Product Approval Menu > Application Detail
 
FL # FL39466-R1
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Elite Metal Manufacturing, LLC
Address/Phone/Email 10121 88th Trace
Live Oak, FL 32064
(386) 688-3627
kyle@lawyerkyle.com
 
Authorized Signature Kyle McLeod
kyle@lawyerkyle.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Roofing
Subcategory Metal Roofing
 
Compliance Method Test Report
 
Testing Lab Farabaugh Engineering and Testing, LLC
Quality Assurance Entity Farabaugh Engineering and Testing, LLC
Quality Assurance Contract Expiration Date 03/25/2031
Validated By Steven M. Urich, PE
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL39466_R1_COI_FETCOIElite.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E1592-052017
 
Equivalence of Product Standards
Certified By

Approved Testing Lab
FL39466_R1_Equiv_FETEQE1592.pdf
 
 
 
 
Product Approval Method Method 1 Option B
 
Date Submitted 01/09/2024
Date Validated 01/09/2024
Date Pending FBC Approval 01/17/2024
Date Approved 04/16/2024
 
Summary of Products
FL # Model, Number or Name Description
39466.1 Elite Rib Roof Panel 29 ga Elite Rib Roof Panel Over Open Framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +22.1/-20.8
 Other: Per ASTM E1592 Test over 18 ga open framing supports located at 5' on centers with safety factor of 2.0 . Materials and Installation shall be per Sections 1506 and 1507.4 of the 2023 FBC Building Code.
Installation Instructions
 FL39466_R1_II_T211-21.pdf
 Verified By: Farabaugh Engineering and Testing, LLC
Test Reports
 FL39466_R1_TR_T211-21.pdf
 FL39466_R1_TR_T213-21.pdf
39466.2 Elite Rib Roof Panel 29 ga Elite Rib Roof Panel Over Open Framing
Limits of Use
 Approved for use in HVHZ: No
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +41.6/-31.2
 Other: Per ASTM E1592 Test over 18 ga open framing supports located at 4' on centers with Safety Factor of 2.0. Materials and Installation shall be per Sections 1506 and 1507.4 of the 2023 FBC Building Code.
Installation Instructions
 FL39466_R1_II_T201-21.pdf
 Verified By: Farabaugh Engineering and Testing, LLC
Test Reports
 FL39466_R1_TR_T201-21.pdf
 FL39466_R1_TR_T213-21.pdf
 