| 11698.1 |
01 - Englert "Series 500" |
Roof Panel - 26 Gauge Steel, 21" Width, Attached to Plywood Deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-79 Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to manufacturer’s installation instructions as a supplemental guide for attachment. |
Installation Instructions FL11698_R8_II_1_S500_26ga_WoodDeck_EVALREPORT.pdf Verified By: James L. Buckner, P.E P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL11698_R8_AE_1_S500_26ga_WoodDeck_EVALREPORT.pdf Created by Independent Third Party: Yes |
|
|
| 11698.2 |
02 - Englert "Series 500" |
Roof Panel - 0.032" Aluminum, 21" Width, Attached to Plywood Deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-84 Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to manufacturer’s installation instructions as a supplemental guide for attachment. |
Installation Instructions FL11698_R8_II_2_S500_032Alum_WoodDeck_EVALREPORT.pdf Verified By: James L. Buckner, P.E P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL11698_R8_AE_2_S500_032Alum_WoodDeck_EVALREPORT.pdf Created by Independent Third Party: Yes |
|
|
| 11698.3 |
03 - Englert "Series 1000" |
Roof Panel - 24 Gauge Steel, 20" Width, Attached to Plywood Deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-52.5 Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to manufacturer’s installation instructions as a supplemental guide for attachment. |
Installation Instructions FL11698_R8_II_3_S1000_24ga_WoodDeck_EVALREPORT.pdf Verified By: James L. Buckner, P.E P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL11698_R8_AE_3_S1000_24ga_WoodDeck_EVALREPORT.pdf Created by Independent Third Party: Yes |
|
|
| 11698.4 |
04 - Englert "Series 1100" |
Roof Panel - 24 Gauge Steel, 16" Width, Attached to Plywood Deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-60 Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to manufacturer’s installation instructions as a supplemental guide for attachment. |
Installation Instructions FL11698_R8_II_4_S1100_24ga_WoodDeck_EVALREPORT.pdf Verified By: James L. Buckner, P.E P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL11698_R8_AE_4_S1100_24ga_WoodDeck_EVALREPORT.pdf Created by Independent Third Party: Yes |
|
|
| 11698.5 |
05 - Englert "Series 1100" |
Roof Panel - 0.032" Aluminum, 16" Width, Attached to Plywood Deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-SeeTable Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to manufacturer’s installation instructions as a supplemental guide for attachment. |
Installation Instructions FL11698_R8_II_5_S1100_032Alum_WoodDeck_EVALREPORT.pdf Verified By: James L. Buckner, P.E P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL11698_R8_AE_5_S1100_032Alum_WoodDeck_EVALREPORT.pdf Created by Independent Third Party: Yes |
|
|
| 11698.6 |
06 - Englert "Series 1101" |
Roof Panel - 24 Gauge Steel, 16" Width, Attached to Plywood Deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-165 max. Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to manufacturer’s installation instructions as a supplemental guide for attachment. |
Installation Instructions FL11698_R8_II_6_S1101_24ga_WoodDeck_EVALREPORT.pdf Verified By: James L. Buckner, P.E P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL11698_R8_AE_6_S1101_24ga_WoodDeck_EVALREPORT.pdf Created by Independent Third Party: Yes |
|
|
| 11698.7 |
07 - Englert "Series 1500" |
Roof Panel - 24 Gauge Steel, 15-1/4" Width, Attached to Plywood Deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-150max Other: Refer to Evaluation Report for Limitations and Conditions of Use. Refer to manufacturer’s installation instructions as a supplemental guide for attachment. |
Installation Instructions FL11698_R8_II_7_S1500_24ga_WoodDeck_EVALREPORT.pdf Verified By: James L. Buckner, P.E. P.E. #31242 Created by Independent Third Party: Yes Evaluation Reports FL11698_R8_AE_7_S1500_24ga_WoodDeck_EVALREPORT.pdf Created by Independent Third Party: Yes |