| 13385.1 |
BR5-36 (40% Perforated) |
Stainless Steel Exposed Fastener Metal Wall Panel (40% Perforated) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See Evaluation Report for load/span limitations and various installation options. Product has not been evaluated for shear diaphragm capacity. |
Installation Instructions FL13385_R6_II_SteelExposedFastenerWallPanels_InstallDwg_Issue1_ss.pdf Verified By: Robert J. Amoruso, P.E. FL License No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL13385_R6_AE_ACE-PER-1155_Rev0_Exposed Fastener Perforated Metal Wall Panel_Appendices_ss.pdf Created by Independent Third Party: Yes |
|
|
| 13385.2 |
BR5-36 (40% Perforated) |
Aluminum Exposed Fastener Metal Wall Panel (40% Perforated) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See Evaluation Report for load/span limitations and various installation options. Product has not been evaluated for shear diaphragm capacity. |
Installation Instructions FL13385_R6_II_AluminumExposedFastenerWallPanels_InstallDwg_Issue1_ss.pdf Verified By: Robert J. Amoruso, P.E. FL License No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL13385_R6_AE_ACE-PER-1155_Rev0_Exposed Fastener Perforated Metal Wall Panel_Appendices_ss.pdf Created by Independent Third Party: Yes |
|
|
| 13385.3 |
Econolap 3/4 (40% Perforated) |
Stainless Steel Exposed Fastener Metal Wall Panel (40% Perforated) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See Evaluation Report for load/span limitations and various installation options. Product has not been evaluated for shear diaphragm capacity. |
Installation Instructions FL13385_R6_II_SteelExposedFastenerWallPanels_InstallDwg_Issue1_ss.pdf Verified By: Robert J. Amoruso, P.E. FL License No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL13385_R6_AE_ACE-PER-1155_Rev0_Exposed Fastener Perforated Metal Wall Panel_Appendices_ss.pdf Created by Independent Third Party: Yes |
|
|
| 13385.4 |
MR3-36 (40% Perforated) |
Aluminum Exposed Fastener Metal Wall Panel (40% Perforated) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See Evaluation Report for load/span limitations and various installation options. Product has not been evaluated for shear diaphragm capacity. |
Installation Instructions FL13385_R6_II_AluminumExposedFastenerWallPanels_InstallDwg_Issue1_ss.pdf Verified By: Robert J. Amoruso, P.E. FL License No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL13385_R6_AE_ACE-PER-1155_Rev0_Exposed Fastener Perforated Metal Wall Panel_Appendices_ss.pdf Created by Independent Third Party: Yes |
|
|
| 13385.5 |
MR3-36 (40% Perforated) |
Stainless Steel Exposed Fastener Metal Wall Panel (40% Perforated) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See Evaluation Report for load/span limitations and various installation options. Product has not been evaluated for shear diaphragm capacity. |
Installation Instructions FL13385_R6_II_SteelExposedFastenerWallPanels_InstallDwg_Issue1_ss.pdf Verified By: Robert J. Amoruso, P.E. FL License No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL13385_R6_AE_ACE-PER-1155_Rev0_Exposed Fastener Perforated Metal Wall Panel_Appendices_ss.pdf Created by Independent Third Party: Yes |
|
|
| 13385.6 |
Style-Rib (40% Perforated) |
Stainless Steel Exposed Fastener Metal Wall Panel (40% Perforated) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See Evaluation Report for load/span limitations and various installation options. Product has not been evaluated for shear diaphragm capacity. |
Installation Instructions FL13385_R6_II_SteelExposedFastenerWallPanels_InstallDwg_Issue1_ss.pdf Verified By: Robert J. Amoruso, P.E. FL License No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL13385_R6_AE_ACE-PER-1155_Rev0_Exposed Fastener Perforated Metal Wall Panel_Appendices_ss.pdf Created by Independent Third Party: Yes |
|
|
| 13385.7 |
Style-Rib (40% Perforated) |
Aluminum Exposed Fastener Metal Wall Panel (40% Perforated) |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: N/A Other: See Evaluation Report for load/span limitations and various installation options. Product has not been evaluated for shear diaphragm capacity. |
Installation Instructions FL13385_R6_II_Exposed Fastener Perforated Wall Non HVHZ_ss.pdf Verified By: Robert J. Amoruso, P.E. FL P.E. No. 49752 Created by Independent Third Party: Yes Evaluation Reports FL13385_R6_AE_ACE-PER-1155_Rev0_Exposed Fastener Perforated Metal Wall Panel_Appendices_ss.pdf Created by Independent Third Party: Yes |