Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL47628
Application Type New
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer HEXcores
Address/Phone/Email 1900 7th Street Unit B
Richmond, CA 94801
(703) 906-2589
jeremiah@hexcores.com
 
Authorized Signature Jeremiah Johnson
jeremiah@hexcores.com
 
Technical Representative Jeremiah Johnson
Address/Phone/Email 1900 7th Street Unit B
Richmond, CA 94801
(703) 906-2598
jeremiah@hexcores.com
 
Quality Assurance Representative Jeremiah Johnson
Address/Phone/Email 1900 7th Street Unit B
Richmond, CA 94801
(703) 906-2598
jeremiah@hexcores.com
 
Category Exterior Doors
Subcategory Swinging Exterior Door Assemblies
 
Compliance Method Test Report
 
Testing Lab Architectural Testing, Inc. (an Intertek company) - Fresno, CA
Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date 12/31/2026
Validated By Lucas A. Turner, P.E., MBA
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL47628_R0_COI_Certificate of Independence Florida.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
TAS 2011994
TAS 2021994
TAS 2031994
 
Equivalence of Product Standards
Certified By

 
 
 
 
Product Approval Method Method 1 Option B
 
Date Submitted 07/15/2025
Date Validated 08/23/2025
Date Pending FBC Approval 08/28/2025
Date Approved 10/14/2025
 
Summary of Products
FL # Model, Number or Name Description
47628.1 Pivot Door Pivot Door, 96" wide x 216" tall
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: Yes
 Design Pressure: +60/-60
 Other: Meets Chapter 16 Florida Building Code requirements for High Velocity Hurricane Zone
Installation Instructions
 FL47628_R0_II_s4122.01-301-18-r1.pdf
 Verified By: Architectural Testing, Inc. (an Intertek company) - Fresno, CA
Test Reports
 FL47628_R0_TR_s4122.01-301-18-r1.pdf
 
Back   Next
 