Florida Building Code Online
Florida Department of Business & Professional Regulation
myFlorida Logo Town Graphic
DBPR Home Button About DBPR Button DBPR Divisions Button Contact DBPR Button
Florida Department of Business & Professional Regulation
Office of the Secretary
Product Approval
USER: Public User
 
Product Approval Menu > Application Detail
 
FL # FL46658-R6
Application Type Revision
Code Version 2023
Application Status Approved
 
Comments
Archived
 
Product Manufacturer Metl-Span, a Nucor Company
Address/Phone/Email 700 State Highway 121 Bypass
Suite 200
Lewisville, TX 75057
(972) 221-6656
ruben.herrera@nucor.com
 
Authorized Signature Chris Scoville
fpa@qualtim.com
 
Technical Representative
Address/Phone/Email
 
Quality Assurance Representative
Address/Phone/Email
 
Category Panel Walls
Subcategory Products Introduced as a Result of New Technology
 
Compliance Method Evaluation Report from a Florida Registered Architect or a Licensed Florida Professional Engineer
Evaluation Report - Hardcopy Received
 
Florida Engineer or Architect Name who developed the Evaluation Report Ryan J Dexter
Florida License PE-69484
Quality Assurance Entity Farabaugh Engineering and Testing, LLC
Quality Assurance Contract Expiration Date 12/31/2099
Validated By Justin M Lanier, P.E.
  Validation Checklist - Hardcopy Received
 
Certificate of Independence FL46658_R6_COI_260311_ENG-2505-321.01_FPA_CF Wall Sealed.pdf
 
Referenced Standard and Year (of Standard)
StandardYear
ASTM E283/E283M2019
ASTM E3302014
ASTM E3312016
ASTM E842018
NFPA 2592018
NFPA 2852019
NFPA 2862019
 
Equivalence of Product Standards
Certified By

 
Sections from the Code
 
 
 
Product Approval Method Method 1 Option D
 
Date Submitted 03/17/2026
Date Validated 04/07/2026
Date Pending FBC Approval 04/11/2026
Date Approved 06/10/2026
Date Revised 10/02/2026
 
Summary of Products
FL # Model, Number or Name Description
46658.1 CF Wall Panel with PIR Core A composite metal sandwich panel consisting of a continuously foamed-in-place PIR form plastic insulation core between steel facings
Limits of Use
 Approved for use in HVHZ: Yes
 Approved for use outside HVHZ: Yes
 Impact Resistant: No
 Design Pressure: +233/-233
 Other:  
Installation Instructions
 FL46658_R6_II_260401_24-DrJ-0080.FPA-CF_HVHZ_FPA_Sealed.pdf
 FL46658_R6_II_260401_ENG-2505-321.01_FPA_CF Wall_FPA_Sealed.pdf
 FL46658_R6_II_260401_ENG-2508-309_Tuff Wall_FPA_Sealed.pdf
 Verified By: DrJ Engineering, LLC
 Created by Independent Third Party: 
Evaluation Reports
 FL46658_R6_AE_260401_24-DrJ-0080.FPA-CF_HVHZ_FPA_Sealed.pdf
 FL46658_R6_AE_260401_ENG-2505-321.01_FPA_CF Wall_FPA_Sealed.pdf
 FL46658_R6_AE_260401_ENG-2508-309_Tuff Wall_FPA_Sealed.pdf
 Created by Independent Third Party: Yes
 
Back   Next
 
Contact Us :: 2601 Blair Stone Road, Tallahassee FL 32399 Phone: 850-487-1824
Product Approval Accepts:
Visa Mastercard Discover eCheck Amex