| 21420.1 |
1150/1150S |
1150S Casement
Mulled to
1150 fixed |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: E-Missile rated
Insulated Glass: (Outboard to Inboard)
1/4" H.S. x 3/8" Air Space x 3/16" H.S./0.090" Kuraray Sentry Glass Laminate\ 3/16" H.S. (Large Lite)
1/4" H.S. x 3/8" Air Space x 3/16" H.S./0.180" Kuraray Sentry Glass Laminate/ 3/16" H.S. (Small Lite) |
Certification Agency Certificate FL21420_R3_C_CAC_AAMA_1150_COFX_AW_PG70_C_Impact.pdf Quality Assurance Contract Expiration Date 12/03/2023 Installation Instructions FL21420_R3_II_1150_1150S_FX_CO_Install_SnapTrim_2020.pdf Verified By: Kenneth Snader 40286 (VA) Created by Independent Third Party: Yes Evaluation Reports FL21420_R3_AE_1150_1150S_CO_FX_Impact_Eval_Report_2020.pdf Created by Independent Third Party: Yes |
|
|
| 21420.2 |
1150/1150S |
1150S Casement Mulled to 1150 Fixed with Human Impact Sash Mounted Inboard |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: E-Missile rated
Insulated Glass: (Outboard to Inboard)
1/4" H.S. x 3/8" Air Space x 3/16" H.S./0.090" Kuraray Sentry Glass Laminate\ 3/16" H.S. (Large Lite)
1/4" H.S. x 3/8" Air Space x 3/16" H.S./0.180" Kuraray Sentry Glass Laminate/ 3/16" H.S. (Small Lite) |
Certification Agency Certificate FL21420_R3_C_CAC_WWC 1150 Casement and Picture 450 assembly 506 AW PG70 95x83 plus5.pdf Quality Assurance Contract Expiration Date 12/03/2023 Installation Instructions FL21420_R3_II_WKH - 2106163 - 1150-1150S FX-CO Installation with Human Impact - Stamped Drawings 2022 08 18 08-23-2022.pdf Verified By: Fenestration and Glazing Industry Alliance (formerly AAMA) Created by Independent Third Party: Evaluation Reports FL21420_R3_AE_WKH - 2106163 - 1150 CO-FX Impact_Human Impact Stamped Eval Report 2022 08 16 08-23-2022.pdf Created by Independent Third Party: Yes |