| 48166.1 |
PAC150 Series Roof Panel |
24 Ga. Steel Roof Panels, 1 1/2" Mechanical Seam x 18" Wide (max), over 22 Ga. Steel B-Deck. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +NA/-134.75 Other: Requires 24 ga. steel clips, 2" long and spaced 24" max o.c, fastened to B-Deck with (2) #12 PHSM screws. |
Installation Instructions FL48166_R1_II_s9866.03-450-18-r0.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - West Palm Beach, FL Test Reports FL48166_R1_TR_PAC-150 TAS-100-13-852.pdf FL48166_R1_TR_s9866.03-450-18-r0.pdf |
|
|
| 48166.2 |
PAC150 Series Roof Panel |
24 Ga. Steel Roof Panels, 1 1/2" Mechanical Seam x 18" Wide (max), over 22 Ga. Steel B-Deck. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +NA/-161 Other: Requires 24 ga. steel clips, 2" long and spaced 6" max o.c, fastened to B-Deck with (2) #12 PHSM Screws. |
Installation Instructions FL48166_R1_II_s9866.03-450-18-r0.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - West Palm Beach, FL Test Reports FL48166_R1_TR_PAC-150 TAS-100-13-852.pdf FL48166_R1_TR_s9866.03-450-18-r0.pdf |
|
|
| 48166.3 |
PAC150 Series Roof Panel |
0.032" Aluminum Roof Panels, 1 1/2" Mechanical Seam x 18" Wide (max), over 22 Ga. Steel B-Deck. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +NA/-108.5 Other: Requires 24 ga. steel clips, 2" long and spaced 24" max o.c, fastened to B-Deck with (2) #12 PHSM screws. |
Installation Instructions FL48166_R1_II_s9866.01-450-18-r0.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - West Palm Beach, FL Test Reports FL48166_R1_TR_PAC-150 TAS-100-13-852.pdf FL48166_R1_TR_s9866.01-450-18-r0.pdf |
|
|
| 48166.4 |
PAC150 Series Roof Panel |
0.032" Aluminum Roof Panels, 1 1/2" Mechanical Seam x 18" Wide (max), over 22 Ga. Steel B-Deck. |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +NA/-221 Other: Requires 24 ga. steel clips, 2" long and spaced 6" max o.c, fastened to B-Deck with (2) #12 PHSM screws. |
Installation Instructions FL48166_R1_II_s9866.01-450-18-r0.pdf Verified By: Architectural Testing, Inc. (an Intertek company) - West Palm Beach, FL Test Reports FL48166_R1_TR_PAC-150 TAS-100-13-852.pdf FL48166_R1_TR_s9866.01-450-18-r0.pdf |