| 5678.1 |
01 W4-09 C-DSIE-1F173: 3201, 3203, 250, 250G |
Double-skin Insulated (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, up to 9’0” wide |
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +28 PSF/-29 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). |
Installation Instructions FL5678_R8_II_101758-Rev10.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL5678_R8_AE_CCER_230725.pdf Created by Independent Third Party: No |
|
|
| 5678.2 |
02 W4-16 C-DSIE-1F173: 3201, 3203, 250, 250G |
Double-skin Insulated (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, 9’2” to 16’0” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25.5 PSF/-25.5 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). |
Installation Instructions FL5678_R8_II_101760-Rev08.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL5678_R8_AE_CCER_230725.pdf Created by Independent Third Party: No |
|
|
| 5678.3 |
03 W4-09 C-PAN-2F141: 692, 652V |
Steel Pan (min. 24 ga.) WINDCODE® W4 Sectional Door, up to 9’0” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-32 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). |
Installation Instructions FL5678_R8_II_101762-Rev10_s.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL5678_R8_AE_CCER_230725.pdf Created by Independent Third Party: No |
|
|
| 5678.4 |
04 W4-16 C-PAN-2F141: 692, 652V |
Steel Pan (min. 24 ga.) WINDCODE® W4 Sectional Door, 9’2” to 16’0” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +24 PSF/-24.5 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC). |
Installation Instructions FL5678_R8_II_101781-Rev09.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL5678_R8_AE_CCER_230725.pdf Created by Independent Third Party: No |
|
|
| 5678.5 |
05 W4-12 C-DSIE-1F447: 3200, 3220, 240, 240G |
Double-skin Insulated (exterior skin 24 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, up to 10’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-28 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC).
|
Installation Instructions FL5678_R8_II_101687-Rev11.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL5678_R8_AE_CCER_230725.pdf Created by Independent Third Party: No |
|
|
| 5678.6 |
06 W4-20 C-DSIE-1F447: 3200, 3220, 240, 240G |
Double-skin Insulated (exterior skin 24 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, 10’4” to 20’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-28 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC).
|
Installation Instructions FL5678_R8_II_DISCONTINUED_FL5678.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL5678_R8_AE_DISCONTINUED_FL5678.pdf Created by Independent Third Party: No |
|
|
| 5678.7 |
07 W4-24 C-DSIE-1F447: 3200, 3220, 240, 240G |
Double-skin Insulated (exterior skin 24 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, 20’4” to 24’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-25 PSF Other: This Clopay Garage Door with C-channel reinforcements has been discontinued and replaced by a version with T-strut reinforcements.
Contact Clopay customer service for T-strut Approval Numbers and Drawings.
|
Installation Instructions FL5678_R8_II_DISCONTINUED_FL5678.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL5678_R8_AE_DISCONTINUED_FL5678.pdf Created by Independent Third Party: No |
|
|
| 5678.8 |
08 W4-10 C-DSIU-1D477: 3717, C7X17, 3718, C7X18, 3720, C7X20, 240U, 3722, C0X22 |
Double-skin Insulated (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W4 Sectional Door, up to 10’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-25 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC).
|
Installation Instructions FL5678_R8_II_104040-Rev05.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL5678_R8_AE_CCER_230725.pdf Created by Independent Third Party: No |
|
|
| 5678.9 |
09 W4-12 C-PAN-1E458: 525, 525V, 525S, 524, 524V, 524S, 520, 520S, 225, 225S, 224, 224S, C5EST, C5ST, C5ESV, C5SV, C5ESS, C5SS, C4ST C4SV, C4SS, C0ST, C0SS |
Ribbed Steel (min. 25 ga.) WINDCODE® W4 Sectional Door, up to 12’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-25 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC).
|
Installation Instructions FL5678_R8_II_101856-Rev13.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL5678_R8_AE_CCER_230725.pdf Created by Independent Third Party: No |
|
|
| 5678.10 |
10 W4-16 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224S, C4ST C4SV, C4SS, C0ST, C0SS |
Ribbed Steel (min. 24 ga.) WINDCODE® W4 Sectional Door, 12’4” to 16’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-25 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC).
|
Installation Instructions FL5678_R8_II_DISCONTINUED_FL5678.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL5678_R8_AE_DISCONTINUED_FL5678.pdf Created by Independent Third Party: No |
|
|
| 5678.11 |
11 W4-20 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224S, C4ST C4SV, C4SS, C0ST, C0SS |
Ribbed Steel (min. 24 ga.) WINDCODE® W4 Sectional Door, 16’4” to 20’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-25 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC).
|
Installation Instructions FL5678_R8_II_DISCONTINUED_FL5678.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL5678_R8_AE_DISCONTINUED_FL5678.pdf Created by Independent Third Party: No |
|
|
| 5678.12 |
12 W4-24 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224S, C4ST C4SV, C4SS, C0ST, C0SS |
Ribbed Steel (min. 24 ga.) WINDCODE® W4 Sectional Door, 20’4” to 24’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-25 PSF Other: This Clopay Garage Door with C-channel reinforcements has been discontinued and replaced by a version with T-strut reinforcements.
