| 30343.1 | 01: 26ga 5V Crimp over plywood | 26ga (min) 5V Crimp over 15/32" (min) plywood | 
| Limits of Use Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-108.5
 Other: 108.5psf with 12"-12" pattern at 12"oc
 | Installation Instructions FL30343_R3_II_26ga_5VCrimp_plywood.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
 Evaluation Reports
 FL30343_R3_AE_26ga_5VCrimp_plywood.pdf
 Created by Independent Third Party: Yes
 | 
										
	
		|  | 
| 30343.2 | 02: 26ga PermaShield over plywood | 26ga (min) PermaShield screw strip over 15/32" (min) plywood | 
| Limits of Use Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-116
 Other: 116psf fastener every hole WITH sealant, 71psf fastener every other hole
 | Installation Instructions FL30343_R3_II_26ga_PermaShield_plywood.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
 Evaluation Reports
 FL30343_R3_AE_26ga_PermaShield_plywood.pdf
 Created by Independent Third Party: Yes
 | 
										
	
		|  | 
| 30343.3 | 03: 032 Aluminum PermaShield over plywood | Nominally 032 or thicker aluminum PermaShield screw strip over 15/32" (min) plywood | 
| Limits of Use Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-153.5
 Other: 153.5 with fastener every hole WITH sealant, 86psf with fastener every hole with OUT sealant.
 | Installation Instructions FL30343_R3_II_032Al_PermaShield_plywood.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
 Evaluation Reports
 FL30343_R3_AE_032Al_PermaShield_plywood.pdf
 Created by Independent Third Party: Yes
 | 
										
	
		|  | 
| 30343.4 | 04: 26ga TuffRib over plywood | 26ga (min) TuffRib over 15/32" (min) plywood | 
| Limits of Use Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-123.5
 Other: 123.5psf with 6.5"-2.5"-6.5"-2.5" fastener pattern @ 12" oc, 82.25psf with 9"-9"-9" fastener pattern @ 24" oc
 | Installation Instructions FL30343_R3_II_26ga_TuffRib_plywood.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
 Evaluation Reports
 FL30343_R3_AE_26ga_TuffRib_plywood.pdf
 Created by Independent Third Party: Yes
 | 
										
	
		|  | 
| 30343.5 | 05: 032 Aluminum DuraSeam over plywood | Nominally 0.032" or thicker aluminum DuraSeam over 15/32" (min) plywood | 
| Limits of Use Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-108.5
 Other: 108.5 psf with clips @ 18" oc
 | Installation Instructions FL30343_R3_II_032Al_DuraSeam_plywood.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
 Evaluation Reports
 FL30343_R3_AE_032Al_DuraSeam_plywood.pdf
 Created by Independent Third Party: Yes
 | 
										
	
		|  | 
| 30343.6 | 06: 26ga DuraSeam over plywood | 26ga (min) DuraSeam over 15/32" (min) plywood | 
| Limits of Use Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-93.5
 Other: 93.5psf with clips @ 12" oc, 63.5psf with clips @ 16" oc
 | Installation Instructions FL30343_R3_II_26ga_DuraSeam_plywood.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
 Evaluation Reports
 FL30343_R3_AE_26ga_DuraSeam_plywood.pdf
 Created by Independent Third Party: Yes
 | 
										
	
		|  | 
| 30343.7 | 07: 29ga TuffRib over plywood | 29ga (min) TuffRib over 15/32" (min) plywood | Fastener in the rib | 
| Limits of Use Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-123.5
 Other: 123.5 psf with 9"-9"-9" fastener pattern @ 12" oc, 56psf @ 24" oc
 | Installation Instructions FL30343_R3_II_29ga_TuffRib_Plywood-rib.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
 Evaluation Reports
 FL30343_R3_AE_29ga_TuffRib_Plywood-rib.pdf
 Created by Independent Third Party: Yes
 | 
										
	
		|  | 
| 30343.8 | 08: 29ga TuffRib on 1x4 battens over plywood | 29ga (min) TuffRib on 1x4 (nom) battens over 15/32" (min) plywood | 
| Limits of Use Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-131
 Other: 131 psf with 9"-9"-9" fastener pattern @ 12" oc, 78.5psf @ 24" oc
 | Installation Instructions FL30343_R3_II_29ga_TuffRib_1x4.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
 Evaluation Reports
 FL30343_R3_AE_29ga_TuffRib_1x4.pdf
 Created by Independent Third Party: Yes
 | 
										
	
		|  | 
| 30343.9 | 09: 29ga TuffRib over plywood | 29ga (min) TuffRib over 15/32" (min) plywood | 
| Limits of Use Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: N/A
 Design Pressure: +N/A/-93.5
 Other: 93.5 psf with 9"-9"-9" fastener pattern @ 12" oc, 56psf @ 24" oc
 | Installation Instructions FL30343_R3_II_29ga_TuffRib_plywood.pdf
 Verified By: David Eng, PE 81377
 Created by Independent Third Party: Yes
 Evaluation Reports
 FL30343_R3_AE_29ga_TuffRib_plywood.pdf
 Created by Independent Third Party: Yes
 |