Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL23998-R13
Application Type Revision
Code Version 2023
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Quaker Window Products
Address/Phone/Email PO Box 128
504 Highway 63 South
Freeburg, MO 65035
(800) 347-0438   Ext 1308
fgrunewald@quakerwindows.com
 
Authorized Signature Fred Grunewald
fgrunewald@quakerwindows.com
 
Technical Representative Jacob Wildhaber
Address/Phone/Email 504 HIGHWAY 63 SOUTH
FREEBURG, MO 65035
(800) 347-0438
jwildhaber@quakerwindows.com
 
Quality Assurance Representative Mike Schwartz
Address/Phone/Email P.O. Box 128
Freeburg, MO 65035
(800) 347-0438
mschwartz@quakerwindows.com
 
Category Windows
Subcategory Fixed
 
Compliance Method Certification Mark or Listing
 
Certification Agency National Accreditation & Management Institute
Validated By National Accreditation & Management Institute
 
 
 
Referenced Standard and Year (of Standard)
StandardYear
AAMA 5062016
AAMA/WDMA/CSA 101/I.S.2/A4402008
ASTM E18862013
ASTM E19962014
ASTM E19962017
 
Equivalence of Product Standards
Certified By

Florida Licensed Professional Engineer or Architect
FL23998_R13_Equiv_P7049.01-122-34 R0 Equivalency Letter M700 Fixed 2.14.23.pdf
 
 
 
 
Product Approval Method Method 1 Option A
 
Date Submitted 02/11/2026
Date Validated 02/13/2026
Date Pending FBC Approval
Date Approved 02/13/2026
 