Contact Clopay customer service for T-strut Approval Numbers and Drawings.
|
Installation Instructions FL5678_R8_II_DISCONTINUED_FL5678.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL5678_R8_AE_DISCONTINUED_FL5678.pdf Created by Independent Third Party: No |
|
|
| 5678.13 |
13 W4-24 C-AL-1F499: 902, 903, C2AL, C3AL |
Service Station WINDCODE® W4 Sectional Door, up to 24’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +25 PSF/-25 PSF Other: This Clopay Garage Door with C-channel reinforcements has been discontinued and replaced by a version with T-strut reinforcements.
Contact Clopay customer service for T-strut Approval Numbers and Drawings.
|
Installation Instructions FL5678_R8_II_DISCONTINUED_FL5678.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL5678_R8_AE_DISCONTINUED_FL5678.pdf Created by Independent Third Party: No |
|
|
| 5678.14 |
14 W5-16 C-DSIE-1F447: 3200, 3220, 240, 240G |
Double-skin Insulated (exterior skin 24 ga. min.; interior skin 27 ga. min.) WINDCODE® W5 Sectional Door, up to 16’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +30 PSF/-32 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC).
|
Installation Instructions FL5678_R8_II_200040-Rev15.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL5678_R8_AE_CCER_230725.pdf Created by Independent Third Party: No |
|
|
| 5678.15 |
15 W5-22 C-DSIE-1F447: 3200, 3220, 240, 240G |
Double-skin Insulated (exterior skin 24 ga. min.; interior skin 27 ga. min.) WINDCODE® W5 Sectional Door, 16’4” to 22’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +30 PSF/-30 PSF Other: This Clopay Garage Door with C-channel reinforcements has been discontinued and replaced by a version with T-strut reinforcements.
Contact Clopay customer service for T-strut Approval Numbers and Drawings.
|
Installation Instructions FL5678_R8_II_DISCONTINUED_FL5678.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL5678_R8_AE_DISCONTINUED_FL5678.pdf Created by Independent Third Party: No |
|
|
| 5678.16 |
16 W5-14 C-DSIU-1D477: 3717, C7X17, 3718, C7X18, 3720, C7X20, 240U, 3722, C0X22 |
Double-skin Insulated (exterior skin 27 ga. min.; interior skin 27 ga. min.) WINDCODE® W5 Sectional Door, up to 14’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +30 PSF/-34 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC).
|
Installation Instructions FL5678_R8_II_104044-Rev06.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL5678_R8_AE_CCER_230725.pdf Created by Independent Third Party: No |
|
|
| 5678.17 |
17 W5-08 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224S, C4ST C4SV, C4SS, C0ST, C0SS |
Ribbed Steel (min. 24 ga.) WINDCODE® W5 Sectional Door, up to 8’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +30 PSF/-30 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC).
|
Installation Instructions FL5678_R8_II_101874-Rev13.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL5678_R8_AE_CCER_230725.pdf Created by Independent Third Party: No |
|
|
| 5678.18 |
18 W5-10 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224S, C4ST C4SV, C4SS, C0ST, C0SS |
Ribbed Steel (min. 24 ga.) WINDCODE® W5 Sectional Door, 8’4” to 10’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +30 PSF/-30 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC).
|
Installation Instructions FL5678_R8_II_101875-Rev12.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL5678_R8_AE_CCER_230725.pdf Created by Independent Third Party: No |
|
|
| 5678.19 |
19 W5-12 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224S, C4ST C4SV, C4SS, C0ST, C0SS |
Ribbed Steel (min. 24 ga.) WINDCODE® W5 Sectional Door, 10’4” to 12’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +30 PSF/-30 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC).
|
Installation Instructions FL5678_R8_II_101869-Rev13.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL5678_R8_AE_CCER_230725.pdf Created by Independent Third Party: No |
|
|
| 5678.20 |
20 W5-16 C-PAN-1E448: 524, 524V, 524S, 520, 520S, 224, 224S, C4ST C4SV, C4SS, C0ST, C0SS |
Ribbed Steel (min. 24 ga.) WINDCODE® W5 Sectional Door, 12’4” to 16’2” wide
|
Limits of Use Approved for use in HVHZ: No Approved for use outside HVHZ: Yes Impact Resistant: N/A Design Pressure: +32 PSF/-32 PSF Other: The OPTIONAL glazing available for this product meets the wind load requirements of the building code but DOES NOT meet the impact resistant requirement for windborne debris regions. The product without glazing DOES comply with the impact resistant requirement for windborne debris regions (ref 1609.1.4 FBC).
|
Installation Instructions FL5678_R8_II_DISCONTINUED_FL5678.pdf Verified By: Scott Hamilton FL PE 63286 Created by Independent Third Party: No Evaluation Reports FL5678_R8_AE_DISCONTINUED_FL5678.pdf Created by Independent Third Party: No |