| 8687.1 |
Board and Batten Siding Panel |
Min 26 ga., max 10" wide, 1/2" deep concealed fastened wall panels |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +N/A/-33 Other: Maximum outward load of 33 psf at fastener spacing of 2' o.c. |
Installation Instructions FL8687_R7_II_EvaluationReportC3047_3.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL8687_R7_AE_EvaluationReportC3047_3.pdf Created by Independent Third Party: Yes |
|
|
| 8687.2 |
G-Rib Panel |
Min. 29 ga., 36" wide wall panel over wood supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +70/-70 Other: Inward and outward design load of 70 psf at support spacing of 36" o.c. |
Installation Instructions FL8687_R7_II_EvaluationReportC3047_4.pdf Verified By: Bala Sockalingam 62240 Created by Independent Third Party: Yes Evaluation Reports FL8687_R7_AE_EvaluationReportC3047_4.pdf Created by Independent Third Party: Yes |
|
|
| 8687.3 |
R Panel |
Min. 26 ga., 36" wide wall panel over wood supports |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: No Design Pressure: +40/-40 Other: Inward and outward design load of 40 psf at support spacing of 60" o.c. |
Installation Instructions FL8687_R7_II_EvaluationReportC3047_5.pdf Verified By: Bala Sockalingam PE 62240 Created by Independent Third Party: Yes Evaluation Reports FL8687_R7_AE_EvaluationReportC3047_5.pdf Created by Independent Third Party: Yes |