Summary of Products
FL # Model, Number or Name Description
23998.1 Series M600/Modern Vu Fixed Window 3 1/4" Thermally Broken Aluminum Fixed Window
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +70/-70
 Other: 72"w x 120"h Fixed Window. AAMA AW PG70 Rating. 1" Insulating Glass (5/16" Tempered Lights w/ 3/8" Spacer.) Max DLO 69 1/8" x 117 1/8". Anchorage by Nail Fin or Strap Anchor. See Installation Instructions Elev. A. Glass conforms to ASTM E1300
Certification Agency Certificate
 FL23998_R13_C_CAC_NI013439-R3.pdf
Quality Assurance Contract Expiration Date
 09/30/2028
Installation Instructions
 FL23998_R13_II_M600 Fixed 72 x 120 2023_PE Sealed.pdf
 Verified By: Tanya A. Dolby, P.E. FL#93536
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23998_R13_AE_q9365.01-122-34-r1.pdf
 Created by Independent Third Party: Yes
23998.2 Series M600/Modern Vu Fixed Window 3 1/4" Thermally Broken Aluminum Fixed Window
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +70/-70
 Other: 60"w x 99"h Fixed Window. AAMA AW PG70 Rating. 1" Insulating Glass (1/4" Heat Strengthened Lights w/ 1/2" Spacer.) Max DLO 56 1/4" x 95 1/4". Anchorage by Nail Fin or Strap Anchor. See Installation Instructions Elev. A. Glass conforms to ASTM E1300
Certification Agency Certificate
 FL23998_R13_C_CAC_NI013415.04.pdf
Quality Assurance Contract Expiration Date
 06/30/2028
Installation Instructions
 FL23998_R13_II_M600 Fixed 60 x 99 2023_PE Sealed.pdf
 Verified By: Tanya A. Dolby, P.E. FL#93536
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23998_R13_AE_q9365.01-122-34-r1.pdf
 Created by Independent Third Party: Yes
23998.3 Series M600/Modern Vu Fixed Window 3 1/4" Thermally Broken Aluminum Fixed Window
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +80/-80
 Other: 60"w x 60"h Fixed Window. AAMA AW PG80 Rating. 1" Insulating Glass (1/4" Annealed Lights w/ 1/2" Spacer.) Max DLO 56 1/4" x 56 1/4". Anchorage by Nail Fin or Strap Anchor. See Installation Instructions Elev. A. Glass conforms to ASTM E1300
Certification Agency Certificate
 FL23998_R13_C_CAC_NI013415.01-R2.pdf
Quality Assurance Contract Expiration Date
 06/30/2028
Installation Instructions
 FL23998_R13_II_M600 Fixed 60 x 60 2023_PE Sealed.pdf
 Verified By: Tonya A. Dolby P.E. FL#93536
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23998_R13_AE_q9365.01-122-34-r1.pdf
 Created by Independent Third Party: Yes
23998.4 Series M600/Modern Vu Fixed Window 3 1/4" Thermally Broken 2 Light Aluminum Fixed Window
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +65/-65
 Other: 72"w x 96"h Fixed over Fixed Window with Horizontal Centerline 24" from Bottom. AAMA AW PG65 Rating. 1" Insulating Glass (1/4" Heat Strengthened Lights w/ 1/2" Spacer.) Max DLO 68 1/4" x 69 1/8" Top and 68 1/4" x 21 1/4" Btm. Anchorage by Nail Fin or Strap Anchor. See Installation Instructions Elev. A. Glass conforms to ASTM E1300
Certification Agency Certificate
 FL23998_R13_C_CAC_NI013415.03-R2.pdf
Quality Assurance Contract Expiration Date
 06/30/2028
Installation Instructions
 FL23998_R13_II_M600 Fixed ov Fixed 72 x 96 2023_PE Sealed (1).pdf
 Verified By: Tanya A. Dolby, P.E. FL#93536
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23998_R13_AE_q9365.01-122-34-r1.pdf
 Created by Independent Third Party: Yes
23998.5 Series M700 Fixed Impact Window 3 1/4" Thermally Broken Aluminum Fixed Impact Window
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +70/-70
 Other: Max 60" x 96" Fixed Window. AAMA AW-PG70-FW Rating. Missile Level D. Wind Zone 4. 1" Insulating Glass consisting of 1/4” Temp Ext. and 1/8" Ann x .090 SGP Interlayer x 1/8" Ann Lami Int. Max DLO 56 1/4" x 92 1/4”. Anchorage by Nail Fin, Trim & Clip, or Receptor. See Installation Drawings and Evaluation Report for full details. Glass conforms to ASTM E1300.
Certification Agency Certificate
 FL23998_R13_C_CAC_NI014240.02-R3.pdf
Quality Assurance Contract Expiration Date
 10/31/2028
Installation Instructions
 FL23998_R13_II_M700-Fixed.pdf
 Verified By: Lukas Turner, P.E. 58201
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23998_R13_AE_EvalReport-M700-Fixed-WZ4-FPA.pdf
 Created by Independent Third Party: Yes
23998.6 Series M700 Fixed Impact Window - PVB 3 1/4" Thermally Broken 42" X 72"Aluminum Fixed Impact Window
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +50/-50
 Other: Max 42" x 72" Fixed Window. AAMA AW-PG50-FW Rating. Missile Level D. Wind Zone 3. 1"Insulating Glass consisting of 1/4” Temp Ext. and 1/8" Ann x .090 PVB Interlayer x 1/8" Ann Lami Int. Max DLO 38 1/4" x 68 1/4”. See Installation Drawings and Evaluation Report for Anchorage Details. 15psf Water. Glass meets ASTM E1300.
Certification Agency Certificate
 FL23998_R13_C_CAC_NI014240.03-R1.pdf
Quality Assurance Contract Expiration Date
 09/30/2028
Installation Instructions
 FL23998_R13_II_2023 - M700 42x72 PVB 50 psf Fixed impact drawings_PE Sealed.pdf
 Verified By: Tanya A. Dolby P.E. 93536
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23998_R13_AE_Q9365.01-122-34-r1 M700.pdf
 Created by Independent Third Party: Yes
23998.7 Series M700/ Fixed Light over Louver Impact Window 3 1/4" Thermally Broken Aluminum Fixed over Louver Impact Window
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +65/-65
 Other: Max 60" x 94" Fixed Window. AAMA AW-PG70-F Rating. Missile Level D. Wind Zone 4. 1" Insulating Glass consisting of 1/4” Tempered Ext. and 1/8" Ann x .090 PVB Interlayer x 1/8" Ann Lami Int. Max DLO 56 1/4" x 69 1/4” Top Light and 52 1/4" x 17 1/2" PTAC Louver at bottom. See Installation Drawings and Evaluation Report for Anchorage Details. Glass meets ASTM E1300.
Certification Agency Certificate
 FL23998_R13_C_CAC_NI014352-R5.pdf
Quality Assurance Contract Expiration Date
 12/31/2028
Installation Instructions
 FL23998_R13_II_M700 Fixed Over Louver 2025.pdf
 Verified By: Tanya A. Dolby P.E. 93536
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23998_R13_AE_Q9365.01-122-34-r1 M700.pdf
 Created by Independent Third Party: Yes
23998.8 Series M700/Light Fixed Impact Window 3 1/4" Thermally Broken Aluminum Fixed Impact Window
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +70/-70
 Other: Max 48" x 60" Fixed Window. AAMA AW-PG70-F Rating. Missile Level D. Wind Zone 4. 1" Insulating Glass consisting of 1/4” Tempered Ext. and 1/8" Ann x .090 PVB Interlayer x 1/8" Ann Lami Int. Max DLO 44 1/4" x 56 1/4”. See Installation Drawings and Evaluation Report for Anchorage Details. Glass meets ASTM E1300
Certification Agency Certificate
 FL23998_R13_C_CAC_NI014240-R3.pdf
Quality Assurance Contract Expiration Date
 05/31/2029
Installation Instructions
 FL23998_R13_II_2023 - M700 48x60 PVB 70 psf Fixed impact drawings_PE Sealed.pdf
 Verified By: Tanya A. Dolby P.E. 93536
 Created by Independent Third Party: Yes
Evaluation Reports
 FL23998_R13_AE_Q9365.01-122-34-r1 M700.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex