FL # FL33449-R3
Application Type Revision
Code Version 2023
Application Status Approved
  *Approved by DBPR. Approvals by DBPR shall be reviewed and ratified by the POC and/or the Commission if necessary.
 
Comments
Archived
 
Product Manufacturer Resysta North America, Inc.
Address/Phone/Email 4035 Cheyenne Court
Chino, CA 91710
(909) 590-0121
info@resystausa.com
 
Authorized Signature Michael Sloup
michael.sloup@resysta.com
 
Technical Representative Michael Sloup
Address/Phone/Email 4035 Cheyenne Ct.
Chino, CA 91710
(909) 393-2888
Michael.Sloup@resysta.com
 
Quality Assurance Representative Michael Sloup
Address/Phone/Email 4035 Cheyenne Ct.
Chino, CA 91710
(909) 393-2888
Michael.Sloup@resysta.com
 
Category Panel Walls
Subcategory Siding
 
Compliance Method Evaluation Report from a Product Evaluation Entity
 
Evaluation Entity Intertek Testing Services NA, Inc.
Quality Assurance Entity Intertek Testing Services NA, Inc. - QA Entity
Quality Assurance Contract Expiration Date 12/31/2026
Validated By Intertek Testing Services NA, Inc.
 
 
Certificate of Independence
 
Referenced Standard and Year (of Standard)
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
1620
1625
1626
2615.2
 
 
 
Product Approval Method Method 2 Option A
 
Date Submitted 02/27/2024
Date Validated 03/01/2024
Date Pending FBC Approval
Date Approved 03/07/2024
Date Revised 10/06/2026
 
Summary of Products
FL # Model, Number or Name Description
33449.1 Resysta 4 Channel Facade Rigid plastic composite sidings
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +136/-136
 Other: Refer to the design pressures, conditions of use, and supporting evidence shown on CCRR-0273
Installation Instructions
 FL33449_R3_II_Resysta_USA_Siding-Installation_Guide-07142021.pdf
 Verified By: Intertek Testing Services NA, Inc.
 Created by Independent Third Party: 
Evaluation Reports
 FL33449_R3_AE_2024-01-23 Resysta CCRR-0273.pdf
33449.2 Resysta 6" Siding Rigid plastic composite sidings
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +126/-126
 Other: Refer to the design pressures, conditions of use, and supporting evidence shown on CCRR-0272
Installation Instructions
 FL33449_R3_II_Siding Installation Guide Resysta rev 09012020.pdf
 Verified By: Intertek Testing Services NA, Inc.
 Created by Independent Third Party: 
Evaluation Reports
 FL33449_R3_AE_2024-01-23 Resysta CCRR-0272.pdf
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex