| 15195.1 |
Batten-Tite⢠Panel System |
Aluminum Pan & Batten System with max. 34.5" wide coverage and 2" tall seams |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-52.5 Other: Uplift load of 52.5 psf with base channel fastened at 12" o.c. |
Installation Instructions FL15195_R4_II_EvaluationReportC2690_1.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL15195_R4_AE_EvaluationReportC2690_1.pdf Created by Independent Third Party: Yes |
|
|
| 15195.2 |
Series 300 Aluminum Panel |
0.04" thick, 12" wide panel fastened to steel deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-210 Other: 180 psf with 16 ga. clip spaced at 18" o.c. and 210 psf with extruded aluminum continuous clip fastened at 18" o.c. |
Installation Instructions FL15195_R4_II_EvaluationReportC2690_2.pdf Verified By: Bala Sockalingam P.E. 62240 Created by Independent Third Party: Yes Evaluation Reports FL15195_R4_AE_EvaluationReportC2690_2.pdf Created by Independent Third Party: Yes |
|
|
| 15195.3 |
Series 300 Steel Panel |
22 ga., 12" wide panel fastened to steel deck |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +N/A/-285 Other: 210 psf with 16 ga. clip spaced at 18" o.c. and 285 psf with extruded aluminum continuous clip fastened at 18" o.c. |
Installation Instructions FL15195_R4_II_EvaluationReportC2690_3.pdf Verified By: Bala Sockalingam P.E. 62240 Created by Independent Third Party: Yes Evaluation Reports FL15195_R4_AE_EvaluationReportC2690_3.pdf Created by Independent Third Party: Yes |