| 48220.1 |
5V-Crimp |
Min. 26 ga., 24 wide through fastened roof panel over min. 19/32” thick plywood deck with fasteners through panel flat. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-149.6 Other: Uplift load of 149.6 psf at fastener spacing of 12" o.c. |
Installation Instructions FL48220_R1_II_EvaluationReportC3063_1.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL48220_R1_AE_EvaluationReportC3063_1.pdf Created by Independent Third Party: Yes |
|
|
| 48220.2 |
5V-Crimp |
Min. 26 ga., 24" wide through fastened roof panel over min. 15/32” thick plywood deck or 7/16" thick OSB with fasteners through panel rib. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-214.3 Other: Uplift load of 214.3 psf at fastener spacing of 3" o.c. |
Installation Instructions FL48220_R1_II_EvaluationReportC3063_2.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL48220_R1_AE_EvaluationReportC3063_2.pdf Created by Independent Third Party: Yes |
|
|
| 48220.3 |
Aluminum 5V-Crimp |
24" wide, nom 0.032" thick aluminum through fastened roof panel over min 15/32” thick plywood deck or 7/16" thick OSB with fasteners through panel rib. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-222.3 Other: Uplift load of 222.3 psf at fastener spacing of 3" o.c. |
Installation Instructions FL48220_R1_II_EvaluationReportC3063_3.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL48220_R1_AE_EvaluationReportC3063_3.pdf Created by Independent Third Party: Yes |
|
|
| 48220.4 |
Aluminum Image II |
16" wide, nom 0.032" thick aluminum concealed fastener roof panel over min 15/32” thick plywood deck or 7/16" thick OSB. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-206 Other: Uplift load of 206 psf at fastener spacing of 6" o.c. with sidelap adhesive and support strap. |
Installation Instructions FL48220_R1_II_EvaluationReportC3063_4.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL48220_R1_AE_EvaluationReportC3063_4.pdf Created by Independent Third Party: Yes |
|
|
| 48220.5 |
Aluminum Image II |
16" wide, nom 0.032" thick aluminum concealed fastener roof panel over min 15/32” thick plywood deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-222.3 Other: Uplift load of 222.3 psf at fastener spacing of 6" o.c. with support strap. |
Installation Instructions FL48220_R1_II_EvaluationReportC3063_5.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL48220_R1_AE_EvaluationReportC3063_5.pdf Created by Independent Third Party: Yes |
|
|
| 48220.6 |
Aluminum Vertical Seam |
Nom. 0.032" thick, 16" wide, aluminum standing seam roof panel over min. 15/32” thick plywood deck or 7/16" thick OSB. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-97.1 Other: Uplift load of 97.1 psf at clip spacing of 12" o.c. with sidelap adhesive. |
Installation Instructions FL48220_R1_II_EvaluationReportC3063_6.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL48220_R1_AE_EvaluationReportC3063_6.pdf Created by Independent Third Party: Yes |
|
|
| 48220.7 |
Aluminum Vertical Seam |
Nom. 0.032" thick, 16" wide, aluminum standing seam roof panel over min. 19/32” thick plywood deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-162 Other: Uplift load of 162.0 psf at clip spacing of 12" o.c. with support strap |
Installation Instructions FL48220_R1_II_EvaluationReportC3063_7.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL48220_R1_AE_EvaluationReportC3063_7.pdf Created by Independent Third Party: Yes |
|
|
| 48220.8 |
Image II |
16" wide, min. 26 ga. concealed fastener roof panel over min. 15/32" thick plywood deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-222 Other: Uplift load of 222 psf at fastener spacing of 6" o.c. with support strap |
Installation Instructions FL48220_R1_II_EvaluationReportC3063_8.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL48220_R1_AE_EvaluationReportC3063_8.pdf Created by Independent Third Party: Yes |
|
|
| 48220.9 |
Image II |
Min. 26 ga., 16" wide concealed fastened roof panel over min. 15/32” thick plywood deck or 7/16" thick OSB. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-183.5 Other: Uplift load of 183.5 psf at fastener spacing of 6" o.c. with sidelap adhesive and support strap |
Installation Instructions FL48220_R1_II_EvaluationReportC3063_9.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL48220_R1_AE_EvaluationReportC3063_9.pdf Created by Independent Third Party: Yes |
|
|
| 48220.10 |
Vertical Seam |
Max. 16" wide, min. 24 ga. standing seam roof panel over min. 15/32" thick plywood deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-200 Other: Uplift load of 200.0 psf at clip spacing of 12" o.c. with support strap and adhesive |
Installation Instructions FL48220_R1_II_EvaluationReportC3063_10.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL48220_R1_AE_EvaluationReportC3063_10.pdf Created by Independent Third Party: Yes |
|
|
| 48220.11 |
Vertical Seam |
Max. 18" wide, min. 24 ga. standing seam roof panel over min. 15/32" thick plywood deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-105 Other: Uplift load of 105.0 psf at clip spacing of 12" o.c. with sidelap adhesive. |
Installation Instructions FL48220_R1_II_EvaluationReportC3063_11.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL48220_R1_AE_EvaluationReportC3063_11.pdf Created by Independent Third Party: Yes |