| 48463.1 |
01 W5-09 W-1B899: Reserve Collection RHxx, RRxx, RCxx |
Reserve Wood Single-Car (up to 9’0” wide) WINDCODE® W5 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +32/-36 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC). |
Installation Instructions FL48463_R0_II_102466-Rev07.pdf FL48463_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL48463_R0_AE_CCER_260928-A-00.pdf Created by Independent Third Party: No |
|
|
| 48463.2 |
02 W5-18 W-1B899: Reserve Collection RHxx |
Reserve Wood Double-Car (9’2” To 18’0” wide) WINDCODE® W5 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +32/-36 Other: Doors with standard glazing meet the wind load requirements of the building code but DO NOT meet the impact resistant requirement for windborne debris regions. |
Installation Instructions FL48463_R0_II_105116-Rev02.pdf FL48463_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL48463_R0_AE_CCER_260928-A-00.pdf Created by Independent Third Party: No |
|
|
| 48463.3 |
03 W6-09 W-1G899: Custom Reserve Collection CRD, CR800 |
Custom Wood Single-Car (up to 9’0” wide) WINDCODE® W6 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +39/-45 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC). |
Installation Instructions FL48463_R0_II_102833-Rev05.pdf FL48463_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL48463_R0_AE_CCER_260928-A-00.pdf Created by Independent Third Party: No |
|
|
| 48463.4 |
04 W6-10 W-1G899: Custom Reserve Collection CRDnnn, CR800, MR800, CH900 |
Custom Wood Single-Car (up to 10’0” wide) WINDCODE® W6 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +36.5/-40.5 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC). |
Installation Instructions FL48463_R0_II_104700-Rev01.pdf FL48463_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: JAMES D. WHEELER FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL48463_R0_AE_CCER_260928-A-00.pdf Created by Independent Third Party: No |
|
|
| 48463.5 |
05 W7-09 W-1G899: Custom Reserve Collection CRDnnn, CR800, MR800, CH900 |
Custom Wood Single-Car (up to 9’0” wide) WINDCODE® W7 Garage Door
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +45/-50 Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.2 FBC). |
Installation Instructions FL48463_R0_II_104699-Rev01.pdf FL48463_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: JAMES D. WHEELER FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL48463_R0_AE_CCER_260928-A-00.pdf Created by Independent Third Party: No |
|
|
| 48463.6 |
06 W7-16 W-1G899: Custom Reserve Collection CR800, MR800, CH800, CRDnnn |
Custom Wood Double-Car (9'2" up to 16’2” wide) WINDCODE® W7 Garage Door
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +41/-48 Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact). |
Installation Instructions FL48463_R0_II_104998-IBC-Rev02.pdf FL48463_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL48463_R0_AE_CCER_260928-A-00.pdf Created by Independent Third Party: No |
|
|
| 48463.7 |
07 W8-09 W-1G899: Custom Reserve Collection CR800, MR800, CH800, CRDnnn |
Custom Wood Single-Car (up to 9’0” wide) WINDCODE® W8 Garage Door
|
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +47/-55 Other: Max. Wind Speed (V_ult): 170 MPH. Solid doors or doors with optional impact-resistant glazing are impact-resistant (large missile impact). |
Installation Instructions FL48463_R0_II_104939-IBC-Rev03.pdf FL48463_R0_II_Anchor_Requirements_for_Installation_in_Saltwater_Coastline_areas - JDW 260831.pdf Verified By: James D. Wheeler FL PE 91932 Created by Independent Third Party: No Evaluation Reports FL48463_R0_AE_CCER_260928-A-00.pdf Created by Independent Third Party: No |