| 20716.1 |
58MM END RETENTION AND NON RETENTION ROLL SHUTTER SYSTEM DRAWING NUMBER 20-171 |
Extruded aluminum slats interlocked together thru knuckles and retained by tracks to provide hurricane protection |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile A.S.D. Pressure rating End Retention Slat: +30, -30 p.s.f. at 22'-10" span (see remaining spans on sheet 12) and +25, -25 p.s.f. at 8'-0" span for Non End Retention Slat wall mounted in concrete (see remaining spans on sheet 24) |
Installation Instructions FL20716_R2_II_58MM_ER-NER_Roll_Up_InstallationInstructions.pdf Verified By: WALTER A. TILLIT JR, PE PE-44167 Created by Independent Third Party: Yes Evaluation Reports FL20716_R2_AE_EvaluationReport.pdf Created by Independent Third Party: Yes |