| 3063.1 |
2100(F)WS Exit Device |
Panic or Fire Rated Hardware |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: For use with single outswing, 3' x 7' hollow metal doors & frames |
Certification Agency Certificate FL3063_R17_C_CAC_ZHEM.R21801 - Latching Hardware _ UL Product iQ.pdf Quality Assurance Contract Expiration Date 12/31/2030 Installation Instructions FL3063_R17_II_AADSS1015023.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 3063.2 |
4600LN Series Cylindrical Lockset |
Latching Hardware |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: For use with single inswing/outswing, 3' x 7' hollow metal doors & frames |
Certification Agency Certificate FL3063_R17_C_CAC_ZHEM.R21801 - Latching Hardware _ UL Product iQ.pdf Quality Assurance Contract Expiration Date 12/31/2030 Installation Instructions FL3063_R17_II_AADSS1089504.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 3063.3 |
4700LN Series Cylindrical Lockset |
Latching Hardware |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +50/-50 Other: For use with single inswing/outswing, 3' x 7' hollow metal doors & frames |
Certification Agency Certificate FL3063_R17_C_CAC_ZHEM.R21801 - Latching Hardware _ UL Product iQ.pdf Quality Assurance Contract Expiration Date 12/31/2030 Installation Instructions FL3063_R17_II_AADSS1192039.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 3063.4 |
4800LN Interconnected Lock |
Latching Hardware |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: For use with single inswing, 3' x 7' hollow metal door & frame (latchbolt & deadbolt engaged) |
Certification Agency Certificate FL3063_R17_C_CAC_ZHEM.R21801 - Latching Hardware _ UL Product iQ.pdf Quality Assurance Contract Expiration Date 12/31/2030 Installation Instructions FL3063_R17_II_4800LN InterconnectedLock.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 3063.5 |
5300/5300LN Series Cylindrical Lockset with or without Securitron UNL Unlatch Electromechanical Strike |
Latching Hardware |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: For use with single inswing/outswing, 3' x 7' hollow metal doors & frames |
Certification Agency Certificate FL3063_R17_C_CAC_ZHEM.R21801 - Latching Hardware _ UL Product iQ.pdf Quality Assurance Contract Expiration Date 12/31/2030 Installation Instructions FL3063_R17_II_AADSS1192039.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 3063.6 |
5400/5400LN Series Cylindrical Lockset with 3600 Series Deadbolt or D100 Series Deadbolt |
Latching Hardware |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: For use with single inswing/outswing, 3' x 7' hollow metal doors & frames |
Certification Agency Certificate FL3063_R17_C_CAC_ZHEM.R21801 - Latching Hardware _ UL Product iQ.pdf Quality Assurance Contract Expiration Date 12/31/2030 Installation Instructions FL3063_R17_II_3500, 3600, 3700 AuxDBInstInstruc.pdf FL3063_R17_II_AADSS1089515.pdf FL3063_R17_II_AADSS1193888.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 3063.7 |
5400/5400LN Series Cylindrical Lockset with or without Securitron UNL Unlatch Electromechanical Strike |
Latching Hardware |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: For use with single outswing, 3' x 7' hollow metal doors & frames |
Certification Agency Certificate FL3063_R17_C_CAC_ZHEM.R21801 - Latching Hardware _ UL Product iQ.pdf Quality Assurance Contract Expiration Date 12/31/2030 Installation Instructions FL3063_R17_II_AADSS1089515.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 3063.8 |
6150EDWS, 6150ED(F)WS |
Rim Type Device, 6000 Series |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: For use with single outswing 4' x 8' or pair outswing 8' x 8' hollow metals doors and frames. |
