| 47358.1 |
Elite Rib Wall Panel |
29 ga Elite Rib Wall Panel Over Open Framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +48.53/-45.07 Other: Per ASTM E330 tests over 14 ga open framing supports located at 4' on centers with Safety Factor of 1.5 |
Installation Instructions FL47358_R0_II_T295-24-Elite.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47358_R0_TR_T295-24-Elite.pdf |
|
|
| 47358.2 |
Elite Rib Wall Panel |
26 ga Elite Rib Wall Panel Over Open Framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +266.93/-121.33 Other: Per ASTM E330 tests over 18 ga hat channel located at 2' on centers with Safety Factor of 1.5 |
Installation Instructions FL47358_R0_II_T311-24-Elite.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47358_R0_TR_T311-24-Elite.pdf |
|
|
| 47358.3 |
Elite Rib Wall Panel |
29 ga Elite Rib Wall Panel Over Open Framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +27.73/-31.2 Other: Per ASTM E330 tests over 14 ga open framing supports located at 5' on centers with Safety Factor of 1.5 |
Installation Instructions FL47358_R0_II_T293-24-Elite.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47358_R0_TR_T293-24-Elite.pdf |
|
|
| 47358.4 |
Elite Rib Wall Panel |
26 ga Elite Rib Wall Panel Over Open Framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +31.2/-38.13 Other: Per ASTM E330 tests over 14 ga open framing supports located at 5' on centers with Safety Factor of 1.5 |
Installation Instructions FL47358_R0_II_T297-24-Elite.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47358_R0_TR_T297-24-Elite.pdf |
|
|
| 47358.5 |
Elite Rib Wall Panel |
26 ga Elite Rib Wall Panel Over Open Framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +55.53/-55.53 Other: Per ASTM E330 tests over 14 ga open framing supports located at 4' on centers with Safety Factor of 1.5 |
Installation Instructions FL47358_R0_II_T299-24-Elite.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47358_R0_TR_T299-24-Elite.pdf |
|
|
| 47358.6 |
Elite Rib Wall Panel |
29 ga Elite Rib Wall Panel Over Open Framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +48.53/-45.07 Other: Per ASTM E330 tests over 18 ga hat channel located at 4' on centers with Safety Factor of 1.5 |
Installation Instructions FL47358_R0_II_T301-24-Elite.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47358_R0_TR_T301-24-Elite.pdf |
|
|
| 47358.7 |
Elite Rib Wall Panel |
29 ga Elite Rib Wall Panel Over Open Framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +100.53/-72.8 Other: Per ASTM E330 tests over 18 ga hat channel located at 3' on centers with Safety Factor of 1.5 |
Installation Instructions FL47358_R0_II_T303-24-Elite.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47358_R0_TR_T303-24-Elite.pdf |
|
|
| 47358.8 |
Elite Rib Wall Panel |
29 ga Elite Rib Wall Panel Over Open Framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +263.67/-124.8 Other: Per ASTM E330 tests over 18 ga hat channel located at 2' on centers with Safety Factor of 1.5 |
Installation Instructions FL47358_R0_II_T305-24-Elite.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47358_R0_TR_T305-24-Elite.pdf |
|
|
| 47358.9 |
Elite Rib Wall Panel |
26 ga Elite Rib Wall Panel Over Open Framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +52/-52 Other: Per ASTM E330 tests over 18 ga hat channel located at 4' on centers with Safety Factor of 1.5 |
Installation Instructions FL47358_R0_II_T307-24-Elite.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47358_R0_TR_T307-24-Elite.pdf |
|
|
| 47358.10 |
Elite Rib Wall Panel |
26 ga Elite Rib Wall Panel Over Open Framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +107.47/-83.2 Other: Per ASTM E330 tests over 18 ga hat channel located at 3' on centers with Safety Factor of 1.5 |
Installation Instructions FL47358_R0_II_T309-24-Elite.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL47358_R0_TR_T309-24-Elite.pdf |