| 31653.1 |
01: 150MS 1.5" Mechanical Seam 032 Aluminum 20" panel |
150MS 1.5" mechanical seam panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank | 20" coverage |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-178 Other: 178psf with clips @ 13", 76psf @ 19" |
Installation Instructions FL31653_R5_II_32Al_150MS_plywood_20in_13_19.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL31653_R5_AE_32Al_150MS_plywood_20in_13_19.pdf Created by Independent Third Party: Yes |
|
|
| 31653.2 |
02: 150MS 1.5" Mechanical Seam 24ga |
150MS 1.5" mechanical seam panel from 24ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-198.5 Other: 198.5 with clips @ 8" oc, 166psf @ 16" oc |
Installation Instructions FL31653_R5_II_24ga_150MS_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL31653_R5_AE_24ga_150MS_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 31653.3 |
03: 150MS 1.5" Mechanical Seam 26ga |
150MS 1.5" mechanical seam panel from 26ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-218.8 Other: 218.8psf with clips @ 12" oc |
Installation Instructions FL31653_R5_II_26ga_150MS_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL31653_R5_AE_26ga_150MS_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 31653.4 |
04: 150MS 1.5" Mechanical Seam 032 Aluminum 20" panel |
150MS 1.5" mechanical seam panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank | 20" coverage |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-198.5 Other: 198.5psf with clips @ 10.5", 156psf @ 13" |
Installation Instructions FL31653_R5_II_32Al_150MS_plywood_20in.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL31653_R5_AE_32Al_150MS_plywood_20in.pdf Created by Independent Third Party: Yes |
|
|
| 31653.5 |
05: 150MS 1.5" Mechanical Seam 16oz Copper |
150MS 1.5" mechanical seam panel from 16oz copper or thicker on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-198.5 Other: 198.5psf with 3" clip @ 12" oc, 149psf with 2" clip @ 16" oc |
Installation Instructions FL31653_R5_II_16ozCu_150MS_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL31653_R5_AE_16ozCu_150MS_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 31653.6 |
06: 200MS 2.0" Mechanical Seam 24ga |
200MS 2.0" mechanical seam panel from 24ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-228.5 Other: 228.5psf with clips @ 9", 194.75psf with clips @ 19" |
Installation Instructions FL31653_R5_II_24ga_200MS_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL31653_R5_AE_24ga_200MS_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 31653.7 |
07: 200MS 2.0" Mechanical Seam 032 Aluminum |
200MS 2.0" mechanical seam panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-200 Other: 200psf with clips @ 9" oc, 167psf with clips @ 19" oc |
Installation Instructions FL31653_R5_II_32Al_200MS_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL31653_R5_AE_32Al_200MS_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 31653.8 |
08: 150MS 1.5" Mechanical Seam 032 Aluminum |
150MS 1.5" mechanical seam panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-213.5 Other: 213.5psf with clips @ 8", 138.5psf @ with clips @ 16" oc |
Installation Instructions FL31653_R5_II_32Al_150MS_plywood.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL31653_R5_AE_32Al_150MS_plywood.pdf Created by Independent Third Party: Yes |
|
|
| 31653.9 |
09: 150MS 1.5" Mechanical Seam 032 Aluminum |
150MS 1.5" mechanical seam panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-206 Other: 206psf with clips @ 8" oc, 101psf with clips @ 16" oc |
Installation Instructions FL31653_R5_II_32Al_150MS_plywood-nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL31653_R5_AE_32Al_150MS_plywood-nonHVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 31653.10 |
10: 150MS 1.5" Mechanical Seam 24ga |
150MS 1.5" mechanical seam panel from 24ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-198.5 Other: 198.5psf with clips @ 8" oc, 168.5psf with clips @ 16" oc |
Installation Instructions FL31653_R5_II_24ga_150MS_plywood-nonHVHZ.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL31653_R5_AE_24ga_150MS_plywood-nonHVHZ.pdf Created by Independent Third Party: Yes |
|
|
| 31653.11 |
11: 150MS 1.5" Mechanical Seam 16oz Copper |
150MS 1.5" mechanical seam panel from 16oz copper or thicker on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-159.25 Other: See report for details |
Installation Instructions FL31653_R5_II_16ozCu_150MS_plywood im.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL31653_R5_AE_16ozCu_150MS_plywood im.pdf Created by Independent Third Party: Yes |
|
|
| 31653.12 |
12: 150MS 1.5" Mechanical Seam 24ga |
150MS 1.5" mechanical seam panel from 24ga (min) on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-189.25 Other: See report for details |
Installation Instructions FL31653_R5_II_24ga_150MS_plywood im.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL31653_R5_AE_24ga_150MS_plywood im.pdf Created by Independent Third Party: Yes |
|
|
| 31653.13 |
13: 150MS 1.5" Mechanical Seam 032 Aluminum |
150MS 1.5" mechanical seam panel from nominal 0.032" aluminum or thicker on 15/32" (min) plywood or 3/4" (min) wood plank |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-159.25 Other: See report for details |
Installation Instructions FL31653_R5_II_32Al_150MS_plywood im.pdf Verified By: David Eng, PE 81377 Created by Independent Third Party: Yes Evaluation Reports FL31653_R5_AE_32Al_150MS_plywood im.pdf Created by Independent Third Party: Yes |