| 28445.1 |
Premium Coastal DH Operator (48"x84") Mulled to DH Picture (56"x84") Combination (IG) |
1104 Double Hung (48"x84") Mulled to 1109 DH Picture (56"x84") Insulated Glass. Maximum Tributary Width = 52" based on mull testing & CCL 449-H-074.15 and .17. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: Complies with ASTM E1300. DH IG comprised of one lite of 5/32" annealed//8.0mm Endur Spacer//Lami lite comprised of two lites of 3/32" annealed with .090" PVB interlayer. Picture IG comprised of one lite of 1/4" annealed//8mm Endur spacer//Lami lite comprised of two lites of 3/16" annealed with .090" PVB interlayer. |
Certification Agency Certificate FL28445_R4_C_CAC_449-H-037_17_19-20.pdf FL28445_R4_C_CAC_449-H-074_19-_21 DH.pdf FL28445_R4_C_CAC_449-H-074-15.pdf Quality Assurance Contract Expiration Date 10/15/2025 Installation Instructions FL28445_R4_II_1104-1105 DH Through Jamb.pdf FL28445_R4_II_45-18772 DH Oper-Picture Comb.pdf FL28445_R4_II_8120, 1104, 1105 Double Hung fin 45-01290.pdf FL28445_R4_II_8120, 1104, 1105 Fin 45-01387.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 28445.2 |
Premium Coastal DH Operator (48"x84") Mulled to DH Picture (56"x84") Combination (IG) |
1104 Double Hung (48"x84") Mulled to 1109 DH Picture (56"x84") Insulated Glass. Maximum Tributary Width = 52" based on mull testing & CCL 449-H-074.15 and .17. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: Complies with ASTM E1300. DH IG comprised of one lite of 5/32" annealed//8.0mm Endur Spacer//Lami lite comprised of two lites of 3/32" annealed with .090" PVB interlayer. Picture IG comprised of one lite of 1/4" annealed//8mm Endur spacer//Lami lite comprised of two lites of 3/16" annealed with .090" PVB interlayer. |
Certification Agency Certificate FL28445_R4_C_CAC_449-H-037_17_19-20.pdf FL28445_R4_C_CAC_449-H-074-15.pdf FL28445_R4_C_CAC_FL28445_R3_C_CAC_449-H-074_19-_21 DH.pdf Quality Assurance Contract Expiration Date 11/04/2026 Installation Instructions FL28445_R4_II_1104-1105 Through Jamb 45-28432.pdf FL28445_R4_II_45-18772.pdf FL28445_R4_II_8120, 1104, 1105 Double Hung fin 45-01290.pdf FL28445_R4_II_8120, 1104, 1105 Fin 45-01387.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 28445.3 |
Premium Coastal DH Operator (48"x84") Mulled to DH Picture (56"x84") Combination (Monolithic) |
1105 Double Hung (48"x84") Mulled to 1108 DH Picture (56"x84") Monolithic Glass. Maximum Tributary Width = 52" based on mull testing & CCL 449-H-074.15 and .17. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: Complies with ASTM E1300. DH Operator Monolithic 5/16" Laminated lite consists of two lites of 1/8" annealed with .090" PVB interlayer. DH Picture Monolithic 15/32" laminated lite consists of two lites of 4.7mm annealed or heat strengthened with .090" SPG interlayer. |
Certification Agency Certificate FL28445_R4_C_CAC_449-H-037_17_19-20.pdf FL28445_R4_C_CAC_449-H-074_19-_21 DH.pdf FL28445_R4_C_CAC_449-H-074-15.pdf Quality Assurance Contract Expiration Date 10/15/2025 Installation Instructions FL28445_R4_II_1104-1105 Through Jamb 45-28432.pdf FL28445_R4_II_45-18772 DH Oper-Picture Comb.pdf FL28445_R4_II_8120, 1104, 1105 Double Hung fin 45-01290.pdf FL28445_R4_II_8120, 1104, 1105 Fin 45-01387.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 28445.4 |
Premium Coastal Double Hung w/Transom |
1104/1105 Double-Hung (48"x96") with 1110/1111 DH Transom (48"x42") Stacked Above (Monolithic and Insulated) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +55/-70 Other: Complies with ASTM E1300. Monolithic 5/16" Laminated lite consists of two lites of 1/8" annealed with .090" PVB interlayer. Insulated glass comprised of one lite of 5/32" annealed//8.0mm Endur Spacer//Lami lite comprised of two lites of 3/32" annealed with .090" PVB interlayer. |
Certification Agency Certificate FL28445_R4_C_CAC_449-H-074_19-_21 DH.pdf Quality Assurance Contract Expiration Date 05/03/2027 Installation Instructions FL28445_R4_II_1104-1105 Through Jamb 45-28432.pdf FL28445_R4_II_1104-1105-1110-1111 DH Operator with DH Transom Stacked Above ESP024264P-2079.1.pdf Verified By: Window and Door Manufacturer Association Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |