| 42026.1 |
1" Snaplock Standing Seam Roof Panel |
26 ga 1" X 16" wide Snaplock Standing Seam over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +n/a/-22.5 psf Other: Per UL580 test over 15/32" Plywood w/ fasteners at 16" on centers with Safety Factor of 2.0 |
Installation Instructions FL42026_R1_II_T335-22.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL42026_R1_TR_T335-22.pdf |
|
|
| 42026.2 |
1-1/2" Snaplock Standing Seam Roof Panel |
26 ga 1-1/2" X 16" wide Snaplock Standing Seam over 15/32" Plywood |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +n/a/-15.0 psf Other: Per UL580 test over 15/32" Plywood w/ fasteners at 16" on centers with Safety Factor of 2.0 |
Installation Instructions FL42026_R1_II_T336-22.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL42026_R1_TR_T336-22.pdf |
|
|
| 42026.3 |
Georgia Rib Roof Panel |
26 ga Georgia Rib w/ Wood Purlins over 7/16" OSB |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +n/a/-153.5 Other: Per UL580 / UL1897 test over wood purlins spaced at 2' on centers over 7/16" OSB with Safety Factor of 2.0 |
Installation Instructions FL42026_R1_II_T333-22.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL42026_R1_TR_T333-22.pdf |
|
|
| 42026.4 |
Georgia Rib Roof Panel |
29 ga Georgia Rib w/ Wood Purlins over 7/16" OSB |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +n/a/-116.0 Other: Per UL580 / UL1897 test over wood purlins spaced at 2' on centers over 7/16" OSB with Safety Factor of 2.0 |
Installation Instructions FL42026_R1_II_T334-22.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL42026_R1_TR_T334-22.pdf |