| 11968.1 |
0.040" Bertha Aluminum Storm Panel (2.25" Deep)- Non-HVHZ - Drawing Number 23-144 |
Corrugated aluminum storm panels retained or not by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile. Max. span is 12'-0" for +25, -25 p.s.f. and 4'-0" for +125, -130 p.s.f. for sections 1, 3, 4, 6, 7, 8, 8A, 9 and 11. See sheet 10 of installation drawing for other spans and pressures. |
Installation Instructions FL11968_R6_II_Drawing23-144.pdf Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL11968_R6_AE_PE Report Drawing 23-144.pdf Created by Independent Third Party: Yes |
|
|
| 11968.2 |
0.050" Bertha Aluminum Storm Panel (2.25" Deep)- Non-HVHZ - Drawing Number 23-166 |
Corrugated aluminum storm panels retained or not by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile. Max. span is 12'-11" for +30, -30 p.s.f. and 8'-2" for +75, -80 p.s.f. for mountings without "h" header. See sheet 5 of installation drawing for other spans and pressures. |
Installation Instructions FL11968_R6_II_Drawing 23-166.pdf Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL11968_R6_AE_Product Evaluation Report Drawing 23-166.pdf Created by Independent Third Party: Yes |
|
|
| 11968.3 |
24 Gage Galvanized Bertha Steel Storm Panel (2.25" Deep)- Non-HVHZ - Drawing Number 23-160 |
corrugated galvanized steel storm panels retained or not by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile. Max. span is 9'-8" for +35, -40 p.s.f. and 7'-2" for +70, -80 p.s.f. for panels mounted without "H" header. See sheet 4 of installation drawing for other spans and pressures. |
Installation Instructions FL11968_R6_II_Drawing 23-160.pdf Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL11968_R6_AE_Product Evaluation Report Drawing 23-160.pdf Created by Independent Third Party: Yes |
|
|
| 11968.4 |
Clear Bertha Storm Panels (2 1/4") - Drawing Number 23-165 |
corrugated polycarbonate storm panels retained or not by tracks to provide hurricane protection. |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: N/A Other: Large Missile. Max/ span is 10'-0" for +28, -28 p.s.f. A.S.D. and 4'-0" for +105, -110 p.s.f. A.S.D desgin load. See sheet 3 of installation drawings for other spans and pressures. |
Installation Instructions FL11968_R6_II_Drawing 23-165.pdf Verified By: American Test Lab of South Florida, Inc. Created by Independent Third Party: Yes Evaluation Reports FL11968_R6_AE_Product Evaluation Report Drawing 23-165.pdf Created by Independent Third Party: Yes |