Certification Agency Certificate FL3063_R17_C_CAC_6150ED(F)WS _ Product iQ - Product iQ.pdf FL3063_R17_C_CAC_6150EDWS _ Product iQ - Product iQ.pdf Quality Assurance Contract Expiration Date 12/31/2030 Installation Instructions FL3063_R17_II_80-9460-6000-000_ACC_6100-6150-6200-6250_Exit_Devices_Instr_lo.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 3063.9 |
6170EDWS, 6170ED(F)WS |
Surface Vertical Rod Type Exit Device, 6000 Series |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: For use with single outswing 4' x 8' or pair outswing 8' x 8' hollow metals doors and frames. |
Certification Agency Certificate FL3063_R17_C_CAC_6170ED(F)WS _ Product iQ - Product iQ.pdf FL3063_R17_C_CAC_6170EDWS _ Product iQ - Product iQ.pdf Quality Assurance Contract Expiration Date 12/31/2030 Installation Instructions FL3063_R17_II_80-9460-6005-000_ACC_6170F-6210_SVR_Instr_lo.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 3063.10 |
6250MEDWS, 6250MED(F)WS |
Rim Type Exit Device, 6000 Series |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: For use with single outswing 4' x 8' or pair outswing 8' x 8' hollow metals doors and frames. |
Certification Agency Certificate FL3063_R17_C_CAC_6250MED(F)WS _ Product iQ - Product iQ.pdf FL3063_R17_C_CAC_6250MEDWS _ Product iQ - Product iQ.pdf Quality Assurance Contract Expiration Date 12/31/2030 Installation Instructions FL3063_R17_II_80-9460-6000-000_ACC_6100-6150-6200-6250_Exit_Devices_Instr_lo.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 3063.11 |
7150(F)WS/7250(F)WS Squarebolt Exit Device with or without 500F, 600F Series Trims, or prefixed "Sym" (Symphony Trim) |
Panic or Fire Rated Hardware |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: For use with outswing, 4' x 8' single or 8' x 8' pairs of hollow metal doors & frames (w/M100F, M200FWS, or KRMFWS Mullions) |
Certification Agency Certificate FL3063_R17_C_CAC_ZHEM.R21801 - Latching Hardware _ UL Product iQ.pdf Quality Assurance Contract Expiration Date 12/31/2030 Installation Instructions FL3063_R17_II_AADSS1015066.pdf FL3063_R17_II_AADSS1015072.pdf FL3063_R17_II_AADSS1089690.pdf FL3063_R17_II_AADSS1089697.pdf FL3063_R17_II_AADSS1215574.pdf FL3063_R17_II_SymphonyTrimExitDevices.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 3063.12 |
7150(F)WS/7250(F)WS Squarebolt Exit Device with or without 500F, 600F Series Trims, or prefixed "Sym" (Symphony Trim) |
Panic or Fire Rated Hardware |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +115/-115 Other: For use with single outswing, 3' x 7' hollow metal doors & frames |
Certification Agency Certificate FL3063_R17_C_CAC_ZHEM.R21801 - Latching Hardware _ UL Product iQ.pdf Quality Assurance Contract Expiration Date 12/31/2030 Installation Instructions FL3063_R17_II_AADSS1015066.pdf FL3063_R17_II_AADSS1015072.pdf FL3063_R17_II_AADSS1089690.pdf FL3063_R17_II_SymphonyTrimExitDevices.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 3063.13 |
7150(F)WS/7250(F)WS Squarebolt Exit Device with or without 500F, 600F Series Trims, or prefixed "Sym" (Symphony Trim) |
Panic or Fire Rated Hardware |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: For use with single outswing, 3' x 7' hollow metal doors & frames |
Certification Agency Certificate FL3063_R17_C_CAC_ZHEM.R21801 - Latching Hardware _ UL Product iQ.pdf Quality Assurance Contract Expiration Date 12/31/2030 Installation Instructions FL3063_R17_II_AADSS1015066.pdf FL3063_R17_II_AADSS1015072.pdf FL3063_R17_II_AADSS1089690.pdf FL3063_R17_II_SymTrimExitDevices.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 3063.14 |
7170(F)WS Surface Vertical Rod Exit Device with or without 500F, 600F Series Trims, or prefixed "Sym" (Symphony Trim) |
Panic or Fire Rated Hardware |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: For use with outswing, 4' x 8' single or 8' x 8' pairs of hollow metal doors & frames |
Certification Agency Certificate FL3063_R17_C_CAC_ZHEM.R21801 - Latching Hardware _ UL Product iQ.pdf Quality Assurance Contract Expiration Date 12/31/2030 Installation Instructions FL3063_R17_II_7170(F)WSInstInstruc.pdf FL3063_R17_II_AADSS1089645.pdf FL3063_R17_II_AADSS1089690.pdf FL3063_R17_II_SymphonyTrimExitDevices.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 3063.15 |
7380F Multi-Point Lock |
Latching Hardware |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +150/-150 Other: For use with inswing/outswing, 4' x 8' single or 8' x 8' pairs of hollow metal doors & frames (two 988Y surface bolts engaged on inactive leaf) |
Certification Agency Certificate FL3063_R17_C_CAC_ZHEM.R21801 - Latching Hardware _ UL Product iQ.pdf Quality Assurance Contract Expiration Date 12/31/2030 Installation Instructions FL3063_R17_II_7380Multi-PointLockInstInstruc.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 3063.16 |
82 Series Interconnect Lockset |
Latching Hardware |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: For use with single inswing, 3' x 7' hollow metal door & frame (latchbolt & deadbolt engaged) |
Certification Agency Certificate FL3063_R17_C_CAC_ZHEM.R21801 - Latching Hardware _ UL Product iQ.pdf Quality Assurance Contract Expiration Date 12/31/2030 Installation Instructions FL3063_R17_II_82 and D Series ICL Installation Instructions 2-12-2020.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 3063.17 |
8800 Series and 8800MELR Series Mortise Lock with or without Securitron EPTL Power Transfer |
Latching Hardware |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: For use with single inswing/outswing, 3' x 7' hollow metal doors & frames |
Certification Agency Certificate FL3063_R17_C_CAC_ZHEM.R21801 - Latching Hardware _ UL Product iQ.pdf Quality Assurance Contract Expiration Date 12/31/2030 Installation Instructions FL3063_R17_II_80-9086-0060-010_Accentra8800_MELR_Instr 04-24.pdf FL3063_R17_II_AADSS1014908.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 3063.18 |
8800 Series Mortise Locks, S8800 x Sym Series Mortise Locks (Latchbolt x Deadbolt engaged) |
Latching Hardware |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +70/-70 Other: For use with single inswing/outswing, 3' x 7' hollow metal doors & frames |
Certification Agency Certificate FL3063_R17_C_CAC_ZHEM.R21801 - Latching Hardware _ UL Product iQ.pdf Quality Assurance Contract Expiration Date 12/31/2030 Installation Instructions FL3063_R17_II_AADSS1014908.pdf FL3063_R17_II_S8800FLxSymTrimMortiseLocks.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 3063.19 |
8800 Series Mortise Locks, S8800 x Sym Series Mortise Locks (Latchbolt x Deadbolt engaged) |
Latching Hardware |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +115/-115 Other: For use with single inswing/outswing, 3' x 7' hollow metal doors & frames |
Certification Agency Certificate FL3063_R17_C_CAC_ZHEM.R21801 - Latching Hardware _ UL Product iQ.pdf Quality Assurance Contract Expiration Date 12/31/2030 Installation Instructions FL3063_R17_II_AADSS1014908.pdf FL3063_R17_II_S8800FLxSymTrimMortiseLocks.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |
|
|
| 3063.20 |
8800 Series Mortise Lockset with or without Securitron MUNL Unlatch Electromechanical Strike |
Latching Hardware |
Limits of Use Approved for use in HVHZ: Yes Approved for use outside HVHZ: Yes Impact Resistant: Yes Design Pressure: +60/-60 Other: For use with single outswing, 3' x 7' hollow metal doors & frames |
Certification Agency Certificate FL3063_R17_C_CAC_ZHEM.R21801 - Latching Hardware _ UL Product iQ.pdf Quality Assurance Contract Expiration Date 12/31/2030 Installation Instructions FL3063_R17_II_AADSS1014908.pdf Verified By: UL LLC Created by Independent Third Party: Evaluation Reports Created by Independent Third Party: |