests over 18 ga hat channel located at 2' on centers with Safety Factor of 1.5
Installation Instructions
 FL47358_R0_II_T311-24-Elite.pdf
 Verified By: Farabaugh Engineering and Testing, LLC
Test Reports
 FL47358_R0_TR_T311-24-Elite.pdf
47358.3 Elite Rib Wall Panel 29 ga Elite Rib Wall Panel Over Open Framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +27.73/-31.2
 Other: Per ASTM E330 tests over 14 ga open framing supports located at 5' on centers with Safety Factor of 1.5
Installation Instructions
 FL47358_R0_II_T293-24-Elite.pdf
 Verified By: Farabaugh Engineering and Testing, LLC
Test Reports
 FL47358_R0_TR_T293-24-Elite.pdf
47358.4 Elite Rib Wall Panel 26 ga Elite Rib Wall Panel Over Open Framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +31.2/-38.13
 Other: Per ASTM E330 tests over 14 ga open framing supports located at 5' on centers with Safety Factor of 1.5
Installation Instructions
 FL47358_R0_II_T297-24-Elite.pdf
 Verified By: Farabaugh Engineering and Testing, LLC
Test Reports
 FL47358_R0_TR_T297-24-Elite.pdf
47358.5 Elite Rib Wall Panel 26 ga Elite Rib Wall Panel Over Open Framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +55.53/-55.53
 Other: Per ASTM E330 tests over 14 ga open framing supports located at 4' on centers with Safety Factor of 1.5
Installation Instructions
 FL47358_R0_II_T299-24-Elite.pdf
 Verified By: Farabaugh Engineering and Testing, LLC
Test Reports
 FL47358_R0_TR_T299-24-Elite.pdf
47358.6 Elite Rib Wall Panel 29 ga Elite Rib Wall Panel Over Open Framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +48.53/-45.07
 Other: Per ASTM E330 tests over 18 ga hat channel located at 4' on centers with Safety Factor of 1.5
Installation Instructions
 FL47358_R0_II_T301-24-Elite.pdf
 Verified By: Farabaugh Engineering and Testing, LLC
Test Reports
 FL47358_R0_TR_T301-24-Elite.pdf
47358.7 Elite Rib Wall Panel 29 ga Elite Rib Wall Panel Over Open Framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +100.53/-72.8
 Other: Per ASTM E330 tests over 18 ga hat channel located at 3' on centers with Safety Factor of 1.5
Installation Instructions
 FL47358_R0_II_T303-24-Elite.pdf
 Verified By: Farabaugh Engineering and Testing, LLC
Test Reports
 FL47358_R0_TR_T303-24-Elite.pdf
47358.8 Elite Rib Wall Panel 29 ga Elite Rib Wall Panel Over Open Framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +263.67/-124.8
 Other: Per ASTM E330 tests over 18 ga hat channel located at 2' on centers with Safety Factor of 1.5
Installation Instructions
 FL47358_R0_II_T305-24-Elite.pdf
 Verified By: Farabaugh Engineering and Testing, LLC
Test Reports
 FL47358_R0_TR_T305-24-Elite.pdf
47358.9 Elite Rib Wall Panel 26 ga Elite Rib Wall Panel Over Open Framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +52/-52
 Other: Per ASTM E330 tests over 18 ga hat channel located at 4' on centers with Safety Factor of 1.5
Installation Instructions
 FL47358_R0_II_T307-24-Elite.pdf
 Verified By: Farabaugh Engineering and Testing, LLC
Test Reports
 FL47358_R0_TR_T307-24-Elite.pdf
47358.10 Elite Rib Wall Panel 26 ga Elite Rib Wall Panel Over Open Framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +107.47/-83.2
 Other: Per ASTM E330 tests over 18 ga hat channel located at 3' on centers with Safety Factor of 1.5
Installation Instructions
 FL47358_R0_II_T309-24-Elite.pdf
 Verified By: Farabaugh Engineering and Testing, LLC
Test Reports
 FL47358_R0_TR_T309-24-Elite.pdf
 