Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL9482-R8
Application Type Revision
Code Version 2026
Application Status Pending FBC Approval
 
Comments
Archived
 
Product Manufacturer Metal Sales Manufacturing, LLC
Address/Phone/Email 7800 Highway 60
Sellersburg, IN 47172
(502) 855-4300
dstermer@metalsales.us.com
 
Authorized Signature David Stermer
dstermer@metalsales.us.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Panel Walls
Subcategory Siding
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Bala Sockalingam
Florida License PE-62240
Quality Assurance Entity Keystone Certifications, Inc.
Quality Assurance Contract Expiration Date 02/10/2033
Validated By Yoosef Lavi, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL9482_R8_COI_CertificateIndependence.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E15922017
ASTM E3302021
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 10/03/2026
Date Validated 10/13/2026
Date Pending FBC Approval 10/17/2026
 
Summary of Products
FL # Model, Number or Name Description
9482.1 7/8" Corrugated Panel Min 24 ga., 34.67" wide coverage through fastened wall panel
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +175/-175
 Other: Allowable positive and negative design load of 30 psf at support spacing of 96" o.c. and 175 psf at support spacing of 24" o.c.
Installation Instructions
 FL9482_R8_II_EvaluationReportC3057_1.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL9482_R8_AE_EvaluationReportC3057_1.pdf
 Created by Independent Third Party: Yes
9482.2 Classic Rib Min 26 ga., 36" wide wall panel fastened to steel supports
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +110/-110
 Other: Allowable positive and negative design load of 110 psf at support spacing of 24" o.c. and 30 psf at support spacing of 48" o.c.
Installation Instructions
 FL9482_R8_II_EvaluationReportC3057_2.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL9482_R8_AE_EvaluationReportC3057_2.pdf
 Created by Independent Third Party: Yes
9482.3 Classic Rib Min 26 ga., 36" wide wall panel fastened to min 18 ga. steel supports
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +N/A/-156.6
 Other: Outward load of 156.6 psf at fastener spacing of 18" o.c.
Installation Instructions
 FL9482_R8_II_EvaluationReportC3057_3.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL9482_R8_AE_EvaluationReportC3057_3.pdf
 Created by Independent Third Party: Yes
9482.4 Classic Rib Min 29 ga., 36" wide wall panel fastened to wood supports
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +120/-120
 Other: Allowable positive and negative design load of 120 psf at support spacing of 24" o.c.
Installation Instructions
 FL9482_R8_II_EvaluationReportC3057_4.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL9482_R8_AE_EvaluationReportC3057_4.pdf
 Created by Independent Third Party: Yes
9482.5 R-Panel or PBR-Panel Min 26 ga., 36" wide wall panel fastened to steel supports
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +120/-120
 Other: Allowable positive and negative design load of 120 psf at support spacing of 24" o.c. and 45 psf at support spacing of 60" o.c.
Installation Instructions
 FL9482_R8_II_EvaluationReportC3057_5.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL9482_R8_AE_EvaluationReportC3057_5.pdf
 Created by Independent Third Party: Yes
9482.6 R-Panel or PBR-Panel Min 26 ga., 36" wide wall panel fastened to min 18 ga. steel supports
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +N/A/-133.3
 Other: Outward load of 133.3 psf at fastener spacing of 18" o.c.
Installation Instructions
 FL9482_R8_II_EvaluationReportC3057_6.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL9482_R8_AE_EvaluationReportC3057_6.pdf
 Created by Independent Third Party: Yes
9482.7 Soffit Panel Min 24 ga., 12" wide, wall panel
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +55/-55
 Other: Allowable positive and negative design load of 55 psf at support spacing of 48" o.c.
Installation Instructions
 FL9482_R8_II_EvaluationReportC3057_7.pdf
 Verified By: Bala Sockalingam PE 62240
 Created by Independent Third Party: Yes
Evaluation Reports
 FL9482_R8_AE_EvaluationReportC3057_7.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts: