| 39594.1 |
Elite Rib Wall Panel |
29 ga Elite Rib Wall Panel Over Open Framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +55.4/-41.6 Other: Per ASTM E330 tests over 18 ga open framing supports located at 4' on centers with Safety Factor of 1.5 . Materials and installation shall be per Sections 1403, 1404 and 1405 of the 2023 FBC Building Code. |
Installation Instructions FL39594_R1_II_T202-21.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL39594_R1_TR_T202-21.pdf |
|
|
| 39594.2 |
Elite Rib Wall Panel |
29 ga Elite RIb Wall Panel Over Open Framing |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +29.4/-27.7 Other: Per ASTM E330 tests over 18 ga open framing supports located at 5' on centers with a Safety Factor of 1.5 . Materials and installation shall be per Sections 1403, 1404 and 1405 of the 2023 FBC Building Code. |
Installation Instructions FL39594_R1_II_T212-21.pdf Verified By: Farabaugh Engineering and Testing, LLC Test Reports FL39594_R1_TR_T212-21.pdf |