| 36841.1 |
EcoVent Ridge Vent |
Exhaust vent |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +NA/-202.5 Other: 1) Must be installed in accordance with the manufacturer's installation instructions. 2) Approved to be installed over asphalt shingles 3) Approved to be installed on minimum roof pitch of 3:12 4) Shall not be installed on roofs with a mean roof height greater than 33 ft. |
Certification Agency Certificate FL36841_R2_C_CAC_Certificate EcoVent Ridge Vent 5.pdf Quality Assurance Contract Expiration Date 12/31/2026 Installation Instructions FL36841_R2_II_602713_EcoVent_data-sheet_05May25.pdf Verified By: PRI Construction Materials Technologies Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 36841.2 |
Highpoint® Intake |
Intake Vent |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +NA/-187.5 Other: 1) Must be installed in accordance with the manufacturer's installation instructions. 2) Approved to be installed over asphalt shingles 3) Approved to be installed on roof pitches from 3:12 to 16:12 4) Shall not be installed on roofs with a mean roof height greater than 33 ft. |
Certification Agency Certificate FL36841_R2_C_CAC_117C Certificate HighPoint Intake.pdf Quality Assurance Contract Expiration Date 11/05/2025 Installation Instructions FL36841_R2_II_HIGHPOINT Intake App Inst English_v5.pdf Verified By: PRI Construction Materials Technologies Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 36841.3 |
Highpoint® InvisaRidgeâ„¢ |
Exhaust Vent |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +NA/-202.5 Other: 1) Must be installed in accordance with the manufacturer's installation instructions. 2) Approved to be installed over asphalt shingles 3) Approved to be installed on minimum roof pitch of 3:12 4) Shall not be installed on roofs with a mean roof height greater than 33 ft. |
Certification Agency Certificate FL36841_R2_C_CAC_117C Certificate Highpoint Invisaridge.pdf Quality Assurance Contract Expiration Date 11/05/2025 Installation Instructions FL36841_R2_II_HighPoint_InvisaRidge_Installation_Instructions.pdf Verified By: PRI Construction Materials Technologies Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 36841.4 |
Highpoint® Performance Ridge XL |
Exhaust Vent |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +NA/-202.5 Other: 1) Must be installed in accordance with the manufacturer's installation instructions. 2) Approved to be installed over asphalt shingles 3) Approved to be installed on minimum roof pitch of 3:12 4) Shall not be installed on roofs with a mean roof height greater than 33 ft. |
Certification Agency Certificate FL36841_R2_C_CAC_117C Certificate HighPoint Performance Ridge XL.pdf Quality Assurance Contract Expiration Date 11/05/2025 Installation Instructions FL36841_R2_II_Performance Ridge XL Installation Instructions.pdf Verified By: PRI Construction Materials Technologies Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 36841.5 |
TruRidge® |
Exhaust vent |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +NA/-202.5 Other: 1) Must be installed in accordance with the manufacturer's installation instructions. 2) Approved to be installed over asphalt shingles 3) Approved to be installed on roof pitches from 3:12 to 16:12 4) Shall not be installed on roofs with a mean roof height greater than 33 ft. |
Certification Agency Certificate FL36841_R2_C_CAC_117C Certificate Truridge.pdf Quality Assurance Contract Expiration Date 11/05/2025 Installation Instructions FL36841_R2_II_TruRidge Installation Instructions.pdf Verified By: PRI Construction Materials Technologies Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 36841.6 |
TruRidge® All-Weather |
Exhaust Vent |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +NA/-202.5 Other: 1) Must be installed in accordance with the manufacturer's installation instructions. 2) Approved to be installed over asphalt shingles 3) Approved to be installed on roof pitches from 3:12 to 16:12 4) Shall not be installed on roofs with a mean roof height greater than 33 ft. |
Certification Agency Certificate FL36841_R2_C_CAC_117C Certificate Truridge All-Weather.pdf Quality Assurance Contract Expiration Date 11/05/2025 Installation Instructions FL36841_R2_II_TruRidge-All-Weather-Installation-Instructions-English.pdf Verified By: PRI Construction Materials Technologies Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |