| 4091.1 |
SH-8100 |
8100 Vinyl Flange/Fin Frame Single Hung |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +50/-50 Other: SH-8100, Max. size 53.125" x 76". Glass complies with ASTM E1300. |
Installation Instructions FL4091_R12_II_CWS-154J_NI.pdf Verified By: Lucas A. Turner 58201 Created by Independent Third Party: Yes Evaluation Reports FL4091_R12_AE_EvalReport154J_NI.pdf Created by Independent Third Party: Yes |
|
|
| 4091.2 |
SH-8100 |
SH-8100 Vinyl Single Hung, Non-Impact. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: SH-8100 Vinyl Single Hung, OX, Max. size 52" x 71", see installation dwgs. for DP. Glass complies with ASTM E1300. |
Installation Instructions FL4091_R12_II_CWS-485G_NI.pdf Verified By: Lucas A. Turner 58201 Created by Independent Third Party: Yes Evaluation Reports FL4091_R12_AE_EvalReport485G_NI.pdf Created by Independent Third Party: Yes |
|
|
| 4091.3 |
SH-8100 Continuous Head & Sill |
SH-8100 Vinyl Single Hung, Continuous Head & Sill, Non-Impact. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: SH-8100 Cont. Hd. & Sill, Max. size 72 7/8" x 61 3/4", DP +67.5/-70 psf. Glass complies with ASTM E1300. |
Installation Instructions FL4091_R12_II_CWS-442G_NI.pdf Verified By: Lucas A. Turner 58201 Created by Independent Third Party: Yes Evaluation Reports FL4091_R12_AE_EvalReport442G_NI.pdf Created by Independent Third Party: Yes |
|
|
| 4091.4 |
SH-8100 Continuous Head & Sill |
SH-8100 Vinyl Single Hung, Cont. Head & Sill, Non-Impact. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: SH-8100 Cont. Hd. & Sill, Max. size 74 1/8" x 72", see chart on installation dwgs. for DP. Glass complies with ASTM E1300. |
Installation Instructions FL4091_R12_II_CWS-492G_NI.pdf Verified By: Lucas A. Turner 58201 Created by Independent Third Party: Yes Evaluation Reports FL4091_R12_AE_EvalReport492G_NI.pdf Created by Independent Third Party: Yes |
|
|
| 4091.5 |
SH-8100 Oriel |
8100 Vinyl Single Hung Oriel w/ HD Meeting Rail |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +60/-60 Other: SH-8100, Max. size 52" x 96", Oriel. Glass complies with ASTM E1300. |
Installation Instructions FL4091_R12_II_CWS-293H_NI.pdf Verified By: Lucas A. Turner 58201 Created by Independent Third Party: Yes Evaluation Reports FL4091_R12_AE_EvalReport293H_NI.pdf Created by Independent Third Party: Yes |
|
|
| 4091.6 |
SH-8100/FX 8150 Cont. Hd. & Sill - Non-Impact |
Single Hung and Fixed Window combination with Cont. Hd. & Sill Non-Impact |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See installation drawings for maximum size limitations and performance criteria in WZ3 and HVHZ regions. Glass complies with ASTM E1300. |
Installation Instructions FL4091_R12_II_CWS-1270A_NI.pdf Verified By: Lucas A. Turner 58201 Created by Independent Third Party: Yes Evaluation Reports FL4091_R12_AE_EvalReport1270A_NI.pdf Created by Independent Third Party: Yes |