| 18568.1 |
5XPT OXO |
Aluminum Thermally Broken Sliding Glass Door |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Missile Level D (CCLI 08-074), Missile Level A (CCLI 08-082) & Missile level D (CCLI 10-256). See as tested drawings and test reports for size, design pressure, glazing configuration, product operation and installation. See GlazingDetails.pdf for DLO, Spacer Material and Interlayer Components. Setting blocks in accordance with Section 2411.3.3.1 of the 8th Edition (2023) FBC shall be used when fixed glass widths exceed 3 feet. |
Installation Instructions FL18568_R3_II_CCLI 10-256 as tested.pdf FL18568_R3_II_CCLI08074 as tested.pdf FL18568_R3_II_CCLI08082 as tested.pdf Verified By: Construction Consulting Laboratory Test Reports FL18568_R3_TR_CCLI 10-256.pdf FL18568_R3_TR_CCLI08074.pdf FL18568_R3_TR_CCLI08082.pdf FL18568_R3_TR_GlazingDetails.pdf |
|
|
| 18568.2 |
5XPT OXXO |
Aluminum Thermally Broken Sliding Glass Door |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Missile Level D. See as tested drawings and test reports for size, design pressure, glazing configuration, product operation and installation. See GlazingDetails.pdf for DLO, Spacer Material and Interlayer Components. Setting blocks in accordance with Section 2411.3.3.1 of the 8th Edition (2023) FBC shall be used when fixed glass widths exceed 3 feet. |
Installation Instructions FL18568_R3_II_CCLI 10-256 as tested.pdf Verified By: Construction Consulting Laboratory Test Reports FL18568_R3_TR_CCLI 10-256.pdf FL18568_R3_TR_GlazingDetails.pdf |
|
|
| 18568.3 |
5XPT OXXO |
Aluminum Thermally Broken Sliding Glass Door |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Missile Level D. See as tested drawings and test reports for size, design pressure, glazing configuration, product operation and installation. See GlazingDetails.pdf for DLO, Spacer Material and Interlayer Components. Setting blocks in accordance with Section 2411.3.3.1 of the 8th Edition (2023) FBC shall be used when fixed glass widths exceed 3 feet. |
Installation Instructions FL18568_R3_II_92110.01-801-18 as tested.pdf FL18568_R3_II_92110.02-801-18 as tested.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - York, PA Test Reports FL18568_R3_TR_92110.01-801-18.pdf FL18568_R3_TR_92110.02-801-18.pdf FL18568_R3_TR_GlazingDetails.pdf |