| 34027.1 |
Apex Series™ Concealed Fastened Wall Panels |
AP1-1212 or AP1-1653 - Min 24 ga., max 16" wide, 1" deep concealed fastened wall panels |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +120/-70 Other: Maximum outward of 70 psf at clip spacing of 2' for AP1-1653 panels |
Installation Instructions FL34027_R2_II_EvaluationReportC3060_1.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL34027_R2_AE_EvaluationReportC3060_1.pdf Created by Independent Third Party: Yes |
|
|
| 34027.2 |
Board and Batten Series Panels |
Min 24 ga. ,0.75” high, 10” wide coverage BBD75-1010 and 12” wide coverage BBD75-1212 direct fastened panels and 11” wide coverage BB75-1111 clip fastened panels. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +149.6/-77 Other: Max. outward load in 16 ga. steel supports spaced at 24" o.c. is 77.0 psf. |
Installation Instructions FL34027_R2_II_EvaluationReportC3060_2.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL34027_R2_AE_EvaluationReportC3060_2.pdf Created by Independent Third Party: Yes |
|
|
| 34027.3 |
Contempra Series™ Concealed Fastened Wall Panels |
CN88-1212 or CN88-1653 - Min 24 ga., max 16" wide, 7/8" deep concealed fastened wall panels |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +120/-102.5 Other: Maximum outward of 102.5 psf at clip spacing of 2' for CN88-1212 panels |
Installation Instructions FL34027_R2_II_EvaluationReportC3060_3.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL34027_R2_AE_EvaluationReportC3060_3.pdf Created by Independent Third Party: Yes |
|
|
| 34027.4 |
Empire Series™ EM1 CF Wall Panels |
EM1-1212, EM1-1653, EM1-124 or EM1-168 - Min 24 ga., max 16" wide, 1" deep concealed fastened wall panels |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +120/-81.8 Other: Maximum outward load of 81.8 psf at clip spacing of 2' for EM1-1212 panels |
Installation Instructions FL34027_R2_II_EvaluationReportC3060_4.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL34027_R2_AE_EvaluationReportC3060_4.pdf Created by Independent Third Party: Yes |
|
|
| 34027.5 |
Empire Series™ EM15 CF Wall Panels |
EM15-1266, EM15-1275, EM15-1284, EM15-1293, EM15-1210, EM15-1211, EM15-126 or EM15-168 - Min 24 ga., max 16" wide, 1.5" deep concealed fastened wall panels |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +120/-106 Other: Maximum outward load of 106 psf at clip spacing of 2' for EM15-1293 panels |
Installation Instructions FL34027_R2_II_EvaluationReportC3060_5.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL34027_R2_AE_EvaluationReportC3060_5.pdf Created by Independent Third Party: Yes |
|
|
| 34027.6 |
Empire Series™ EM15-1222 CF Wall Panels |
EM15-1222, EM15-1262, EM15-1226, EM15-1224, EM15-262 or EM15-622 - Min 24 ga., max 12" wide, 1.5" deep concealed fastened wall panels |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +120/-80 Other: Maximum outward load of 80 psf at clip spacing of 2' for EM15-1222 panels |
Installation Instructions FL34027_R2_II_EvaluationReportC3060_6.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL34027_R2_AE_EvaluationReportC3060_6.pdf Created by Independent Third Party: Yes |